Bench multimeter with 6000 counts for voltage, current, resistance, frequency and more, with isolated RS232 output and SD card logging.

Price and availability on request

Request a quote

Sent with the product details: Lutron DM-9971SD Bench Digital Multimeter, SD Card Logger.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • High Accuracy Measurement: 6000 counts A/D for high resolution, supporting measurements for DCV, ACV, DCA, ACA, resistance, frequency, duty cycle, diode, and continuity beeper.
  • Versatile Connectivity: Equipped with RS232 computer serial interface (photo couple) and accepts SD memory cards up to 32 GB capacity for extensive data logging.

Specifications

Specifications
Display97 mm x 56 mm large LCD display
MeasurementDCV, ACV, DCA, ACA, Resistance,Diode, Continuity beeper, Frequency, Duty cycle.
Datalogger Sampling Time Setting rangeAuto; 2 seconds to 3600 seconds; Manual; Push the data logger button once will save data one time.; @Set the sampling time to 0 seconds.
Data error no.≤ 0.1% no. of total saved data typically.
SD card capacity2 GB to 32 GB
A/D counts no.6000 counts.
Range selectionAuto range with manual range selecting.
Special functionRelative measurement, Data hold
Data holdTo freeze the display reading on the LCD display.
Power On/Off managementAuto power of or manual power off.
Memory recallRecords Maximum & Minimum readings with recall.
Relative measurementTo offset the measurement value.
V/A/Hz buttonWhen execute the voltage or current function also can measure the frequency of signal.
Data outputRS 232 PC serial interface, photo couple.
PolarityAutomatic Switching, " - " indicates negative polarity.
Zero adjustmentAutomatic.
Sampling time of displayApprox. 0.5 to 1 second.
Operating Temperature0 °C to 50 °C (32 °F to 122 °F)
Operating HumidityMax. 80% RH.
Power supplyDC1.5 V (AA) battery x 6 PCs or DC 9V adapter input * AC/DC Power adapter is optional.
Power consumptionNormal operation (w/o SD card save data) : Approx. DC 80 mA; When SD card save the data : Will increase approx. DC 25 mA.
Dimension292 x 236 x 100 mm ( 11.5 x 9.3 x 3.9 inch ).
Weight1450 g/3.19 LB ( w.o battery ).
Accessories
Supplied withIncluded; Red and Black Test Leads; ( CAT III 1KV Test Leads ):1 Set; 630 mA Spare Fuse.:1 PC; Instruction Manual:1 PC
OptionalFull line adapters : ACA/DCA current adapter, Tachometer adapter, Humidity adapter, Pressure adapter, Light adapter, EMF adapter, Light adapter, EMF adapter; AC to DC 9V Adaptre : AP-9VA; RS232 cable to D-Sub 9 connector: UPCB-06 RS232 cable to USB connector:.USB-11; SD card.:SD-4GB; Data Acquisition software: SW-U801-WIN
Measurement Range and Resolution
Range600.0 mV / 6 V / 60 V / 600 V / 1000 V
Resolution0.1 mV / 0.001 V / 0.01 V / 0.1 V / 1 V
Accuracy±⁠(0.5% + 2d) for 600 mV, ±⁠(0.8% + 1d) for 6 V, 60 V, 600 V, 1000 V
Input Impedance10 MΩ
Overload Protection600 mV range ± 380 DCV, 380 ACV; other ranges ± 1000 DCV, 1000 ACV
Accuracy±⁠(1% + 2d) (specifications tested under 50/60 Hz)
Range10 A / 6 A / 600 mA / 60 mA / 6000 μA / 600 μA
Resolution0.01 A / 0.001 A / 0.1 mA / 0.01 mA / 1 μA / 0.1 μA
AccuracyDCA ±⁠(0.5% + 2d) to ±⁠(1.5% + 2d); ACA ±⁠(1% + 7d) to ±⁠(1.5% + 2d) (specifications tested under 50/60 Hz)
Overload Protection10 A range: 10 A fuse; μA, mA range: 630 mA fuse
Range600 Ω / 6 kΩ / 60 kΩ / 600 kΩ / 6 MΩ / 60 MΩ
Resolution0.1 Ω / 0.001 kΩ / 0.01 kΩ / 0.1 kΩ / 0.001 MΩ / 0.01 MΩ
Accuracy600 Ω ±⁠(1% + 2d); 6 kΩ, 60 kΩ, 600 kΩ, 6 MΩ ±⁠(1.5% + 2d); 60 MΩ ±⁠(3% + 5d)
Overload Protection±350 DCV, 350 ACV
Range60 Hz / 600 Hz / 6 kHz / 60 kHz / 600 kHz / 6 MHz / 20 MHz
Resolution0.01 Hz / 0.1 Hz / 0.001 kHz / 0.01 kHz / 0.1 kHz / 0.001 MHz / 0.01 MHz
SensitivityMin. 1 V rms, Max. 5 V rms
Range2.9 V DC
Continuity BeeperBeeps if measured resistance is less than 20 Ω