Proton AHU Controller AHU Controller

Brand
Proton
Model number
AHU Controller

Controller for air handling units that runs and protects up to 3 compressors and the blower.

Price and availability on request

Request a quote

Sent with the product details: Proton AHU Controller AHU Controller.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Controls up to 3 Compressors and a Blower
  • Protects the compressor with the advanced Proton Motor Protection Unit (MPU) from unhealthy conditions like Under Load, Over Load,
  • Under Voltage, Over Voltage, Single Phasing, Voltage Unbalance, and Current Unbalance
  • Main Controller with 16 X 2 LCD Display protects the 3 phase blower from unhealthy voltage and current conditions
  • Main controller communicates with MPU via RS 485 Modbus and displays the data sensed by the MPU
  • Accurate sensing temperature by precise temperature sensors
  • Time sharing for compressors to share load equally
  • Continuous display of Room Temperature, Voltage and Current drawn by compressors, and Faults if any
  • Data logging of faults occurred in on Main Controller
  • Sequencing of comp. for equal run hours, site selectable
  • Automatic Timer mode operation if Room sensor fails

Specifications

Specifications
Measured Parameters-: 1] Voltage (Volt) Phase – Phase measured. (RMS) 2] Unbalance Voltage measured Phase – Phase Unbalance measured. 3] Current (Amps) Compressor1, Compressor2, Heater, Blower (3Ph 4 w). 4] Room Temperature.
Protection-: 1] Over Voltage Protection (Settable) 2] Under Voltage Protection (Settable). 3] Over Load Protection (Settable). 4] Under Load Protection (Settable). 5] Unbalance (Settable) 6] Reverse Phasing (Settable) 7] Phase Failure Protection (Settable) 8] High pressure (potential free input) (AC1/AC2) 9] Low pressure (potential free input) (AC1/AC2) 10] AHU Door Open (potential free input) (Blower/Master controller)
Auxiliary Power-: No External power is required (Draws power from the voltage signal Inputs)
Accuracy-: 1] Volt 0.25% rdg ± 1 dgts. 2] Current 0.25% rdg ± 1 dgts.
Communication Output-: 1] Serial port : RS 485 2] Baud rate : Default: 9600 3] Start bit : 1 4] Stop bit : 1 5] Protocol : MODBUS - RTU
Environmental-: 1] Working Temp : 0 to 55° C 2] Storage Temp : 10 to 70° C 3] Relative humidity : 0 – 95 % non-condensive
Options
Optional featuresMulti-tone selection site selectable.; Silent push button can be provide to mute sound.; Extra Potential free relay output contact can be provide.; operating Supply voltage can be from 20V DC to 60V DC. Or 90 to 270VAC.

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.