SIL 2 servo tank gauge measuring product level, interface level, density and temperature, level accuracy ±0.6 mm, range to 27 m (37 m on request), RS-485 multidrop for up to 16 gauges.
Price and availability on request
We reply by email or phone, Monday to Saturday, 10:30 am to 6:30 pm.
Several models? Add each to your enquiry list and send them as one enquiry.
Key features
- SIL2 certified
- Level, interface and density measurement in one unit
- Average temperature measurement via external sensor
- Two density modes: on-demand spot / average, and real-time average using a pressure transmitter
- Two-wire bus with looping to reduce cabling
- Automatic level calibration and density-variation compensation
- Automatic compensation for wire weight and tank deformation
- Wave integration in level measurement
- Accepts external current inputs and contacts for control room data
- Local and remote repeatability checks
- Field calibration via portable programmer without opening the unit
Specifications
| Measuring range | 0 to 27000 mm standard; 0 to 37000 mm on request |
|---|---|
| Accuracy | ±0.6 mm |
| Sensitivity | ±0.1 mm |
| Repeatability | ±0.1 mm |
| Interface accuracy | ±2 mm |
|---|---|
| Resolution | 1 mm or 0.1 mm (selectable) |
| Displacer speed | 2400 mm/min maximum |
| Displacer diameter | 90 mm standard; 45 mm and 65 mm optional |
| Ambient operating temperature | -10 to +60 °C standard; -50 to +85 °C optional |
| Storage temperature | -50 to +85 °C |
| On demand | ±0.005 g/cc |
|---|---|
| Real time | ±0.08% (with pressure transmitter of ±0.04% of URL) |
| Range | -200 to +200 °C |
|---|---|
| Accuracy | ±0.2 °C |
| Resolution | 0.1 °C |
| Sensor | RTD spot / averaging (multi-point), max. 14 |
| Accuracy | ±1.3% of reading with SG density; ±0.3% of reading with manually entered density |
|---|---|
| Resolution | 0.01 metric tonnes |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering. Brand names, logos and model names are trademarks of their respective owners, used only to identify the product. Details
About the 139 M
SIL 2 servo tank gauge measuring product level, interface level, density and temperature, level accuracy ±0.6 mm, range to 27 m (37 m on request), RS-485 multidrop for up to 16 gauges. Typical applications: Inventory control at tank farms; Bulk storage operations; Product level, interface and density monitoring across industries.
Frequently asked questions
What is the SBEM 139 M?
SIL 2 servo tank gauge measuring product level, interface level, density and temperature, level accuracy ±0.6 mm, range to 27 m (37 m on request), RS-485 multidrop for up to 16 gauges.
What is the accuracy of the 139 M?
Accuracy: ±0.6 mm; Interface accuracy: ±2 mm; On demand: ±0.005 g/cc.
What is the measuring range of the 139 M?
Measuring range: 0 to 27000 mm standard; 0 to 37000 mm on request; Range: -200 to +200 °C.
What operating temperature is the 139 M rated for?
-10 to +60 °C standard; -50 to +85 °C optional.