Mean Well NSP-3200-24 Enclosed Switching Power Supply 24 V, 133 A, 3192 W

Model number
NSP-3200-24

Mean Well NSP-3200-24, an enclosed switching power supply from the NSP-3200 series for 90-264 V AC input, up to 93.5% efficient, for machines, control panels and LED systems.

Price and availability on request

Request a quote

Sent with the product details: Mean Well NSP-3200-24 Enclosed Switching Power Supply 24 V, 133 A, 3192 W.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • 90~264Vac input with PFC
  • Output voltage 50~125% programmable
  • Built-in CANBus protocol
  • 20~+70℃ wide range operation temperature
  • Built-in constant current limiting circuit
  • High efficiency up to 94.5%
  • Built-in remote ON-OFF control / Remote Sense / 12Vaux power / DC OK signal / OTP alarm signal
  • Built-in intelligent fan speed control
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Design refer to SEMl F47 at 200Vac
  • 5 years warranty

Specifications

Output
DC voltage24V
Rated current133A
Current range0 ~ 133A
Rated power3192W
Ripple & noise (max.)300mVp-p
Voltage adj. range23.5 ~ 30V
Voltage tolerance±1.0%
Line regulation±0.5%
Load regulation±0.5%
Setup, rise time1500ms, 60ms/230Vac at full load
Hold up time (typ.)16ms / 230Vac at 70% load 8ms / 230Vac at full load
Input
Voltage range90 ~ 264Vac 127 ~ 400Vdc
Frequency range47 ~ 63Hz
Power factor (typ.)0.97/230Vac at full load
Efficiency (typ.)93.5%
AC current (typ.)17A/230Vac
Inrush current (typ.)COLD START 55A/230Vac
Leakage current<2mA / 230Vac
Protection
Overload105 ~ 115% rated output power; Protection type : Constant current limiting, shut down O/P voltage 5 sec. after O/P voltage is down low, re-power on to recover
Over voltage31.5 ~ 37.5V; Protection type : Shut down o/p voltage, re-power on to recover
Over temperatureShut down o/p voltage, recovers automatically after temperature goes down
Function
Voltage programmable(PV)Adjustment of output voltage is allowable to 50 ~ 125% of nominal output voltage; Please refer to the Function Manual in following pages
Remote controlBy electrical signal or dry contact Power ON:short Power OFF:open. Please refer to the Function Manual in following pages
Remote senseCompensate voltage drop on the load wiring up to 0.5Vdc. Please refer to the Function Manual in following pages
Auxiliary power12Vaux @ 0.8A, tolerance ±10%
Alarm signalIsolated TTL signal output for T-Alarm and DC-OK. Please refer to the Function Manual in following pages
Environment
Working temp.-20 ~ +70℃ (Refer to "Derating Curve")
Working humidity20 ~ 90% RH non-condensing
Storage temp., humidity-40 ~ +85℃, 10 ~ 95% RH non-condensing
Temp. coefficient±0.03%/℃ (0 ~ 50℃)
Vibration10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
Safety & EMC
Safety standardsUL62368-1, CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, BIS IS 13252(Part 1):2010/ IEC 60950-1 : 2005,; EAC TP TC 004 approved
Withstand voltageI/P-O/P:3KVac I/P-FG:2KVac O/P-FG:1.5KVac
Others
MTBF637.4K hrs min. Telcordia SR-332 (Bellcore) ; 63.7K hrs min. MIL-HDBK-217F (25℃)
Dimension325.8*107*41mm (L*W*H)
Packing2.24Kg;4pcs/10Kg/1.09CUFT

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.