Lutron PTM-9957 Temperature Controller / Monitor, Thermocouple and Pt100
- Brand
- Lutron
- Model number
- PTM-9957
- Category
- Temperature Controllers
Panel temperature controller for type K/J/T/E/R/S thermocouples and Pt 100, with 0.1 degree resolution, control and Hi/Lo alarm relays.
Price and availability on request
Key features
- Thermocouple Temp. sensor: type K/J/T/E/R/S.
- Pt Temp. sensor: Pt 100 ohm.
- Type K range: -100 to 1300 °C, °C/°F. Type J range: -100 to 1150 °C, °C/°F. Type T range: -100 to 400 °C, °C/°F. Type E range: -100 to 900 °C, °C/°F. Type R range: 0 to 1700 °C, °C/°F. Type S range: 0 to 1500 °C, °C/°F.
- Pt 100 ohm range: -199 to 850 °C, °C/°F.
- Resolution: 0.1 degree (< 1000 degree) 1 degree (≧1000 degree)
- Control setting, Hi/Lo alarm setting.
- Control relay output, alarm relay output.
- Control Relay will make action when the reading value reach to control value.
- Alarm Relay will make action when the reading value reach to high/low alarm value.
- Hysteresis value setting for control and alarm function.
- PoMicroprocessor circuit ensures high accuracy and provides special functions and features.
- Power: 90 ACV to 264 ACV, 50/60 Hz.
- RS-232/USB computer interface.
- DIN size: 96 x 48 mm. Depth: 107 mm.
- Optional type K probe: TP-01, TP-02A, TP-03, TP-04, TP-05.
- Optional Pt 100 ohm probe: TP-100B.
- Optional USB cable, USB-01.
- Optional date acquisition software,SW-U801-WIN.
Specifications
| Circuit | Custom chip of microprocessor LSI circuit. |
|---|---|
| Display | 4 digits red LED, digit size : 14 mm. |
| Measurement | Pt 100 ohm range : -199 to 850 °C, °C/°F.; Type K range : -100 to 1300 °C, °C/°F.; Type J range : -100 to 1150 °C, °C/°F.; Type T range : -100 to 400 °C, °C/ °F.; Type E range : -100 to 900 °C, °C/°F.; Type R range : 0 to 1700 °C, °C/°F.; Type S range : 0 to 1500 °C, °C/°F. |
| Update Time of Display | Approx. 1 second. |
| Data Output | RS 232 PC serial interface. |
| Operating temperature | 0 to 50°C. |
| Operating humidity | Less than 80% R.H. |
| Power Supply | 90 to 260 ACV, 50/60 Hz. |
| Power Consumption | Approx. 3.3 VA/AC 110V.; Approx. 5.5 VA/AC 220V. |
| Weight | 384 g/ 0.84 LB. |
| Dimension | DIN size : 96 x 48 mm; Depth : 110 mm. |
| Setting value | 1st layer setting procedures: CtLo ( Control low limit ); CtHi ( Control high limit ); ALLo ( Alarm low limit ); ALHi ( Alarm high limit ); Second layer setting procedures: tyPE ( Sensor type ); dEG ( °C/°F ); FiLt ( Digital filter ); CtHy ( Control hysteresis set ); ALHy ( Alarm hysteresis set ); oFSt ( Offset adjustment ); GAin ( Gain adjustment ) |
| Relay outputs | Number : 2 relays; Function : Relay 1 : Unit 1 control relay.; Relay 2 : High/Low alarm relay.; Max load : 0.5 ACA/250 ACV; 0.5 DCA/24 DCV; * Do not apply the relay contact load current > 0.5 A, other wise the relay may be damaged permanently without warranty. |
| Supplied with | * Instruction manual : 1 PC; * Case holder with screw : 2 PCs |
|---|---|
| Optional | Type K Temp. probe : TP-01, TP-02A, TP-03, TP-04, TP-05; Pt 100 ohm Temp. probe : TP-100B.; * Data Acquisition software; SW-U801-WIN.; * RS232 cable, UPCB-02.; * USB cable, USB-01.; * Real time SD card datalogger; DL-9602SD; * GSM controller, GSM-889.; * Interface cable ( cable between meter to GSM-889 ), GMCB-89. |
| Range | -199.9 to 850.0°C / -327.0 to 1562.0°F |
|---|---|
| Resolution | 0.1°C (below 1000°C) / 1°C (1000°C and above) |
| Accuracy | ±(0.4% + 1°C) / ±(0.4% + 1.8°F) below 1000°C / ±(0.4% + 2°F) above 1000°F |
| Type K | -100 to 1300°C / -148 to 2372°F |
| Type J | -100 to 1150°C / -148 to 2102°F |
| Type T | -100 to 400°C / -148 to 752°F |
| Type E | -100 to 900°C / -148 to 1652°F |
| Type R | 0 to 1700°C / 32 to 3092°F |
| Type S | 0 to 1500°C / 32 to 2732°F |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.