Proton MPC-6 GSM Mobile Pump Controller with Starter
- Brand
- Proton
- Model number
- MPC-6
- Category
- AC & Pump Controllers
Controller for starting and stopping a pump remotely over GSM (Proton MPC-6). Relay output rated 7 A at 250 V.
Price and availability on request
Key features
- 1. Fully programmable
- 2. Suitable for three phase pumps up to 25HP
- 3. Relay outputs for Star-Delta starters
- 4. No auxiliary power supply required for controller operation
- 5. Can be operated in 3 modes such as GSM/AUTO/MANUAL
- 6. GSM based SMS controlled start/stop and remote monitoring
- 7. GSM based Interactive Voice Response System (IVRS) controlled start/stop and remote monitoring for 3 registered numbers
- 8. IVRS – Voice response available in regional language
- 9. Live Motor operation Status available via SMS as Motor ON/OFF status, Live Fault, phase voltages and current drawn per phase
- 10. Inbuilt phone book for auto reply in case of faults
- 11. Complete protection from electrical unhealthy condition
- 12. All parameters are settable through front key
- 13. LED indications for alarm (fault) & MOTOR ON
- 14. Scrolling display of parameters, one by one in scroll mode
- 15. Three bright 7 segment display on unit
- 16. Inverse Time trip curve for over load fault
- 17. It Will give Miss call AT Power ON
- The Motor protection unit continuously scans the faults like Under Voltage, Over Voltage, SPP, Reverse Phase, Voltage Unbalance, Under Load, Over Load, Current unbalance
Specifications
| Input Supply | 3 Phase 415 V, 50 HZ AC (3 Phase 3 wire) |
|---|---|
| Accuracy | 1] Voltage 0.25% ± 1 dgts. 2] Current 0.25% ± 1 dgts. |
| Output contact Rating | 7 A at 250 volt Relay. |
| Auxiliary Power | No External power is required (Draws power from the voltage signal Inputs) |
| GSM MODEM | Quad-Band 850/ 900/ 1800/ 1900 MHz |
| Environmental | 1] Working Temp : 0 to 55º C 2] Storage Temp : 10 to 70º C 3] Relative humidity: 0–95 % non-condensive 4] Warm up time : 30 Sec |
| Enclosure | 1] Mounting : Surface mounting. 2] Position : Panel. 3] Terminal : Screw ON Terminals. |
| KEY’S | SET: This key is used to change the controller from RUN mode to FUNCTION mode for Parameter setting & to save the modified setting in Function mode INC: Up scroll the parameter & parameter value. DEC: Down scroll the parameter & parameter value. |
| LED’S | 1. PUMP ON (GREEN): MOTOR ON. 2 Voltage Fault (RED : SPP, Voltage Unbalance& Reverse Phase Fault. 3. UL (RED) : Under Load 4. OL (RED) : Over Load Fault. |
| Optional features | Multi-tone selection site selectable.; Silent push button can be provide to mute sound.; Extra Potential free relay output contact can be provide.; operating Supply voltage can be from 20V DC to 60V DC. Or 90 to 270VAC. |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.