Key features

  • SIL2 certified
  • Level, interface and density measurement in one unit
  • Average temperature measurement via external sensor
  • Two density modes: on-demand spot / average, and real-time average using a pressure transmitter
  • Two-wire bus with looping to reduce cabling
  • Automatic level calibration and density-variation compensation
  • Automatic compensation for wire weight and tank deformation
  • Wave integration in level measurement
  • Accepts external current inputs and contacts for control room data
  • Local and remote repeatability checks
  • Field calibration via portable programmer without opening the unit

Specifications

Level
Measuring range0 to 27000 mm standard; 0 to 37000 mm on request
Accuracy±0.6 mm
Sensitivity±0.1 mm
Repeatability±0.1 mm
Specifications
Interface accuracy±2 mm
Resolution1 mm or 0.1 mm (selectable)
Displacer speed2400 mm/min maximum
Displacer diameter90 mm standard; 45 mm and 65 mm optional
Ambient operating temperature-10 to +60 °C standard; -50 to +85 °C optional
Storage temperature-50 to +85 °C
Density accuracy
On demand±0.005 g/cc
Real time±0.08% (with pressure transmitter of ±0.04% of URL)
Temperature
Range-200 to +200 °C
Accuracy±0.2 °C
Resolution0.1 °C
SensorRTD spot / averaging (multi-point), max. 14
LPG mass
Accuracy±1.3% of reading with SG density; ±0.3% of reading with manually entered density
Resolution0.01 metric tonnes

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering. Brand names, logos and model names are trademarks of their respective owners, used only to identify the product. Details

About the 139 M

SIL 2 servo tank gauge measuring product level, interface level, density and temperature, level accuracy ±0.6 mm, range to 27 m (37 m on request), RS-485 multidrop for up to 16 gauges. Typical applications: Inventory control at tank farms; Bulk storage operations; Product level, interface and density monitoring across industries.

Frequently asked questions

What is the SBEM 139 M?

SIL 2 servo tank gauge measuring product level, interface level, density and temperature, level accuracy ±0.6 mm, range to 27 m (37 m on request), RS-485 multidrop for up to 16 gauges.

What is the accuracy of the 139 M?

Accuracy: ±0.6 mm; Interface accuracy: ±2 mm; On demand: ±0.005 g/cc.

What is the measuring range of the 139 M?

Measuring range: 0 to 27000 mm standard; 0 to 37000 mm on request; Range: -200 to +200 °C.

What operating temperature is the 139 M rated for?

-10 to +60 °C standard; -50 to +85 °C optional.