Schneider Electric PM2230 Power and Energy Meter, LCD, 31st Harmonic, RS485, Class 0.5S

Model number
PM2230

This device is a panel mount or flush mount power meter with a 96mm by 96mm bezel size having backlit LCD display of 128 by 128 pixels.

Price and availability on request

We reply by email or phone, Monday to Saturday, 10:30 am to 6:30 pm.

Several models? Add each to your enquiry list and send them as one enquiry.

Request a quote

Sent with the product details: Schneider Electric PM2230 Power and Energy Meter, LCD, 31st Harmonic, RS485, Class 0.5S.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Bill checking to verify that you are only charged for the energy you use
  • Aggregation of energy consumption and cost allocation within the same facility
  • Energy cost and usage analysis to optimise energy usage
  • Metering of electrical parameters to understand your electrical distribution system

Specifications

Technical
Device applicationPower monitoring, Sub billing
Power quality analysistotal harmonic distortion, up to the 31st harmonic
Accuracy classClass 1 reactive energy conforming to IEC 62053-24, Class 0.5S active energy conforming to IEC 62053-22, Class 5 harmonic distortion (I THD & U THD)
Measurement accuracyApparent power +/- 0.5 %, Active energy +/- 0.5 %, Reactive energy +/- 1 %, Active power +/- 0.5 %, Voltage +/- 0.5 %, Power factor +/- 0.01, Current +/- 0.5 %, Frequency +/- 0.05 %
Measurement current5-6000 mA
Frequency measurement range45-65 Hz
[Us] rated supply voltage80-277 V AC 45-65 Hz +/- 10 %, 100-277 V DC +/- 10 %
Network frequency50 Hz, 60 Hz
Ride-through time50 ms 120 V AC typical, 50 ms 230 V AC typical, 50 ms 125 V DC typical
[In] rated current5 A, 1 A
Maximum power consumption in VA8 VA at 277 V AC
Maximum power consumption in W3.3 W (power lines (AC)), 3.3 W at 277 V (power lines (DC))
Input impedanceCurrent (impedance 5 MOhm)
Display typeBacklit LCD
Display colourMonochrome
Display resolution128 x 128 pixels
Demand intervalsConfigurable from 1 to 60 min
Control type4 x button
Number of inputs0
Number of outputs0
Communication port protocolModbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires, insulation 2500 V
Communication port supportScrew terminal block - RS485
Data recordingPower logs, Min/max for 8 parameters, Energy consumption logs, Time stamping
Function availableReal time clock
Sampling rate64 samples/cycle
CybersecurityEnable/disable communication ports
Communication serviceRemote monitoring
User languagePortuguese, German, Chinese, English, Spanish, French, Russian
Product certificationsCE conforming to IEC 61010-1, CULus conforming to UL 61010-1, CULus conforming to CSA C22.2 No 61010-1, RCM, EAC, C-Tick
Mounting modeClip-on
Mounting positionVertical
Mounting supportFramework
Measurement categoryCategory III 480 V, Category II 480-600 V
Electrical insulation classDouble insulation, Class II
Connections - terminalsCurrent transformer - screw connection (bottom) 6, Voltage inputs - screw connection (top) 4
MaterialPolycarbonate
Width96 mm
DepthTotal - 76.09 mm, Embedded - 61.64 mm
Height96 mm
Net weight300 g
Targeted countryIndia
Environment
IP degree of protectionIP54 front - conforming to IEC 60529, IP30 body - conforming to IEC 60529
Relative humidity5-95 % at 50 °C
Pollution degree2
Ambient air temperature for operation-10-60 °C
Ambient air temperature for storage-25-70 °C
Operating altitude<= 2000 m
Overvoltage categoryIII

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering. Brand names, logos and model names are trademarks of their respective owners, used only to identify the product. Details

Model numbers in this series (1)

Send us the complete code you need and we will quote it.

  • METSEPM2230D

About the PM2230

This device is a panel mount or flush mount power meter with a 96mm by 96mm bezel size having backlit LCD display of 128 by 128 pixels. The meter measures active energy as per accuracy class Class 0.5S complying to IEC 62053-22 standard with sampling rate of 64 samples per cycle. Able to measures all three vectors of power and energy such as Active, Apparent & Reactive beside Voltages, Current, Frequency and Power Factor. Plus the total Harmonic Distortion and Individual harmonics up to 31st Harmonic order. The meter will function in either 50Hz or 60Hz network frequency and accepts universal control power voltages ranging from 80 to 300 V Line to Neutral AC or DC voltages. Rated current for this meter is either 1A or 5A input. it supports up to 13 different types of wiring schemes under Single Phase, Two Phase or Three Phase configuration types. The range of measurement voltage between Phases is 35 to 480 V Line to Line AC at 45 to 65 Hz while it is 20 to 277 V between Line and Neutral. It is having RS485 communication port over Modbus RTU protocol. The meter can be upgraded with optional add on IO modules for WAGES monitoring. These module comes with either two channels each of digital inputs and outputs or analog inputs and outputs. This version can be configured for 23 different types of alarms stored in 40 registers.

Order code: METSEPM2230D.

Frequently asked questions

What is the Schneider Electric PM2230?

This device is a panel mount or flush mount power meter with a 96mm by 96mm bezel size having backlit LCD display of 128 by 128 pixels.

What is the accuracy of the PM2230?

Accuracy class: Class 1 reactive energy conforming to IEC 62053-24, Class 0.5S active energy conforming to IEC 62053-22, Class 5 harmonic distortion (I THD & U THD); Measurement accuracy: Apparent power +/- 0.5 %, Active energy +/- 0.5 %, Reactive energy +/- 1 %, Active power +/- 0.5 %, Voltage +/- 0.5 %, Power factor +/- 0.01, Current +/- 0.5 %, Frequency +/- 0.05 %.

What is the measuring range of the PM2230?

45-65 Hz.

What supply does the PM2230 need?

80-277 V AC 45-65 Hz +/- 10 %, 100-277 V DC +/- 10 %.

Which model numbers does this page cover?

Besides the PM2230, this page covers METSEPM2230D.