Lutron PPS-9312 Pressure Controller / Monitor
- Brand
- Lutron
- Model number
- PPS-9312
- Category
- Process Indicators & Scanners
Panel pressure controller for 2 to 400 bar sensors with many units, a large red LED display and control and alarm relays.
Price and availability on request
Key features
- Meter connects with 2, 5, 10, 20, 50, 100, 400 bar sensor, no calibration procedures are necessary typically when change a new sensor.
- Unit select: Bar, PSI, Kg/cm^2, inch Hg, mm Hg, inch H2O, meter H2O, Atmosphere, hPa, KPa.
- Large red LED display, high brightness and easy to read.
- Control setting, Hi/Lo alarm setting.
- Control relay output, alarm relay output.
- Alarm Relay will make action when the reading value reach to high/low alarm value.
- Control Relay will make action when the reading value reach to control value.
- Hysteresis value setting for control and alarm function.
- Microprocessor circuit ensures high accuracy and provides special functions and features.
- Power: 90 ACV to 264 ACV, 50/60 Hz.
- Cooperate the 4-20 mA pressure input, sensor can install in the faraway position.
- DC 12V output, used for the power of pressure sensor.
- RS-232/USB computer interface.
- DIN size: 96 x 48 mm. Depth: 107 mm.
- Optional pressure sensor, TR-PS2W-xxBAR, PS93MA-xxBAR.
- Optional USB cable, USB-01.
- Optional data acquisition software.
- Optional GSM controller.
Specifications
| Circuit | Custom chip of microprocessor LSI circuit. |
|---|---|
| Display | 4 digits red LED, digit size : 14 mm.; x 10, x100 indicator |
| Measurement | procedures : Meter connects with 2, 5, 10, 20, 50, 100, 400 bar sensor. |
| Datalogger Sampling Time | Approx. 1 second. |
| Data Output | RS 232 PC serial interface. |
| Operating temperature | 0 to 50°C. |
| Operating humidity | Less than 80% R.H. |
| Power Supply | 90 to 260 ACV, 50/60 Hz. |
| Power Consumption | Approx. 5.3 VA/AC 110V.; Approx. 7.3 VA/AC 220V. |
| Weight | 384 g/ 0.84 LB. |
| Dimension | DIN size : 96 x 48 mm.; Depth : 110 mm. |
| Setting value | 1st layer setting procedures : CtLo ( Control low limit ); CtHi ( Control high limit ); ALLo ( Alarm low limit ); ALHi ( Alarm high limit ); Second layer setting procedures : tyPE ( Sensor type ); FiLt ( Digital filter ); CtHy ( Control hysteresis set ); ALHy ( Alarm hysteresis set ); oFSt ( Offset adjustment ); GAin ( Gain adjustment ); Unit ( Unit set ) |
| Relay outputs | Number : 2 relays; Function : Relay 1 : Control relay.; Relay 2 : High/Low alarm relay.; Max load : 0.5 ACA/250 ACV; 0.5 DCA/24 DCV; * Do not apply the relay contact load current > 0.5 A, other wise the relay may be damaged permanently without warranty. |
| Supplied with | Instruction manual : 1 PC; Case holder with screw : 2 PCs |
|---|---|
| Optional | Two wires pressure transmitters; Model : TR-PS2W-xx BAR; Range : 2, 5, 10, 20, 50, 100; 400 BAR.; * Data Acquisition software; SW-U801-WIN.; * RS232 cable, UPCB-02.; * USB cable, USB-01.; * Real time SD card datalogger; DL-9602SD; * GSM controller, GSM-889.; * Interface cable ( cable between meter to GSM-889 ), GMCB-89. |
| Accuracy | ±(0.5% + 2d) (meter only, within 23 ± 5°C) |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.