Lutron DW-6093 3 Phase Power Analyzer, Universal Current Probes
- Brand
- Lutron
- Model number
- DW-6093
Three-phase power analyzer for 1P/2W to 3P/4W systems that accepts universal current probes, measuring true power, apparent and reactive power and energy.
Price and availability on request
Key features
- Analysis for 3 phase multi-power system, 1P/2W, 1P/3W, 3P/3W, 3P/4W
- Voltage & Current are the True RMS value.
- True Power (KW、MW、GW) measurement.
- Apparent Power (KVA、MVA、GVA) measurement.
- Reactive Power (KVAR MVAR、GVAR) measurement.
- Watt-Hour (WH、SH、QH、PFH).
- Power Factor(PF)、Phase Angle(Φ).
- Voltage measurement range: 10 to 600 ACV
- Current probe input signal volage (ACV): 200 mV/300 mV/500 mV/1 V/2 V/3 V. Current probe input current range (ACA): 20 A/200 A/2000 A (1200 A)/30 A/300A /3000 A.
- Meter can cooperate the universal current probe.
- Programmable CT ratio (1 to 600) and PT ratio (1 to 1000).
- ACV input impedance is 10 Mega ohms.
- Safety Standard: IEC 1010, CAT III 600V
- Built-in clock and Calendar, real time data record with SD memory card, sampling time set from 2 to 7200 seconds. Just slot in the SD card into the computer, it can down load the all the measured value with the time information (year/month/data/ hour/minute/second) to the Excel directly, then user can make the further data analysis by themselves.
- Complete set with 4 PCs Test Leads, 4 PCs Alligator clips, 3 PCs Clamp Probe (CP-1201), AC to DC 9V adapter, 2 G SD memory card and Carrying bag.
- Computer data output, can cooperate with USB Cable /USB-01 RS232 cable/UPCB-02 and Data Acquisition software, SW-U811-WIN.
Specifications
| Circuit | Custom one-chip of microprocessor circuit |
|---|---|
| Display | * LCD Size : 81.4 X 61 mm ( 3.2 X 2.4 inch ); * Dot Matrix LCD (320 X 240 pixels ) with back light. |
| Measurement Unit | * ACV Power factor; * ACA; * AC WATT ( True Power ); AC WATT( Apparent Power ); AC WATT( Reactive Power ); * Power factor; * Phase angle; * Frequency |
| Data Output | RS232 computer serial interface : * Connect the optional USB cable; USB-01 will get the USB plug.; * Connect the optional RS232 cable; UPCB-02 will get the RS232 plug. |
| Sampling Time | Approx. 1 second. |
| Data Hold | Freeze the display reading. |
| Operating Temperature | 0 to 50°C ( 32 to 122°F ). |
| Operating Humidity | Less than 80% R.H.. |
| Power Supply | * DC 1.5V, AA ( UM-3 ) Battery X 8 PCs; (Alkaline or heavy-duty battery).; * AC to DC 9V power adapter. |
| Power Consumption | * Meter : 300 DCmA.; * Clamp : 34 DCmA. |
| Weight | * Meter : 948g ( includes batteries ); * Clamp ( includded cable ) : 467g |
| Dimension | Meter : 225 X 125 X 64 mm ( 8.86 X 4.92 X 2.52 inch ); Clamp : 210 X 64 X 33mm ( 8.3 X 2.5 X 1.3 inch ); Clamp Jaw : 86 mm (3.4 inch)- outside |
| Wire connections | 1P/2W, 1P/3W, 3P/3W, 3P/4W. |
| Voltage ranges | 10 ACV to 600 ACV, auto range. |
| Current ranges | * Current probe input signal volage ( ACV ) : 200mV/300mV/500mV/1V/2V/3V.; * Current probe input current range ( ACA ) : 20 A/200A/2000A (1200 A)/30A/300A/3000A; * Meter can cooperate the universal current probe. |
| Safety standard | IEC1010 CAT III 600 V. |
| ACV input impedance | 10 Mega ohms. |
| Range select | ACV : Auto range.; ACA : Manual range. |
| Clamp frequency response | 40 Hz to 1 KHz. |
| Spec. tested frequency | 45 to 65 Hz. |
| Over load protection | ACV 720 ACV rms; ACA 1300 ACA with clamp probe; * For the Clamp,CP-1201 |
| Over Indicator | * LCD display show " OL ".; * The data save into the SD card will show; " 9999 " or " 999 " ( overleap the decimal point ). |
| Under Indicator | * LCD display show " UR ".; * The data save into the SD card will show " 9999 " or " 999 " ( overleap the decimal point ). |
| Data Record | SD Card Record. |
| Power ON/OFF | Manual OFF by push button. |
| Real time data logger | * Real time data logger, saved the data into SD memory card and down load the all the measured value with the time information (year/month/data/hour/minute/second ) down load to the Excel; * Sampling time for data logger : 2 seconds to 7200 seconds, the during of setting step are 2 seconds. |
| Supplied with | * Instruction Manual (1 PC); * Test Leads (1 Set, 4 PCs); * Alligator Clips (1 Set, 4 PCs); * Clamp Probes (3 PCs, CP-1201); * AC to DC 9V Adapter (1 PC); * SD Card (4 GB); * Carrying Bag (1 PC) |
|---|---|
| Optional | * 2000 Amp current probe, CP-2000; * 200 Amp current probe, CP-200; * Flexible 3000 Amp current probe, CP-3000; * USB Cable, USB-01; * RS232 cable, UPCB-02; * Data Acquisition software, SW-U811 |
| Range | 10.0V to 600.0V |
|---|---|
| Resolution | 0.1V |
| Accuracy | ± (0.5% + 0.5V) |
| Resolution | 0.001A to 1A |
|---|---|
| Accuracy | Varies with range and probe (e.g., ± (1% + 0.1A) for 20A range) |
| Range | 0.00 to 1.00 |
|---|---|
| Resolution | 0.01 |
| Accuracy | ± 0.04 |
| Range | -180° to 180° |
|---|---|
| Resolution | 0.1° |
| Resolution | 0.1 Hz |
|---|---|
| Accuracy | ± 0.1 Hz |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.