Proton MPC-6 GSM Mobile Pump Controller with Starter

Brand
Proton
Model number
MPC-6

Controller for starting and stopping a pump remotely over GSM (Proton MPC-6). Relay output rated 7 A at 250 V.

Price and availability on request

Request a quote

Sent with the product details: Proton MPC-6 GSM Mobile Pump Controller with Starter.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • 1. Fully programmable
  • 2. Suitable for three phase pumps up to 25HP
  • 3. Relay outputs for Star-Delta starters
  • 4. No auxiliary power supply required for controller operation
  • 5. Can be operated in 3 modes such as GSM/AUTO/MANUAL
  • 6. GSM based SMS controlled start/stop and remote monitoring
  • 7. GSM based Interactive Voice Response System (IVRS) controlled start/stop and remote monitoring for 3 registered numbers
  • 8. IVRS – Voice response available in regional language
  • 9. Live Motor operation Status available via SMS as Motor ON/OFF status, Live Fault, phase voltages and current drawn per phase
  • 10. Inbuilt phone book for auto reply in case of faults
  • 11. Complete protection from electrical unhealthy condition
  • 12. All parameters are settable through front key
  • 13. LED indications for alarm (fault) & MOTOR ON
  • 14. Scrolling display of parameters, one by one in scroll mode
  • 15. Three bright 7 segment display on unit
  • 16. Inverse Time trip curve for over load fault
  • 17. It Will give Miss call AT Power ON
  • The Motor protection unit continuously scans the faults like Under Voltage, Over Voltage, SPP, Reverse Phase, Voltage Unbalance, Under Load, Over Load, Current unbalance

Specifications

Specifications
Input Supply3 Phase 415 V, 50 HZ AC (3 Phase 3 wire)
Accuracy1] Voltage 0.25% ± 1 dgts. 2] Current 0.25% ± 1 dgts.
Output contact Rating7 A at 250 volt Relay.
Auxiliary PowerNo External power is required (Draws power from the voltage signal Inputs)
GSM MODEMQuad-Band 850/ 900/ 1800/ 1900 MHz
Environmental1] Working Temp : 0 to 55º C 2] Storage Temp : 10 to 70º C 3] Relative humidity: 0–95 % non-condensive 4] Warm up time : 30 Sec
Enclosure1] Mounting : Surface mounting. 2] Position : Panel. 3] Terminal : Screw ON Terminals.
KEY’SSET: This key is used to change the controller from RUN mode to FUNCTION mode for Parameter setting & to save the modified setting in Function mode INC: Up scroll the parameter & parameter value. DEC: Down scroll the parameter & parameter value.
LED’S1. PUMP ON (GREEN): MOTOR ON. 2 Voltage Fault (RED : SPP, Voltage Unbalance& Reverse Phase Fault. 3. UL (RED) : Under Load 4. OL (RED) : Over Load Fault.
Options
Optional featuresMulti-tone selection site selectable.; Silent push button can be provide to mute sound.; Extra Potential free relay output contact can be provide.; operating Supply voltage can be from 20V DC to 60V DC. Or 90 to 270VAC.

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.