Mean Well NSP-1600-12 Enclosed Switching Power Supply 12 V, 125 A, 1500 W

Model number
NSP-1600-12

Mean Well NSP-1600-12, an enclosed switching power supply from the NSP-1600 series for 90-264 V AC input, up to 89% efficient, for machines, control panels and LED systems.

Price and availability on request

Request a quote

Sent with the product details: Mean Well NSP-1600-12 Enclosed Switching Power Supply 12 V, 125 A, 1500 W.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • 90~264Vac input with PFC
  • Output voltage 40~125% programmable (15~125% by request)
  • Built-in CANBus protocol
  • 20~+70℃ wide range operation temperature
  • Built-in constant current limiting circuit
  • High efficiency up to 92.5%
  • Built-in remote ON-OFF control / Remote Sense / 12Vaux power / DC OK signal / OTP alarm signal
  • Built-in intelligent fan speed control
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Design refer to SEMl F47 at 200Vac
  • 5 years warranty

Specifications

Output
DC voltage12V
Rated current125A
Current range0 ~ 125A
Rated power1500W
Ripple & noise (max.)150mVp-p
Voltage adj. range11.5 ~ 15V
Voltage tolerance±1.0%
Line regulation±0.5%
Load regulation±0.5%
Setup, rise time1500ms, 60ms/230Vac at full load
Hold up time (typ.)16ms / 230Vac at 70% load 10ms / 230Vac at full load
Input
Voltage range90 ~ 264Vac 250 ~ 400Vdc
Frequency range47 ~ 63Hz
Power factor (typ.)0.97/230Vac at full load
Efficiency (typ.)89%
AC current (typ.)14A/115Vac 8A/230Vac 15A/115Vac 8.5A/230Vac
Inrush current (typ.)COLD START 35A/230Vac
Leakage current<2mA / 230Vac
Protection
Overload105 ~ 115% rated output power; Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. After O/P voltage falls, re-power on to recover
Over voltage15.75 ~ 18.75V; Protection type : Shut down o/p voltage, re-power on to recover
Over temperatureShut down o/p voltage, recovers automatically after temperature goes down
Function
Voltage programmable(PV)Adjustment of output voltage is allowable to 40 ~ 125%(12V: 60~125%) of nominal output voltage ; 15~125% by request.; Please refer to the Function Manual.
Remote controlBy electrical signal or dry contact Power ON:short Power OFF:open. Please refer to the Function Manual
Remote senseCompensate voltage drop on the load wiring up to 0.5Vdc. Please refer to the Function Manual
Auxiliary power12Vaux @ 0.8A
Alarm signalIsolated signal output for T-alarm and DC OK
Environment
Working temp.-20 ~ +70℃ (Refer to "Derating Curve")
Working humidity20 ~ 90% RH non-condensing
Storage temp., humidity-40 ~ +85℃, 10 ~ 95% RH non-condensing
Temp. coefficient±0.03%/℃ (0 ~ 50℃)
Vibration10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
Safety & EMC
Safety standardsUL62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, BSMI CNS15598-1,; BIS IS 13252(Part 1):2010/ IEC 60950-1 : 2005 (except for 48V), AS/NZS62368.1, EAC TP TC 004 approved
Withstand voltageI/P-O/P:3KVac I/P-FG:2KVac O/P-FG:1.5KVac
Others
MTBF684.7K hrs min. Telcordia SR-332 (Bellcore) ; 69.2K hrs min. MIL-HDBK-217F (25℃)
Dimension300*85*41mm (L*W*H)
Packing1.8Kg;6pcs/11.3Kg/1.25CUFT

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.