Mean Well NSP-3200-24 Enclosed Switching Power Supply 24 V, 133 A, 3192 W
- Brand
- Mean Well
- Model number
- NSP-3200-24
- Category
- Industrial Power Supplies
Mean Well NSP-3200-24, an enclosed switching power supply from the NSP-3200 series for 90-264 V AC input, up to 93.5% efficient, for machines, control panels and LED systems.
Price and availability on request
Key features
- 90~264Vac input with PFC
- Output voltage 50~125% programmable
- Built-in CANBus protocol
- 20~+70℃ wide range operation temperature
- Built-in constant current limiting circuit
- High efficiency up to 94.5%
- Built-in remote ON-OFF control / Remote Sense / 12Vaux power / DC OK signal / OTP alarm signal
- Built-in intelligent fan speed control
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Design refer to SEMl F47 at 200Vac
- 5 years warranty
Specifications
| DC voltage | 24V |
|---|---|
| Rated current | 133A |
| Current range | 0 ~ 133A |
| Rated power | 3192W |
| Ripple & noise (max.) | 300mVp-p |
| Voltage adj. range | 23.5 ~ 30V |
| Voltage tolerance | ±1.0% |
| Line regulation | ±0.5% |
| Load regulation | ±0.5% |
| Setup, rise time | 1500ms, 60ms/230Vac at full load |
| Hold up time (typ.) | 16ms / 230Vac at 70% load 8ms / 230Vac at full load |
| Voltage range | 90 ~ 264Vac 127 ~ 400Vdc |
|---|---|
| Frequency range | 47 ~ 63Hz |
| Power factor (typ.) | 0.97/230Vac at full load |
| Efficiency (typ.) | 93.5% |
| AC current (typ.) | 17A/230Vac |
| Inrush current (typ.) | COLD START 55A/230Vac |
| Leakage current | <2mA / 230Vac |
| Overload | 105 ~ 115% rated output power; Protection type : Constant current limiting, shut down O/P voltage 5 sec. after O/P voltage is down low, re-power on to recover |
|---|---|
| Over voltage | 31.5 ~ 37.5V; Protection type : Shut down o/p voltage, re-power on to recover |
| Over temperature | Shut down o/p voltage, recovers automatically after temperature goes down |
| Voltage programmable(PV) | Adjustment of output voltage is allowable to 50 ~ 125% of nominal output voltage; Please refer to the Function Manual in following pages |
|---|---|
| Remote control | By electrical signal or dry contact Power ON:short Power OFF:open. Please refer to the Function Manual in following pages |
| Remote sense | Compensate voltage drop on the load wiring up to 0.5Vdc. Please refer to the Function Manual in following pages |
| Auxiliary power | 12Vaux @ 0.8A, tolerance ±10% |
| Alarm signal | Isolated TTL signal output for T-Alarm and DC-OK. Please refer to the Function Manual in following pages |
| Working temp. | -20 ~ +70℃ (Refer to "Derating Curve") |
|---|---|
| Working humidity | 20 ~ 90% RH non-condensing |
| Storage temp., humidity | -40 ~ +85℃, 10 ~ 95% RH non-condensing |
| Temp. coefficient | ±0.03%/℃ (0 ~ 50℃) |
| Vibration | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| Safety standards | UL62368-1, CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, BIS IS 13252(Part 1):2010/ IEC 60950-1 : 2005,; EAC TP TC 004 approved |
|---|---|
| Withstand voltage | I/P-O/P:3KVac I/P-FG:2KVac O/P-FG:1.5KVac |
| MTBF | 637.4K hrs min. Telcordia SR-332 (Bellcore) ; 63.7K hrs min. MIL-HDBK-217F (25℃) |
|---|---|
| Dimension | 325.8*107*41mm (L*W*H) |
| Packing | 2.24Kg;4pcs/10Kg/1.09CUFT |