Multispan MPD-152 Multifunction 3 Phase Protection Relay, DIN Rail
- Brand
- Multispan
- Model number
- MPD-152
- Category
- Motor Protection Relays
DIN-rail three-phase protection relay and VAF monitor with 3-line display of phase voltages, currents and frequency, programmable trip parameters and one relay with two changeover contacts.
Price and availability on request
Key features
- 3 Line – 3 Digit Display for Easy to Use and Understand 3 Phase Value
- 3 Phase 3 Wire / 4 Wire Selectable
- Display 3 Phase Voltage (Ph-Ph, Ph-N), 3 Phase Ampere & Frequency
- Programmable Tripping Parameter
- Single Instrument works for Both VAF Monitoring and Protection Relay
- Programmable Relay 1 Relay 2 C/O
- Fail Safe and Non Fail Safe Mode
- Size: 75 X 55 X 110 (H XW X D) mm
- Supply Voltage : 100-270V AC
Specifications
| Direct Voltage AC | 30 to 300V(L - N); 50 to 520V(L - L) |
|---|---|
| Burden | < 0.2VA |
| Primary CT Ratio | 5 to 6000 Amp selectable |
|---|---|
| Secondary Current AC | 0.5 to 5 Amp |
| Overload | Up to 6A continuous |
| Frequency | 45.0 to 65.0 Hz |
| Display | 3 Digit, 3 Line 7 Seg 0.28”, RED LED |
|---|---|
| Keys | SET, INC, DEC, RST |
| Size (mm) | 75(H)X 55(W)X110(D) |
|---|---|
| NETWORK SELECTION | 3 Phase - 4 Wire,3 Phase - 3 Wire, |
| ACCURACY | Class 0.5 (Standard) |
| Under Current | 0.00 to CTR |
|---|---|
| Over Current | 0.00 to CTR |
| Under Voltage | 50 to 520V For 3Ø - 3W; 30 to 300V For 3Ø - 4W |
| Over Voltage | 50 to 550V For 3Ø - 3W; 30 to 330V For 3Ø - 4W |
| Over / Under Frequency | 45.0 to 65.0 Hz |
| Short Circuit | 1 - 9 Scale |
| Lock Rotor Point | 0.5 to 9.0 Scale |
| Unbalance | 5 - 60% |
| Power On Delay | 0 to 99 Sec |
|---|---|
| Initial Time Delay | 0 to 99 Sec |
| Trip Delay Time(Voltage, Current, Frequency, SSP, Unbalance) | 0 to 999 Sec |
| Scrolling Time | 1 to 99 Sec |
| Reset Time | 0 to 99 Sec |
| Relay | 1 Nos |
|---|---|
| Relay Type | 1 C/O (NO-C-NC) |
| Rating | 10Amp, 250V AC |
| Supply Voltage | 100 to 270V AC, 50Hz |
|---|---|
| Power Consumption | 3VA @ 230 AC MAX |
| Working Temperature | 0 to 55°C |
|---|---|
| Storage Temperature | 0 to 55°C |
| Relative Humidity | 95 % RH Non-Condensing |
| Typical uses | Electrical Control Panel, Submersible Pump, Road Construction Panel, MCC Panel, Industrial Chiller And HV AC System, D.G. Set |
|---|
| MPD-152-A2-00 | Voltage Input 30 to 300V AC (L-N), 50 to 520V AC (L-L); Ampere Input CT Selectable up to 6000/5A AC; Output 1R 1 C/O; Supply 100 to 270V AC |
|---|---|
| MPD-152-A2-07 | Voltage Input 30 to 300V AC (L-N), 50 to 520V AC (L-L); Ampere Input Fixed Multispan 30A- 3 Ph CT Module; Output 1R 1 C/O; Supply 100 to 270V AC |
| MPD-152-A2-06 | Voltage Input 30 to 300V AC (L-N), 50 to 520V AC (L-L); Ampere Input Fixed Multispan 60A- 3 Ph CT Module; Output 1R 1 C/O; Supply 100 to 270V AC |
| MPD-152-A2-08 | Voltage Input 30 to 300V AC (L-N), 50 to 520V AC (L-L); Ampere Input Fixed Multispan 125A- 3 Ph CT Module; Output 1R 1 C/O; Supply 100 to 270V AC |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.