Masibus MSC Smart Protocol Converter / Gateway
- Brand
- Masibus
- Model number
- MSC
- Category
- Automation Accessories
Masibus MSC smart protocol converter / gateway. For operator interfaces, solar string / environmental monitoring.
Price and availability on request
Key features
- Supports max. upto 247 Modbus RTU slave IDs
- No. of RS-485 ports (Modbus RTU master): 1 No
- Modbus TCP/IP (ModNet) - 10/100Mbps- Auto detecting
- No. of client supports on Modbus TCP/IP (ModNet) - Up to 15 No
- Not required any Modbus query Mapping/Configuration
- RS-485 half duplex communication
- Auto baud rate detection
- Signal boost up to 1200m (Depends upon baud rate)
- Maximum 31 RS-485 nodes per repeater
- 120 termination resistor selection
- Isolation 1500VAC RMS
- Integrates multiple Modbus RTU slaves into Single Profibus Network
- Fast cyclic data communication between Master and Slave
- Supports up to 100 commands or 512 Read & Write Registers on MODBUS
- Diagnostic and configuration via RS232
Specifications
| Communication controller Type | ARM 926EJ-S / 200 MHz / MMU |
|---|---|
| Configuration Port | RS-232 for diagnostic and configuration |
| Master Communication | RS-485 (Optically isolated) Modbus RTU |
| Configuration Software | mPC Tool (Supports windows OS) |
| Communication Controller Type | ARM cortex M4 32-bit MCU |
| Communication Protocol Support | Modbus TCP server/slave, Modbus RTU master |
| Indication LEDs | Power, status, RS-485 communication rx/tx |
| Ethernet Indication LED | link, activity LED |
| I/O | Maximum of 244 bytes cyclic input and 244 bytes output data |
|---|---|
| Transmission Rate | 9.6 to 12 Mbps |
| Connector | D-Sub female connector, 9 PIN |
| Functions | DP V0 (Cyclic communication) |
| Data Transport Layer | DP V0 (Cyclic communication) |
| I/O | Max. No. of I/O data 512 read/512 write registers or 100 commands |
|---|---|
| Function Codes | 01 - Read coil status 02 - Read input status 03 - Read holding register 04 - Read input register 05 - Force single coil 06 - Preset single register 15 - Force multiple coils 16 - Preset multiple register |
| Serial Communication Parameters | Data bits - 8 bits Stop bits - 1, 2 Parity bits - None, even, odd |
| Maximum Units | 31 unit per host (Node number: 1 to 126) |
| Network Interface | Ethernet 10/100Base-TX |
|---|---|
| Connector | RJ45 |
| Protocols | Modbus TCP server/slave |
| Max. Modbus TCP Masters/Clients Support | 15 (With TCP Socket Rollover Features) |
| No. of Ports | RS-485 x 1 (D+, D-, GND) |
|---|---|
| Protocols | Modbus RTU master |
| Serial Communication Parameters | Baud rate: 9600,19200,38400,57600,115200 Data bits - 8 bits, Stop bits - 1, 2 Parity bits - None, even, odd Common Specifications for Msc-RE-RS/MSC-RS-RS |
| Power Supply | 9 to 36V DC ±10% ; 24V DC ±10% @ 130 mA current (200mA Max.) |
|---|---|
| Power Consumption | <5W Watt ; 3 Watt (Max.) |
| Isolation (Between Supply and Communication Ports) | 1500VAC RMS ; 1000VAC RMS |
| Operating Temperature | 0°C to 55°C |
|---|---|
| Storage Temperature | -10°C to 70°C |
| Humidity | 30-95 %RH non-condensing |
| Status LEDs | 2 LEDs, (System status + communication status) & power status |
|---|
| Mounting | DIN-Rail (35mm) EN 60715 ; DIN Rail (35mm) EN 60715 |
|---|---|
| Enclosure Material | ABS |
| Dimension (in mm) | 75 (H) X 22.5 (W) X 110 (D) |
| Color | Light grey ; White |
| Weight | 150 g ; 100 g Approx.; Model; MSC-RE-RS Modbus Serial to Modbus TCP/IP Protocol Converte r; MSC-RS-RS Isolated RS-485 to RS-485 Repeater |
| Case | ABS |
| Module Dimension (in mm) | 88 (L) X 37 (W) X 59 (H) |
| Storage Temperature | -10 to 70 °C |
|---|---|
| Humidity | 30 to 95 % Non-condensing |
| Model MSC | Model; MSC XX XX; PS Profibus DP MS Modbus RTU |
|---|
| Communication | RS-485 half duplex |
|---|---|
| Speed | 1200 - 115200 bps |
| Connector | Terminal block |
| Status LEDs | 1 LED Power, 2 LED's communication status |
| Communication Speed (Baud Rate) | Auto baudrate detection |
|---|---|
| Signal Boost | up to 1200m (depends upon baud rate) |
| Maximum Nodes | 31 |
| Connector | Plug-in screw terminals, 1.5mm2 cable size |
| Recommended Cable | Shilded twisted pair, size: 0.14mm2 (Shield require to GND) |
| Applications | Data sharing between PLC, DCS, Controllers, Inverters and other network devices Operator Interfaces, Operator interfaces, Industrial / Factory / Process/Building Automation, Intelligent Field Sensors and Actuators Communication, Solar String / Environmental Monitoring |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.