Proton AC Controller MTNL 2 to 6 AC Controller with Voltage & Current Protection (MTNL)
- Brand
- Proton
- Model number
- AC Controller MTNL
- Category
- AC & Pump Controllers
Controller for automatic duty sharing and changeover of air conditioners (Proton AC Controller MTNL).
Price and availability on request
Key features
- Fully programmable
- Complete protection for A/C from unhealthy condition
- All set points programmable from keypad
- Password protection for controller
- Four key interface for on site programming
- Separate alarm contacts for A/C fail alarm
- Automatic display of A/C parameters one by one in Run Mode
- Status, Healthy & Alarm indication by LED on front panel
- Room temperature sensing by precise sensor
- Direct display of actual current drawn by each compressor
- Direct display of actual room temperature
- Sequencing of comp. for equal run hours, site selectable
- Automatic Timer mode operation if Room sensor fails
- All Faults are Auto resettable
Specifications
| Indications | 1] Supply ON for A/C1 & A/C2, A/C3, A/C4, A/C5, A/C6. Colour: Green 2] Underload / Overload Fault: Colour: Red 3] Sensor Fail fault Colour: Red 4] Room High fault Colour: Red 5] Fire alarm Colour: Red 6] Healthy Colour: Green 7] Keys: 4 key keypad for settings. 1] SET Key: To enter into FUNCTION SET Mode/To view the next set pt. 2] Up Arrow Key: To increment the set point 3] Down Arrow Key: To decrement the set point. 4] ENTER Key: To come out of FUNCTION SET mode/To enter into menu/To accept th |
|---|---|
| Mounting | Wall mounting |
| Sensing | 1. Inbuilt current sensing for compressor. 2. Temperature Sensing by precise Temp. Sensor. 3. Fire Alarm sensing. |
| Terminals | 1. Separate O/P s for each Compressor. 2. Temperature sensor. 3. Alarm relay o/p. |
| Alarms/ Protections | 1. Over load protection set point user settable. 2. Under load protection set point user settable. 3. High/low temperature alarm set point user settable. |
| RUN MODE PARAMETERS | 1. Room Temperature 2. CP1, CP2 CP3 CP4 CP5 CP6 Amp. 3. Fault message if any |
| FAULTS/PROTECTION | 1. Primary Fault related to protections of, A/C1, A/C2, A/C3, A/C4, A/C5, A/C6 Under load (UL) & Room Low. 2. Secondary Fault related to protections of, A/C1, A/C2, A/C3, A/C4, A/C5, A/C6:- Overload (OL). 3. Room Temperature High 4. Room sensor fail / Room High protection. 5. Fire Alarm Protection. 6. MCB is used for Short circuit protection. |
| Optional features | Multi-tone selection site selectable.; Silent push button can be provide to mute sound.; Extra Potential free relay output contact can be provide.; operating Supply voltage can be from 20V DC to 60V DC. Or 90 to 270VAC. |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.