HTC Instruments DM-97 True RMS Digital Multimeter
- Brand
- HTC Instruments
- Model number
- DM-97
- Category
- Digital Multimeters
3¾-digit (3,999 count) true RMS auto-ranging digital multimeter with NCV, max/min and relative modes, capacitance to 40 mF, frequency to 30 MHz, duty cycle, temperature and 20 A current. CAT III 600 V.
Price and availability on request
Key features
- 3¾ digits, 3,999 counts
- True RMS
- Auto range
- Data hold, max/min and relative (REL) modes
- Non-contact voltage (NCV) detection
- Duty cycle
- Temperature with TP01 thermocouple
- Transistor hFE test
- Auto power off after 15 minutes with alarm buzzer
- Sampling rate approx. 3 times per second
- Backlight
Specifications
| Ranges (resolution) | 400 mV (0.1 mV), 4 V (1 mV), 40 V (10 mV), 400 V (100 mV), 1000 V (1 V) |
|---|---|
| Accuracy | 400 mV – 400 V: ±(0.5% of reading + 5 digits); 1000 V: ±(1.0% of reading + 5 digits) |
| Ranges (resolution) | 400 mV (0.1 mV), 4 V (1 mV), 40 V (10 mV), 400 V (100 mV), 750 V (1 V) |
|---|---|
| Accuracy | 400 mV: ±(1.5% + 10 digits); 4 V – 400 V: ±(0.8% + 10 digits); 750 V: ±(1.0% + 10 digits) |
| Ranges (resolution) | 400 µA (0.1 µA), 4000 µA (1 µA), 40 mA (10 µA), 400 mA (100 µA), 4 A (1 mA), 20 A (10 mA) |
|---|---|
| Accuracy | 20 A: ±(2.0% + 5 digits) |
| Ranges (resolution) | 400 µA (0.1 µA), 4000 µA (1 µA), 40 mA (10 µA), 400 mA (100 µA), 4 A (1 mA), 20 A (10 mA) |
|---|---|
| Accuracy | 400 µA – 4 A: ±(1.5% + 10 digits); 20 A: ±(2.0% + 10 digits) |
| Ranges (resolution) | 400 Ω (0.1 Ω), 4 kΩ (1 Ω), 40 kΩ (10 Ω), 400 kΩ (100 Ω), 4 MΩ (1 kΩ), 40 MΩ (10 kΩ) |
|---|---|
| Accuracy | 400 Ω: ±(0.8% + 5 digits); 4 kΩ – 4 MΩ: ±(0.8% + 2 digits); 40 MΩ: ±(1.2% + 5 digits) |
| Ranges (resolution) | 40 nF (10 pF), 400 nF (100 pF), 4 µF (1 nF), 40 µF (10 nF), 400 µF (100 nF), 4 mF (1 µF), 40 mF (10 µF) |
|---|---|
| Accuracy | 40 nF: ±(2.5% + 6 digits); 400 nF – 40 µF: ±(2.5% + 5 digits); 400 µF – 40 mF: ±(5.0% + 8 digits) |
| Ranges (resolution) | 10 Hz (0.001 Hz), 100 Hz (0.01 Hz), 1000 Hz (0.1 Hz), 10 kHz (1 Hz), 100 kHz (10 Hz), 1 MHz (100 Hz), 30 MHz (1 kHz) |
|---|---|
| Accuracy | 10 Hz: ±(2.5% + 6 digits); 100 Hz – 10 kHz: ±(2.5% + 5 digits); 100 kHz – 30 MHz: ±(5.0% + 8 digits) |
| Range (resolution) | −40 to 1000 °C (1 °C); 0 to 1832 °F (1 °F) |
|---|---|
| Accuracy | Below 400 °C: ±(0.8% + 4); 400 °C and above: ±(1.5% + 15); below 750 °F: ±(1.0% + 5); 750 °F and above: ±(1.5% + 15) |
| Range | 0 – 1000 (NPN or PNP) |
|---|---|
| Test conditions | Base current approx. 15 µA, VCE approx. 4.5 V |
| Safety category | CAT III 600 V |
|---|---|
| Power | 2 × 1.5 V AAA |
| Dimensions | H 185 × W 93 × D 35 mm |
| Weight | Approx. 290 g |
| Accessories | Test leads, sheath, TP01 thermocouple and manual |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.