Rishabh
86 Rishabh products listed in this category. For prices and availability, send an enquiry.
Products
-
Enquire about FQ 96
FQ 96 Vibrating Reed Frequency Meter, 96 x 96 mm
Vibrating reed frequency meter, 96 x 96 mm: mechanical resonance reeds show 45...50...55 Hz or 47...50...53 Hz; class 0.5, 110 V to 440 V input, 5 VA or less.
-
Enquire about Optima VAF
Optima VAF Multifunction VAF Panel Meter
Rish Optima VAF digital panel meter for AC voltage, current, frequency and other parameters, with 3 line 3 digit LED display, 3 phase or 1 phase versions and optional limit output.
-
Enquire about PL 48
PL 48 Moving Coil DC Ammeter / Voltmeter, 240°, 48 x 48 mm
Moving coil DC panel meter, 48 x 48 mm, with long 240° scale for better resolution: DC current from µA ranges or DC voltage from mV ranges; class 1.5, interchangeable scales.
-
Enquire about PL 72
PL 72 Moving Coil DC Ammeter / Voltmeter, 240°, 72 x 72 mm
Moving coil DC panel meter, 72 x 72 mm, with long 240° scale for better resolution: DC current from µA ranges or DC voltage from mV ranges; class 1.5, interchangeable scales.
-
Enquire about PL 96
PL 96 Moving Coil DC Ammeter / Voltmeter, 240°, 96 x 96 mm
Moving coil DC panel meter, 96 x 96 mm, with long 240° scale for better resolution: DC current from µA ranges or DC voltage from mV ranges; class 1.5, interchangeable scales.
-
Enquire about PL 144
PL 144 Moving Coil DC Ammeter / Voltmeter, 240°, 144 x 144 mm
Moving coil DC panel meter, 144 x 144 mm, with long 240° scale for better resolution: DC current from µA ranges or DC voltage from mV ranges; class 1.5, interchangeable scales.
-
Enquire about PQ 2in1 96
PQ 2in1 96 Dual Moving Coil DC Meter (2 in 1), 96 x 96 mm
Two moving coil DC meters in one 96 x 96 mm case: any two DC voltage or current parameters, 54 mm scales; class 1.5, 600 V CAT III.
-
Enquire about PQ 2in1 144
PQ 2in1 144 Dual Moving Coil DC Meter (2 in 1), 144 x 144 mm
Two moving coil DC meters in one 144 x 144 mm case: any two DC voltage or current parameters, 54 mm scales; class 1.5, 600 V CAT III.
-
Enquire about PQ 48
PQ 48 Moving Coil DC Ammeter / Voltmeter, 90°, 48 x 48 mm
Moving coil panel meter, 48 x 48 mm, 90° linear scale: DC current from µA ranges or DC voltage from mV ranges, 4-20 mA transducer and shunt versions; class 1.5.
-
Enquire about PQ 72
PQ 72 Moving Coil DC Ammeter / Voltmeter, 90°, 72 x 72 mm
Moving coil panel meter, 72 x 72 mm, 90° linear scale: DC current from µA ranges or DC voltage from mV ranges, 4-20 mA transducer and shunt versions; class 1.5.
-
Enquire about PQ 96
PQ 96 Moving Coil DC Ammeter / Voltmeter, 90°, 96 x 96 mm
Moving coil panel meter, 96 x 96 mm, 90° linear scale: DC current from µA ranges or DC voltage from mV ranges, 4-20 mA transducer and shunt versions; class 1.5.
-
Enquire about PQ 144
PQ 144 Moving Coil DC Ammeter / Voltmeter, 90°, 144 x 144 mm
Moving coil panel meter, 144 x 144 mm, 90° linear scale: DC current from µA ranges or DC voltage from mV ranges, 4-20 mA transducer and shunt versions; class 1.5.
-
Enquire about Saxon 012
Saxon 012 Analog Panel Meter, ANSI Case
Saxon series ANSI case analog meter: true RMS AC ammeters to 60 A and voltmeters to 750 V, DC ammeters and voltmeters, frequency meters and hours run meters; surface or window mounting.
-
Enquire about Saxon 013
Saxon 013 Analog Panel Meter, ANSI Case
Saxon series ANSI case analog meter: true RMS AC ammeters to 60 A and voltmeters to 750 V, DC ammeters and voltmeters, frequency meters and hours run meters; surface or window mounting.
-
Enquire about SQ 96
SQ 96 Electronic Synchroscope, 96 x 96 mm
Electronic synchroscope, 96 x 96 mm: rotating LED vector shows phase and frequency difference between bus and generator for paralleling; 100 V to 500 V inputs, 35-70 Hz.
-
Enquire about SQ 144
SQ 144 Electronic Synchroscope, 144 x 144 mm
Electronic synchroscope, 144 x 144 mm: rotating LED vector shows phase and frequency difference between bus and generator for paralleling; 100 V to 500 V inputs, 35-70 Hz.
-
Enquire about Vista 212
Vista 212 Analog Panel Meter, ANSI 2½ inch Case
RISH Vista 212 analog panel meter in ANSI size 2½ case for AC/DC amps, volts or frequency; high torque pivot and jewel movement, true RMS moving iron types, up to 50 A direct.
-
Enquire about Vista 312
Vista 312 Analog Panel Meter, ANSI 3½ inch Case
RISH Vista 312 analog panel meter in ANSI size 3½ case for AC/DC amps, volts or frequency; high torque pivot and jewel movement, true RMS moving iron types, up to 50 A direct.
-
Enquire about Vista 412
Vista 412 Analog Panel Meter, ANSI 4½ inch Case
RISH Vista 412 analog panel meter in ANSI size 4½ case for AC/DC amps, volts or frequency; high torque pivot and jewel movement, true RMS moving iron types, up to 50 A direct.
-
Enquire about VL 72
VL 72 Moving Coil Rectifier AC Ammeter / Voltmeter, 240°, 72 x 72 mm
Moving coil rectifier AC panel meter, 72 x 72 mm, with long 240° scale: AC voltage or current calibrated in RMS for sine wave, low VA burden; class 1.5.
-
Enquire about VL 96
VL 96 Moving Coil Rectifier AC Ammeter / Voltmeter, 240°, 96 x 96 mm
Moving coil rectifier AC panel meter, 96 x 96 mm, with long 240° scale: AC voltage or current calibrated in RMS for sine wave, low VA burden; class 1.5.
-
Enquire about VL 144
VL 144 Moving Coil Rectifier AC Ammeter / Voltmeter, 240°, 144 x 144 mm
Moving coil rectifier AC panel meter, 144 x 144 mm, with long 240° scale: AC voltage or current calibrated in RMS for sine wave, low VA burden; class 1.5.
-
Enquire about VQ 48
VQ 48 Moving Coil Rectifier AC Ammeter / Voltmeter, 90°, 48 x 48 mm
Moving coil rectifier panel meter, 48 x 48 mm, 90° linear scale: AC voltage to 600 V or AC current from 1 mA, low VA burden, calibrated in RMS for sine wave; class 1.5.
-
Enquire about VQ 72
VQ 72 Moving Coil Rectifier AC Ammeter / Voltmeter, 90°, 72 x 72 mm
Moving coil rectifier panel meter, 72 x 72 mm, 90° linear scale: AC voltage to 600 V or AC current from 1 mA, low VA burden, calibrated in RMS for sine wave; class 1.5.