Lutron PTM-9957 Temperature Controller / Monitor, Thermocouple and Pt100

Brand
Lutron
Model number
PTM-9957

Panel temperature controller for type K/J/T/E/R/S thermocouples and Pt 100, with 0.1 degree resolution, control and Hi/Lo alarm relays.

Price and availability on request

Request a quote

Sent with the product details: Lutron PTM-9957 Temperature Controller / Monitor, Thermocouple and Pt100.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Thermocouple Temp. sensor: type K/J/T/E/R/S.
  • Pt Temp. sensor: Pt 100 ohm.
  • Type K range: -100 to 1300 °C, °C/°F. Type J range: -100 to 1150 °C, °C/°F. Type T range: -100 to 400 °C, °C/°F. Type E range: -100 to 900 °C, °C/°F. Type R range: 0 to 1700 °C, °C/°F. Type S range: 0 to 1500 °C, °C/°F.
  • Pt 100 ohm range: -199 to 850 °C, °C/°F.
  • Resolution: 0.1 degree (< 1000 degree) 1 degree (≧1000 degree)
  • Control setting, Hi/Lo alarm setting.
  • Control relay output, alarm relay output.
  • Control Relay will make action when the reading value reach to control value.
  • Alarm Relay will make action when the reading value reach to high/low alarm value.
  • Hysteresis value setting for control and alarm function.
  • PoMicroprocessor circuit ensures high accuracy and provides special functions and features.
  • Power: 90 ACV to 264 ACV, 50/60 Hz.
  • RS-232/USB computer interface.
  • DIN size: 96 x 48 mm. Depth: 107 mm.
  • Optional type K probe: TP-01, TP-02A, TP-03, TP-04, TP-05.
  • Optional Pt 100 ohm probe: TP-100B.
  • Optional USB cable, USB-01.
  • Optional date acquisition software,SW-U801-WIN.

Specifications

Specifications
CircuitCustom chip of microprocessor LSI circuit.
Display4 digits red LED, digit size : 14 mm.
MeasurementPt 100 ohm range : -199 to 850 °C, °C/°F.; Type K range : -100 to 1300 °C, °C/°F.; Type J range : -100 to 1150 °C, °C/°F.; Type T range : -100 to 400 °C, °C/ °F.; Type E range : -100 to 900 °C, °C/°F.; Type R range : 0 to 1700 °C, °C/°F.; Type S range : 0 to 1500 °C, °C/°F.
Update Time of DisplayApprox. 1 second.
Data OutputRS 232 PC serial interface.
Operating temperature0 to 50°C.
Operating humidityLess than 80% R.H.
Power Supply90 to 260 ACV, 50/60 Hz.
Power ConsumptionApprox. 3.3 VA/AC 110V.; Approx. 5.5 VA/AC 220V.
Weight384 g/ 0.84 LB.
DimensionDIN size : 96 x 48 mm; Depth : 110 mm.
Setting value1st layer setting procedures: CtLo ( Control low limit ); CtHi ( Control high limit ); ALLo ( Alarm low limit ); ALHi ( Alarm high limit ); Second layer setting procedures: tyPE ( Sensor type ); dEG ( °C/°F ); FiLt ( Digital filter ); CtHy ( Control hysteresis set ); ALHy ( Alarm hysteresis set ); oFSt ( Offset adjustment ); GAin ( Gain adjustment )
Relay outputsNumber : 2 relays; Function : Relay 1 : Unit 1 control relay.; Relay 2 : High/Low alarm relay.; Max load : 0.5 ACA/250 ACV; 0.5 DCA/24 DCV; * Do not apply the relay contact load current > 0.5 A, other wise the relay may be damaged permanently without warranty.
Accessories
Supplied with* Instruction manual : 1 PC; * Case holder with screw : 2 PCs
OptionalType K Temp. probe : TP-01, TP-02A, TP-03, TP-04, TP-05; Pt 100 ohm Temp. probe : TP-100B.; * Data Acquisition software; SW-U801-WIN.; * RS232 cable, UPCB-02.; * USB cable, USB-01.; * Real time SD card datalogger; DL-9602SD; * GSM controller, GSM-889.; * Interface cable ( cable between meter to GSM-889 ), GMCB-89.
Measurement Range and Resolution
Range-199.9 to 850.0°C / -327.0 to 1562.0°F
Resolution0.1°C (below 1000°C) / 1°C (1000°C and above)
Accuracy±⁠(0.4% + 1°C) / ±⁠(0.4% + 1.8°F) below 1000°C / ±⁠(0.4% + 2°F) above 1000°F
Type K-100 to 1300°C / -148 to 2372°F
Type J-100 to 1150°C / -148 to 2102°F
Type T-100 to 400°C / -148 to 752°F
Type E-100 to 900°C / -148 to 1652°F
Type R0 to 1700°C / 32 to 3092°F
Type S0 to 1500°C / 32 to 2732°F

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.