Motwane M65 Dual Display TRMS Digital Multimeter

Brand
Motwane
Model number
M65

Dual-display true RMS multimeter for R&D and process work, CAT III 1000 V and IP54: 0.25% basic DCV accuracy, µA to 10 A current, capacitance to 60 mF, frequency to 60 MHz and a 60-segment bar graph.

Price and availability on request

Request a quote

Sent with the product details: Motwane M65 Dual Display TRMS Digital Multimeter.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • 6,000 count LCD dual display with white backlight
  • Auto ranging, TRMS AC voltage & current measurement
  • Basic DCV accuracy of 0.25%
  • Highly linear readings
  • Capacitance range up to 60mF
  • Resistance, diode and continuity measurement facility
  • Selectable frequency & duty cycle measurement
  • 60 position analog bar graph for trend indication
  • Select, Range, Hold, Rel, Light and Max/Min functions
  • CE and IEC 61010-1 CAT III (1000V), IP 54 protection
  • Robust, rugged and double mould casing

Specifications

DC voltage
Ranges / accuracy6V, 60V, 600V ±⁠(0.25% + 3); 1000V ±⁠(0.5% + 3); input impedance 10MΩ approx.
AC voltage (TRMS, 50-500Hz)
Ranges / accuracy6V, 60V, 600V ±⁠(1% + 5); 1000V ±⁠(1.2% + 8)
DC current
Ranges / accuracy600µA / 6000µA ±⁠(1.2% + 5); 60mA / 600 mA ±⁠(1.5% + 5); 10 A ±⁠(1.5% + 8)
AC current (TRMS, 50-500Hz)
Ranges / accuracy600µA / 6000µA ±⁠(1.5% + 5); 60mA / 600 mA ±⁠(1.8% + 5); 10 A ±⁠(2.0% + 8)
Resistance
Ranges / accuracy600 Ω to 600 KΩ ±⁠(0.5% + 3); 6 MΩ ±⁠(1% + 5); 60 MΩ ±⁠(3% + 10)
Capacitance
Ranges / accuracy6 nF ±⁠(5.0% + 10); 60 nF to 60 µF ±⁠(3.0% + 10); 600 µF ±⁠(5.0% + 10); 6 mF ±⁠(5.0% + 20); 60 mF ±⁠(5.0% + 30)
Frequency
Ranges / accuracy60 Hz to 60 MHz, ±⁠(0.5% + 3)
Diode test
Range6V; open circuit voltage <3.0 V DC, test current <2.0mA approx.
Continuity
Range600.0Ω, meter beeps < 60Ω
General
Display6,000 count dual LCD with white backlight, 60 position bar graph
Dual displayAC voltage with frequency, frequency with duty cycle
Display update rate2.8 times per second nominal
Measurement categoryCAT III (1000V), reinforced insulation
FusesµA & mA input 0.8 A / 250V fast blow ceramic; 10A input 20A / 500V fast blow ceramic
Power consumption8mA typical
Operating temperature0°C to 50°C
Relative humidity80% RH @ 5°C to 31°C; 50% RH @ 31°C to 40°C, non condensing
Storage temperature-20°C to 60°C
Power supply9V battery type 6F22 or equivalent
Low battery indication'LO BAT' displayed below 6.5V approx.
Auto power offAfter 15 min
CE directivesLVD 2006/95/EC, EMC 2004/104/EC
StandardsEN 61010-1:2010, EN61326-1:2006
IP ratingIP 54
Dimensions94 x 205 x 36 mm approx.
Weight450g approx.
Ordering
Optional accessoriesPair of test leads; pair of small test leads
Supplied with
Standard accessoriesPair of test leads; user manual; battery installed; fuses; carrying bag

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.