Multispan MPD-192 Multifunction 3 Phase Protection Relay, Panel Mount
- Brand
- Multispan
- Model number
- MPD-192
- Category
- Motor Protection Relays
Panel-mount three-phase protection relay and VAF monitor with 3-line display, programmable voltage, current, frequency, unbalance and locked-rotor trips, two relays and optional RS-485 Modbus.
Price and availability on request
Key features
- 3 Line – 3 Digit Display for Easy to Use and Understand 3 Phase Value
- 3 Phase 3 Wire / 4 Wire Selectable
- Display 3 Phase Voltage (Ph-Ph, Ph-N), 3 Phase Ampere & Frequency
- Programmable Tripping Parameter
- Single Instrument works for Both VAF Monitoring and Protection Relay
- Programmable Relay 1 Relay 2 C/O
- Fail Safe and Non Fail Safe Mode
- RS-485 MODBUS Available as on request
Specifications
| Direct Voltage AC | 30 to 300V(L - N); 50 to 520V(L - L) |
|---|---|
| Burden | < 0.2VA |
| Primary CT Ratio | 5 to 6000 Amp selectable |
|---|---|
| Secondary Current AC | 0.1 to 5 Amp |
| Overload | Up to 6A continuous |
| Frequency | 45.0 to 65.0 Hz |
| Display | 3 Digit, 3 Line 7 Seg 0.56”, RED LED |
|---|---|
| Keys | Scroll, SET, RST, INC, DEC |
| Size (mm) | 96 (H) X 96 (W) X 54 (D) mm |
|---|---|
| Panel Cutout (mm) | 92 (H) X 92 (W) mm |
| Network Selection | 3 Phase - 4 Wire,3 Phase - 3 Wire |
| Under Current | 0.00 to CTR |
|---|---|
| Over Current | 0.00 to CTR |
| Under Voltage | 50 to 520V For 3Ø - 3W; 30 to 300V For 3Ø - 4W |
| Over Voltage | 50 to 550V For 3Ø - 3W; 30 to 330V For 3Ø - 4W |
| Over / Under Frequency | 45.0 to 65.0 Hz |
| Short Circuit | 1 - 9 Scale |
| Lock Rotor Point | 0.5 to 9.0 Scale |
| Unbalance | 5 - 60% |
| Power On Delay | 0 to 99 Sec |
|---|---|
| Initial Time Delay | 0 to 99 Sec |
| Trip Delay Time(Voltage, Current, Frequency, SSP, Unbalance) | 0 to 999 Sec |
| Scrolling Time | 1 to 99 Sec |
| Reset Time | 0 to 99 Sec |
| Relay | 2 Nos |
|---|---|
| Relay Type | 1st Relay ( NO - C - NC ); 2nd Relay ( NO - C ) |
| Rating | 1st Relay 10Amp, 230V AC (Resistive Load); 2nd Relay 5 Amp (With Simultaneous Actuation) |
| Supply Voltage | 100 to 270V AC/DC, 50/60Hz |
|---|---|
| Power Consumption | 3VA @ 230 AC MAX |
| Working Temperature | 0 to 55°C |
|---|---|
| Storage Temperature | 0 to 55°C |
| Relative Humidity | 95 % RH Non-Condensing |
| Protection Level (As Per request) | IP-65 (Front side As per IS/IEC 60529 : 2001) |
| Typical uses | Electrical Control Panel, Submersible Pump, Road Construction Panel, MCC Panel, Industrial Chiller And HV AC System, D.G. Set |
|---|
| MPD-192-E3-N0 | Voltage Input 30 to 300V AC (L-N), 50 to 520V AC (L-L); Ampere Input 60mA to 5A AC CT Selectable, CT Selectable up to 6000/5; Supply 100-270V AC/DC |
|---|---|
| MPD-192-E2-N0 | Voltage Input 30 to 300V AC (L-N), 50 to 520V AC (L-L); Ampere Input 60mA to 5A AC CT Selectable, CT Selectable up to 6000/5; Supply 50-550V AC |
| MPD-192-E3-N7 | Voltage Input 30 to 300V AC (L-N), 50 to 520V AC (L-L); Ampere Input Fixed Multispan 30A- 3 Ph CT Module; Supply 100-270V AC/DC |
| MPD-192-E3-N6 | Voltage Input 30 to 300V AC (L-N), 50 to 520V AC (L-L); Ampere Input Fixed Multispan 60A- 3 Ph CT Module; Supply 100-270V AC/DC |
| MPD-192-E3-N8 | Voltage Input 30 to 300V AC (L-N), 50 to 520V AC (L-L); Ampere Input Fixed Multispan 125A- 3 Ph CT Module; Supply 100-270V AC/DC |
| MPD-192-M1-E3-N0 | Voltage Input 30 to 300V AC (L-N), 50 to 520V AC (L-L); Ampere Input 60mA to 5A AC CT Selectable, CT Selectable up to 6000/5; Supply 100-270V AC/DC |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.