Masibus 8204 4-Channel Scanner / Protection Relay
- Brand
- Masibus
- Model number
- 8204
- Category
- Process Indicators & Scanners
Masibus 8204 4-Channel scanner / protection relay: 4 inputs, input Ranges. For generator monitoring and protection, motor protection: winding & bearing temperature.
Price and availability on request
Key features
- Universal input for each Analog Input
- Compact 1/8 DIN mounting
- Front Panel Programming
- Fast Sampling rate with instantaneous relay action
- Four relays for alarm/trip
- RS485 Serial communication port for remote monitoring
- Multiple Levels of configuration and password protection
- Comprehensive Alarm/Trip logic programming
- Retransmission output (Optional)
Specifications
| No of Input | 4 |
|---|---|
| Input Type | Thermocouple (E, J, K, T, B, R, S, N), RTD (Pt-100, 3W), Current, Voltage, Serial Input |
| Display Range | Refer Table-1 |
| Sampling Rate | 0.1 / 1.0°C TC and Linear Input :100mSec/channel RTD Input: 200mSec/channel |
| CJC Error | ±2.0°C |
| Sensor Open | All inputs except 0-5VDC / 10VDC |
| Sensor Burnout current | 1.2µA |
| NMRR | 1 mA (Approx.) > 40dB |
| CMRR | > 120dB |
| Temp-co | < 100ppm/°C |
| Input Impedance | > 1MΩ Max Voltage 20VDC Display & Keys Process Value 4-digit, 0.56", Red seven segment LED |
| Channel No | 1-digit, 0.56", Green seven segment LED |
| Status | 4 Red LEDs for Relay status, 1 Red LED Manual mode status, 2 RED LEDs |
| Keys | Menu/Enter, Escape, Increment |
| No of Relays | 4 |
|---|---|
| Time Delay | 1 to 99 secs |
| Operation Mode | Internal: Physical AI Values, Modbus AI Values External: Direct Commands Through Modbus Master ; I nternal: Physical AI Values, Modbus AI Values External: Direct Commands Through Modbus Master |
| Current | 0/4-20mA @ 500Ω Max |
| Voltage | 0/1-5V, 0-10V @3KΩ Min |
| Interface | RS485 |
| Protocol | Modbus RTU |
| Baud Rate | 9600, 19200 |
| BSSRTD1-Busbar-LX | Busbar Temperature Sensor (PT100) |
|---|
| Dimension (in mm) Front Bezel (in mm) | 48(H) x 96(W) x 120(D) 48(H) x 96(W) |
|---|---|
| Panel Cutout (in mm) | 45(H) x 92(W) |
| Depth behind Panel | 112 mm |
| Enclosure | ABS Molded |
| Weight | 300 grams approx. |
| Terminal Cable size | IP20 2.5 mm2 |
| Storage Temperature | 0-80° C |
|---|---|
| Humidity | 30-95% RH non-condensing Table 1: Display Range |
| Input Type | Ranges |
| RTD | Pt-100 / -199.9 to 850.0° C |
| Linear | -10 - 20mV 0 - 75mV 0 - 100mV 0.4 - 2V DC 4-20 mA (Ext.100Ω) 0 - 2 VDC 0 - 20mA (Ext 100Ω) 0 - 5V 1 - 5V 0 - 10V / -1999 to 99 |
| Serial (RS | 485) PV write Facility / -1999 to 99; 0VDC N; 1 |
| Applications | Generator Monitoring and Protection, Monitoring of Air compressor, pump, transformers, fans and blowers DG temperature monitoring, Motor protection: Winding & Bearing temperature, Water and Waste-Water remote monitoring, Electrical Sub-station monitoring, Drying Ovens, Fermentation Processes, Flow Monitoring, Retorts and Cooking Processes, Heat Treatment: to achieve desired result of hardening or softening material, Power Monitoring, As a SCADA RTU, Metal and mining applications, Machine conditi |
|---|---|
| Industries | IIOT Industry 4, Power, Metal, Water, Panel Manufacturing, Chemical, Food, Paper, Pharma, Sugar |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.