Masibus 409 Process Indicator
- Brand
- Masibus
- Model number
- 409
- Category
- Process Indicators & Scanners
Masibus 409 process indicator. For temperature & process indication, pressure/ level/ flow monitoring.
Price and availability on request
Key features
- 5 digit 0.56" Display
- 21 selectable input types (TC, RTD, mV, mA, V, Ω)
- Transmitter Power Supply
- RS485 serial communication (optional)
- PV write facility via Serial input
- Programmable retransmission output (optional)
- Two independent programmable alarm output
- Digital Input-Reset PV min/max value
- Display brightness control
- Serial RS485 Input (Modbus Slave Read/Write)
- Input Scalability for Linear input type
- Square Root Extraction for linear input type
- Selectable Digital Filter 0-60 Sec
Specifications
| Input Type | Thermocouple (E, J, K, T, B, R, S), RTD (Pt100), Current, Voltage, Resistance |
|---|---|
| Display Range | Refer Table-1 |
| ADC Resolution | 17 bits |
| Display Resolution | 0.1°C/ 1 Count |
| Sampling Rate | 4 Samples/Sec |
| CJC Error | ±2.0 °C |
| Sensor open | All inputs except 0-5V, 0-10V, ± 10V, 0-20mA |
| Sensor Burnout current | 0.5uA (Approx.) |
| RTD excitation current | 0.8 mA (Approx.) |
| NMRR | > 40 dB |
| CMRR | 100 dB; < 100ppm for Input to Display |
| Temp-co | < 150ppm for retransmission output |
| Input Impedance | > 1MΩ for TC, 0-2V, 0.4-2V, 0-75mV, ± 75mV; >840 kΩ for 0-5V, 1-5V, 0-10V, ±10V |
| Max Voltage | 20VDC |
| Process Value | 0.56" 5 digit Seven segment Red LED |
|---|---|
| Status Indication | 4 Red LED's for Alarm and Tx/Rx |
| Relays | 2 Nos. |
|---|---|
| Rating | 5A @ 230VAC / 30VDC |
| Voltage | 0/1-5V, 0-10V @2KΩ Min. Accuracy 0.25% of FS Transmitter Power Supply 24VDC (±10%) @26mA |
|---|
| Standard | 85-265VAC/ 125-300VDC |
|---|---|
| ORDER | IN |
| Enclosure Protection | IP20 |
|---|---|
| Mounting | Panel Mount |
| Dimensions(in mm) | 96(W) x 48(H) x 112(D) Panel Cutout(in mm) 92 x 46 |
|---|---|
| Weight | 260 g (Approx.) |
| Terminal Cable Size | 2.5 mm2 |
| Standard Accessories | 2 Nos. Clamp |
| Storage temperature | 0-80 °C Humidity 20-95 %RH non-ocndensing Table-1: Display Range |
|---|
| RTD | Pt-100 -199.9 to 850.0°C |
|---|---|
| Resistance | 0 - 400Ω -19999 to 99999 0 - 6000Ω 1-5V /4-20mA 0-5V/0-20mA 0-2V 0.4-2V Linear ±10 V -19999 to 99999 0 - 10 V -10-20mV ±75 mV 0-75mV |
| Serial (RS485) | PV write Facility -19999 to 19999 |
| r Supply | Communication / Retransmission o/p; X X |
|---|
| Applications | Temperature & process indication, Pressure/ Level/ Flow Monitoring, Plastics molding/extrusion temperature monitoring, Heat treatment - furnace temperature monitoring, Weighing Measurement |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.