Lutron DM-9950 Smart Digital Multimeter, 6000 Counts

Brand
Lutron
Model number
DM-9950

Smart multimeter with five intelligent functions that pick AC or DC and the range automatically, 6000 counts, capacitance and frequency; CAT III 1000 V.

Price and availability on request

Request a quote

Sent with the product details: Lutron DM-9950 Smart Digital Multimeter, 6000 Counts.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Meet IEC 1010 CAT III 1000 V safety requirement.
  • 6000 counts A/D, high resolution.
  • ACV, ACA, DCV, DCA, ohms, continuity, Hz, Capacitance, Diode.
  • Smart function, Auto range or manual range with hold.
  • Smart operation, Build in 5 intelligent function: " V ", " Ω "," uA ", " mA "," A ".
  • " V " function can select ACV, DCV automatically with auto range.
  • " Ω " function can select the Resistance, Diode, Continuity beeper, Capacitance automatically with auto range.
  • " 10A "and " mA " and " uA " function can measure ACA, DCA with auto range.
  • Data hold.
  • Auto shut off is available to save battery life.
  • Both 10 A, mA,uA current range are build fuses for safety consideration.
  • 10 M ohm impedance for voltage circuit.
  • Built-in overload protection for most ranges.
  • LSI circuit provides high reliability and durability.
  • Uses durable, long-lasting components, enclosed in strong, light weight ABS-plastic housing.
  • Full line optional adapters: Clamp adapter, Pressure adapter, Sound level adapter Anemometer adapter,Light adapter, EMF adapter.

Specifications

Specifications
Display65 mm x 48 mm large LCD display
Range- Measurement Range: - DC Voltage: 600.0 mV, 6 V, 60 V, 600 V, 1000 V; - AC Voltage: 600.0 mV, 6 V, 60 V, 600 V, 1000 V; - DC Current: 600 µA, 6000 µA, 60 mA, 600 mA, 10 A; - AC Current: 600 µA, 6000 µA, 60 mA, 600 mA, 10 A; - Resistance: 600 Ω, 6 KΩ, 60 KΩ, 600 KΩ, 6 MΩ, 60 MΩ; - Capacitance: 6 nF, 60 nF, 600 nF, 6 µF, 60 µF, 600 µF; - Frequency: 40 Hz to 1 KHz
Operating Temp.0 °C to 50 °C (32 °F to 122 °F)
Operating HumidityMax. 80% RH.
Power SupplyDC 9 V battery, 006P,MN1604
Dimension190 x 88 x 40 mm ( 7.5 x 3.5 x 1.6 inch ).
Weight377 g/0.83 LB ( w.o battery ).
MeasurementDCV, ACV, DCA, ACA, Resistance, Capacitance, Frequency, Diode, Continuity beeper.
A/D counts no.6000 counts.
Range selectionSmart function or auto function.; manual range selecting.
Data holdTo freeze the display reading on the LCD display.
Power On/Off managementAuto power off or manual power off.
Memory recallRecords Maximum & Minimum readings with recall.
V/A/Hz buttonWhen execute the voltage or current function also can measure the frequency; of signal.
PolarityAutomatic Switching, " - " indicates negative polarity.
Sampling time of displayApprox. 0.5 to 1 second.
Power consumptionApprox. DC 3 mA.
Accessories
Supplied withRed and Black Test Leads; ( CAT III 1KV Test Leads ): 1 Set; 0.63 Amp Spare Fuse: 1 PC; Instruction Manual: 1 PC
OptionalFull line adapters : ACA/DCA current adapter; Pressure adapter,Light adapter; EMF adapter,Sound level adapter; High voltage probe.; Soft carrying case: CA-05A
Accuracy
DC Voltage± (0.5% + 2d) for 600mV, ± (0.8% + 1d) for 6 V to 1000 V.
AC Voltage± (1.0 % + 2d) * Spec. are tested under 50/60 Hz.
DC/AC Current± (1.5% + 2d) for 600/6000 µA, ± (1.0% + 2d) for 60/600 mA, ± (1.5% + 2d) for 10A
Resistance± (1% + 2d) to ± (3% + 2d) depending on range
Capacitance± (3% + 5d)
Frequency± (0.5% + 2d)
Overload Protection
DC Voltage600 mV range ± 500 DCV, 350 ACV; other ranges ± 1000 DCV, 1000 ACV
AC Voltage600 mV range ± 500 DCV, 350 ACV; other ranges ± 1000 DCV, 1000 ACV
DC Current10 A fuse for 10A range; 630 mA fuse for uA, mA ranges
AC Current10 A fuse for 10A range; 630 mA fuse for uA, mA ranges

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.