Masibus TT7S10E-XP Flame Proof Temperature Transmitter
- Brand
- Masibus
- Model number
- TT7S10E-XP
- Category
- Sensors and Transmitters
Masibus TT7S10E-XP flame proof temperature transmitter: output ± 0.04% of Full Span. For power plants, metal industry.
Price and availability on request
Key features
- Universal input
- RTD (3W / 4W)
- Thermocouple
- Resistance
- User friendly configuration and calibration using
- Touch keys
- Windows based mTran software
- HART COMMUNICATOR
- Easy to read - 0.4″, 4-digit LED display for efficient monitoring
- HART 7 functionality with HART 5 compatibility
- 1.5 KV RMS Isolation between Input & Output
- Linearized Output
- PV bias for input correction
- Digital Filter
- Built in Reverse polarity protection
Specifications
| RTD | PT100 3/4-Wire ; Pt100 3/4 wire / -200 to 850.0°C |
|---|---|
| Resistance/Potentiometer | 0-2500Ω |
| Thermocouple | E, J, K, T, B, R, S, N with internal CJC (ANSI standard) |
| Linear | 0 to 75mv/500mVDC, 0/4 - 20 mA |
| RTD/Resistance/Potentiometer Excitation Current | ~0.2 mA |
| Input Impedance for mV Input | ≥ 1M Ω |
| Input Impedance for mA Input | ≤ 10 Ω |
| Sensor Burnout Current | < 1 uA |
| Input Range | Refer Table -1 |
| Zero / Span Adjust | Adjustable either from TouchKeys, mTRAN Software or HART Modem |
| Accuracy (A/D) | ±0.6 °C for E, J, K, T, N. ±0.5 °C PT100. ±1.5 °C for B, R, S. ±0.020 mV for Linear (0 - 75mV). ±0.400 mV for Linear (0 - 500mV). ±1.5 Ω for Resistance (0 - 2500 Ω). ±0.008 mA for mA (0 - 20 & 4 - 20 mA). |
| CJC Error | ±2 °C |
| ADC Resolution | 17 bits |
| Stability | ±0.1% per year |
| Response Time | ≤ 250ms |
| Digital Filter | 0-20 User programmable |
| Allowable Wiring Resistance for RTD | Maximum 15 ohms/wire (Resistance between all wires should be equal) |
| CMRR | >120 dB |
| NMRR | ~40 dB |
| Temp-co | <100 PPM Table-1: Display Range |
| Linear V | 0 to 75mV / 0 to 500mV DC -1999 to 99; 0 to 500mV DC |
| Linear mA | 0 to 20mA / / -1999 to 99; 4 to 20mA |
| Resistance/ Potentiometer | 0-2500Ω; -1999 to 99 |
| Display Type | 0.4", 4 Digit 7 Segment Red LED |
|---|---|
| Touch Keys | 3 Touch keys (ENT, ESC, INC) for configuration, calibration and Operation |
| mA Output (2 wire) | 4-20mA or 20-4mA (User programmable) |
|---|---|
| Output Accuracy (D/A) | ± 0.04% of Full Span |
| Sensor Break Output | ≤ 3.6 or ≥21.0mA programmable. |
| Output Load | R load = (V supply - 12.5)/0.021 Ohm |
| Total Accuracy | (A/D Accuracy / Span + D/A Accuracy). Example: when selecting Pt100 with measurement range of 0 to 800 °C 0.5°C/800°C ×100% of span +0.04% of span = 0.1% of span |
| Standard | 12.5 - 36 VDC |
|---|
| Standard Operating Temperature | 0 to 80°C |
|---|---|
| Storage Temperature | -20 to 85 °C |
| Humidity | 30% to 95% RH(Non-condensing) |
| Mounting | Wall (Std) or 2" Pipe mount (optional) |
|---|---|
| Dimensions in mm | 140(H) x 145(W) x 80(D) / 100(H) x 100(W) x 145(D) |
| Weight (Without mounting clamps) | 1 Kg / 1.65 Kg |
| Enclosure Material | Aluminium / Alloy LM-6 |
| Ingress Protection | IP65 / IP66 |
| Area Classification | Zone 1 & 2, Gas / Group: IIA & IIB |
| Cable Entry Size | 2 nos. of M20 double co / mpression cable glands |
| HART Physical Layer | FSK 1200 |
|---|---|
| Baud Rate | 1200bps |
| NAMUR Compliance | Output limit and failure current acc. To NAMUR NE 43 |
| Available Command | Device information, Range, Unit, Damping value, Polling address, Output trimming, Tag, Message, Descriptor, Date. |
| Identified Commands | Generic mode: 0, 1, 3, 6, 12, 13,14, 17, 18, 34, 35, 40, 42, 44, 45, 46. |
| Applications | Power Plants, Metal Industry, Oil & Gas, Chemical, Glass Industry, Cement, Fertilizer, Paper/Pulp |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.