Masibus TT7S10-XP Loop Powered Temperature Transmitter

Brand
Masibus
Model number
TT7S10-XP

Masibus TT7S10-XP loop powered temperature transmitter: output ±0.25% of FS, 13.5-36 V DC, 2 Wire supply. For industrial process control, factory automation.

Price and availability on request

Request a quote

Sent with the product details: Masibus TT7S10-XP Loop Powered Temperature Transmitter.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Universal input (RTD, Thermocouple, Ohm, mV)
  • Available in wall or 2″ Pipe mount Ex-proof Transmitter with touch sense keys0.56″, 4 digit LED display in Single Compartment0.39″, 4 digit LED display in Dual Compartment
  • 1.5 KV RMS Isolation between Input & Output
  • Linearized Output
  • Highly Accurate
  • Fully Programmable for Input type & Range
  • Digital Filter
  • Easy configuration using keys and display
  • Windows mTRAN software for Configuration, Calibration & Monitoring
  • Reverse Loop polarity protection
  • Direct / Reverse output
  • Sensor break detection

Specifications

Input Type
RTDPt100, 3/4-Wire
Resistance/Potentiometer0-2500Ω
Sensor Current0.2 mA
ThermocoupleE,J,K,T,B,R,S,N with Internal CJC (ANSI Standard)
Linear0-75 mV/0-500 mV DC/ 4-20mA/0-20mA
Input Impedance for V Input> 1MΩ
Input Burden for mA Input≤ 1V
Sensor Break current< 1 uA
Input RangeRefer Table -1
Zero / Span AdjustAdjustable either from Keyboard or from mTRAN Software
Accuracy
E,J,K,T,N,Pt1000.1% of FS, ±1 °C
B,R,S0.25% of FS, ±1 °C
Linear, Potentiometer0.1% of FS, ±1 Unit
CJC Error
E,J,K,T,N±2 °C
B,R,S±3 °C
ADC Resolution16 bits
Stability± 0.1% per year
Response time< 1 sec approx., if filter is set to 0
Digital Filter0-20 settable through software (2 default)
Sensor open DetectionAvailable (Except 0-20mA I/P)
Allowable wiring resistance for RTDMaximum 15 ohms/wire (Resistance between all wires should be equal)
CMRR>120 dB
NMRR~40 dB
Temp-co<150 ppm
Display & Keys
Display size0.56" / 0.39"
Display type7 segment, Red LED, 4 digits
Keys3 keys (ENT, ESC, INC) for configuration, calibration and operation
Output
Current Output (2 wire)4-20mA or 20-4mA (User programmable, Scaled by OPLO and OPHI)
Output accuracy±0.25% of FS
Sensor break Output<3.8 or >20.8mA programmable
Output loadR load = (V supply-13.5)/0.021Ω
Communication
InterfaceTTL (3wire), Protocol-Modbus RTU
Baud Rate9600 bps
Power Supply
Power Supply13.5-36 V DC, 2 Wire
Isolation
Galvanic Isolation1500V AC for 1 minute between input & output
Physical
MountingWall (Std) or 2" Pipe mount (optional)
Dimensions in mm140(H) x 145(W) x 80(D) / 100(H) x 100(W) x 145(D)
Weight (without mounting clamps)1 Kg / 1.65 Kg
Enclosure MaterialAluminum Alloy LM-6
Ingress ProtectionIP65 / IP66
Area ClassificationZone 1 & 2, Gas Group: IIA & IIB
Cable entry size2 nos of M20 double compression cable glands
Environmental
Storage temperature-20 to 85°C Humidity 30% to 95% RH(Non-condensing) Table-1: Display Range
RTDPt100 3/4 wire / -200 to 850.0°C
Linear0-75mV DC 0-500mV DC -1999 to 99 4-20 mA 0-20 mA; 0-20 mA
Resistance/ Potentiometer0-2500Ω; -1999 to 99
Product
ApplicationsIndustrial process control, Factory automation, Interface SCADA, Heat treatment furnaces, Reheat furnaces, Ceramic Kilns, Glass Industry, Water and waste water control
IndustriesPower Plants, Metal Industry, Oil & Gas, Chemical, Glass Industry, Cement, Fertilizer, Paper, Pulp

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.