Lutron DW-6195 3 Phase Power Analyzer with Harmonics, DW-6195

Brand
Lutron
Model number
DW-6195

Three-phase power analyzer with harmonic measurement for 1P/2W to 3P/4W systems, supplied with three CP-1201 clamp probes.

Price and availability on request

Request a quote

Sent with the product details: Lutron DW-6195 3 Phase Power Analyzer with Harmonics, DW-6195.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Analysis for 3 phase multi-power system, 1P/2W, 1P/3W, 3P/3W, 3P/4W. Voltage and Current are the True RMS value.
  • 3 current probes (CP-1201) are included, if change the current probes, the calibration procedures are not necessary.
  • Current probe input signal/ranges with selection: Input signal (ACV): 200 mV/300 mV/500 mV/1 V/2 V/3 V. Ranges (ACA): 20 A/200 A/2000 A/30 A/300 A/ 3000 A 60A/600A/6000A
  • Meter can cooperate the universal current probes.
  • Complete set with 4 PCs Test Leads, 4 PCs Alligator clips, 3 PCs Clamp Probe (CP 1201), AC to DC 9V adapter, 2 G SD memory card and Carrying bag.
  • Measurement: V (phase-to-phase), V (phase-to-ground) A (phase-to-ground) KW / KVA / KVAR / PF (phase) KW / KVA / KVAR / PF (system) KWH / KVAH / KVARH / PFH (system) Phase angle
  • Harmonics display (1-50th order).
  • Simultaneous display of Harmonics and Waveform.
  • Display of Waveform with Peak Values.
  • Analysis of Total Harmonic Distortion (THD).
  • Graphic Phase diagram with 3-Phase system parameters.
  • 3 phase Voltage or Current Unbalanced Ratio (VUR, AUR) and Unbalanced Factor.
  • Calculated Unbalanced Current through Neutral Line (An)
  • Capture Transient events (including Dip, Swell and Outage) with programmable threshold (%).
  • Programmable CT ratio (1 to 600) and PT ratio (1 to 1000).
  • ACV input impedance is 10 Mega ohms.
  • Safety Standard: IEC 1010, CAT III 600V.
  • Built-in clock and Calendar, real time data record with SD memory card, sampling time set from 2 to 7200 seconds. Just slot in the SD card into the computer, it can down load the all the measured value with the time information (year, month, data, hour, minute, second) to the Excel directly, then user can make the further data analysis by themselves.
  • Powered by AA (UM-3) DC 1.5 V X 8 batteries (Alkaline type) or DC 9V adapter.
  • Computer data output, can cooperate with optional USB Cable/USB-01, RS232 cable/UPCB-02 and Data Acquisition software, SW-811,SW-U811
  • Optional current probes: CP-1201, CP-2000, CP-200, CP-3000,CP-3001,CP-6001 detail specification.
  • User can order the meter only (without the current probes) with the special request as intend to cooperate their own current probes.
  • Patented.

Specifications

Specifications
CircuitCustom one-chip of microprocessor LSI circuit
Display* LCD Size : 81.4 X 54 mm ( 3.2 X 2.1 inch ); * TFT LCD (320 X 240 pixels ) with back light.
Measurement Unit* V (phase-to-phase); * V (phase-to-ground); * A (phase-to-ground); * KW / KVA / KVAR / PF (phase); KW / KVA / KVAR / PF (system); KWH / KVAH / KVARH / PFH (system); * Power factor; * Phase angle; * Frequency; * Harmonics display.
Sampling TimeApprox. 1 second.
Data HoldFreeze the display reading.
Data outputRS232 computer serial interface : * Connect the optional USB cable; USB-01 will get the USB plug.; * Connect the optional RS232 cable; UPCB-02 will get the RS232 plug.
Operating Temperature0 to 50°C ( 32 to 122°F ).
Operating HumidityLess than 80% R.H..
Power Supply* DC 1.5V, AA ( UM-3 ) Battery X 8 PCs (Alkaline or heavy-duty battery).; * AC to DC 9V power adapter.
Power Consumption* Meter : 362 DCmA.; * Clamp : 22 DCmA.
Weight* Meter : 840g ( meter only ); * Clamp ( includded cable ) : 500g
DimensionMeter : 225 X 125 X 64 mm ( 8.86 X 4.92 X 2.52 inch ); Clamp : 210 X 64 X 33mm ( 8.3 X 2.5 X 1.3 inch ); Clamp Jaw : 86 mm (3.4 inch)- outside
Wire connections1P/2W, 1P/3W, 3P/3W, 3P/4W.
Voltage ranges10 ACV to 600 ACV, auto range.
Current ranges* Current probe input signal volage ( ACV ) : 200mV/300mV/500mV/1V/2V/3V.; * Current probe input current range ( ACA ) : 20 A/200A/2000A (1200 A)/30A/300A/3000A; 60A/600A/6000A; * Meter can cooperate the universal current probe.
Safety standardIEC1010 CAT III 600 V.
ACV input impedance10 Mega ohms.
Range selectACV Auto range.; ACA Manual range.
Clamp frequency response40 Hz to 1 KHz.
Spec. tested frequency45 to 65 Hz.
Over load protectionACV :720 ACV rms; ACA :1300 ACA with clamp probe; * For the Clamp,CP-1201
Over Indicator* LCD display show " OL ".; * The data save into the SD card will show " 9999 " or " 999 " ( overleap; the decimal point ).
Under Indicator* The data save into the SD card will show " 9999 " or " 999 " ( overleap; the decimal point ).
Data RecordSD Card Record.
Power ON/OFFManual OFF by push button.
Real time data logger* Real time data logger, saved the data into SD memory card and down load the all the measured value with the time information; ( year/month/data/hour/minute/second ) down load to the Excel; * Sampling time for data logger : 2 seconds to 7200 seconds, the during of setting step are 2 seconds.
Clamp max. conductor Size50 mm ( 2.0 inch ) Dia.; * For the Clamp,CP-1201
Accessories
Supplied with* Instruction Manual (1 PC); * Test Leads (1 Set, 4 PCs); * Alligator Clips (1 Set, 4 PCs); * Clamp Probes (3 PCs, CP-1201); * AC to DC 9V Adapter (1 PC); * SD Card (4 GB); * Carrying Bag (1 PC)
Optional* 2000 Amp current probe, CP-2000; * 200 Amp current probe, CP-200; * 1200 Amp current probe, CP-1201; * Flexible 3000 Amp current probe, CP-3000, CPF-3002,CP-3001, CP-6001; * USB Cable, USB-01; * RS232 cable, UPCB-02; * Data Acquisition software, SW-U811
Voltage Measurement
Range10.0V to 600.0V
Resolution0.1V
Accuracy± (0.5% + 0.5V)
Current Measurement
Resolution0.001A to 1A
AccuracyVaries with range and probe (e.g., ± (1% + 0.1A) for 20A range)
Power Factor
Range0.00 to 1.00
Resolution0.01
Accuracy± 0.04
Phase Angle (Φ)
Range-180° to 180°
Resolution0.1°
Frequency
Resolution0.1 Hz
Accuracy± 0.1 Hz

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.