Key features

  • Digital Input, Relay Output ensures compatibility and functionality
  • Conformal coating for protection against environmental factors
  • Energy import and export, energy consumption and generation for energy management
  • Harmonics, includes analysis of up to the 15th harmonic for comprehensive assessment
  • Detailed measurement accuracy thanks to 32 samples per cycle

Specifications

Technical
Power quality analysistotal harmonic distortion
Device applicationEnergy monitoring
Type of measurementCurrent, Voltage, Frequency, Power factor per phase, Power factor average, Power, Energy, Active power demand, Reactive power demand, Apparent power demand, Phase unbalance, Phase angle, RPM
Counter functionsON hour counting, ON-load hour counting, Power interruption
[Us] rated supply voltage48-277 V AC 45-65 Hz, 48-277 V DC
Network frequency50 Hz, 60 Hz
[In] rated current1 A, 5 A
Type of network3P, 2P + N, 1P + N, 3P + N, 2P
Maximum power consumption in VA4 VA at 240 V between phase and neutral
Maximum power consumption in W2 W at 240 V
Display type8 segments LED
Display colourRed
Messages display capacity3 fields of 4 characters
Display digits12 digit(s) - 14.2 mm in height
Communication of dataReading of measurements
Sampling rate32 samples/cycle
Measurement current5-6000 mA
SignalVoltage (impedance 5 MOhm)4 x , Current 0.005-10 A (impedance 0.3 MOhm)6 x
Frequency measurement range45-65 Hz
Accuracy classClass 0.5S active energy conforming to IEC 62053-22, Class 2 reactive energy conforming to IEC 62053-23
Demand intervals1 s
Communication port protocolModbus at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires, insulation 2500 V
Communication port supportScrew connector - RS485
Mounting modeFlush-mounted, Vertical
Mounting supportFramework
Type of installationIndoor installation, Must be permanently connected and fixed
Measurement categoryCategory III 480 V
Electrical insulation classClass II, Double insulation
StandardsIEC 61010-1:ed. 3, UL 61010-1:ed. 3
Product certificationsCE conforming to IEC 61010-1, CULus conforming to UL 61010-1, CULus conforming to CSA C22.2 No 61010-1
Width96 mm
DepthOutside - 13 mm, Panel - 49 mm
Height96 mm
Environment
Overvoltage categoryIII
IP degree of protectionIP51 front - conforming to IEC 60529, IP30 body - conforming to IEC 60529
Relative humidity5-95 %
Pollution degree2
Ambient air temperature for operation-10-60 °C
Ambient air temperature for storage-20-70 °C
Operating altitude<= 2000 m

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering. Brand names, logos and model names are trademarks of their respective owners, used only to identify the product. Details

Model numbers in this series (1)

Send us the complete code you need and we will quote it.

  • METSEPM1125HCCL05

About the PM1125HC

EasyLogic meters PM1125H are advanced replacements for multiple analog meters, making them ideal for stand-alone metering in various applications. Such as custom panels, switchboards, switchgear, genset panels, motor control centers, power factor improvement panels, and OEM panel boards. The meter is associated with a Class 0.5 active energy accuracy level, ensuring good measurements per IEC standards. Same for reactive energy with Class 2.0. The display can simultaneously show three power parameters (Watt, Watt per hour, VoltAmps, VA per hour, va reactif, var per hour). Plus record demand values for power, energy, or reactive energy with selectable parameters and intervals. This meter series measure essential electrical parameters in several panels types, boards, for cost management. Similarly for network management, the meter support THD power quality analysis, demand, power factor, phase angle and more. The device can be connected from 432VAC to 528VAC, 480VAC volts between phases, without needing voltage transformers. Compliant with measurement category III. The meters feature an easy-to-read display with 8-segment alphanumeric LEDs, showing three concurrent values and auto-scrolling capabilities. The compact design allows for tool-free mounting using two retainer clips. For user protection, the case is double insulated. For cybersecurity feature, the user will have options to disable the RS-485 port through front panel keys to prevent unauthorized access. Making the PM1000H suitable for complex communication networks. Cost management features facilitate energy consumption aggregation and cost allocation by area, usage, shift, and time within the same facility.

Order code: METSEPM1125HCCL05.

Frequently asked questions

What is the Schneider Electric PM1125HC?

EasyLogic meters PM1125H are advanced replacements for multiple analog meters, making them ideal for stand-alone metering in various applications.

What is the accuracy of the PM1125HC?

Class 0.5S active energy conforming to IEC 62053-22, Class 2 reactive energy conforming to IEC 62053-23.

What is the measuring range of the PM1125HC?

45-65 Hz.

What supply does the PM1125HC need?

48-277 V AC 45-65 Hz, 48-277 V DC.