HTC Instruments CM-2018 800 A AC/DC Digital Clamp Meter
- Brand
- HTC Instruments
- Model number
- CM-2018
- Category
- AC/DC Clamp Meters
True RMS AC/DC clamp meter to 800 A, 5,999 counts, with LPF (low-pass filter) and LoZ (low-impedance) voltage modes, NCV, capacitance, frequency and temperature. CAT II 600 V.
Price and availability on request
Key features
- 5,999 counts
- True RMS
- AC and DC current to 800 A
- LPF (low-pass filter) and LoZ (low-impedance) voltage measurement
- Duty cycle, relative (REL) and data hold
- Non-contact voltage (NCV) detection
- Jaw opening 28 mm
- Temperature with TP04 thermocouple
- Auto power off (APO)
- Torch and backlight
Specifications
| Ranges (resolution) | 60 A (10 mA), 600 A (100 mA), 800 A (1 A) |
|---|---|
| Accuracy | ±(1.5% of reading + 5 digits) |
| Ranges (resolution) | 60 A (10 mA), 600 A (100 mA), 800 A (1 A) |
|---|---|
| Accuracy | ±(1.5% of reading + 5 digits) |
| Ranges (resolution) | 600 mV (0.1 mV), 6 V (0.001 V), 60 V (0.01 V), 600 V (0.1 V) |
|---|---|
| Accuracy | 600 mV: ±(1.0% + 5 digits); 6 V – 600 V: ±(0.5% + 5 digits) |
| LoZ | 0 – 600 V (0.1 V), ±(2.0% + 10 digits) |
| Ranges (resolution) | 6 V (0.001 V), 60 V (0.01 V), 600 V (0.1 V) |
|---|---|
| Accuracy | ±(0.8% of reading + 5 digits) |
| LPF | 0 – 600 V (0.1 V), ±(4.0% + 5 digits) |
| LoZ | 0 – 600 V (0.1 V), ±(2.0% + 10 digits) |
| Ranges (resolution) | 600 Ω (0.1 Ω), 6 kΩ (1 Ω), 60 kΩ (10 Ω), 600 kΩ (100 Ω), 6 MΩ (1 kΩ), 60 MΩ (10 kΩ) |
|---|---|
| Accuracy | 600 Ω: ±(0.8% + 5 digits); 6 kΩ – 6 MΩ: ±(0.8% + 1 digit); 60 MΩ: ±(1.0% + 5 digits) |
| Ranges (resolution) | 6 nF (1 pF), 60 nF (10 pF), 600 nF (100 pF), 6 µF (1 nF), 60 µF (10 nF), 600 µF (100 nF), 6 mF (1 µF), 60 mF (10 µF) |
|---|---|
| Accuracy | 6 nF – 60 nF: ±(5.0% + 10 digits); 600 nF – 60 µF: ±(2.5% + 5 digits); 600 µF – 60 mF: ±(5.0% + 10 digits) |
| Range (resolution) | 10 Hz – 10 MHz (0.001 Hz – 1 kHz) |
|---|---|
| Accuracy | ±(0.5% of reading + 4 digits) |
| Range (resolution) | −40 to 1000 °C (1 °C); 0 to 1832 °F (1 °F) |
|---|---|
| Accuracy | Below 400 °C: ±(1.0% + 5 digits); 400 °C and above: ±(1.5% + 15 digits); below 750 °F: ±(1.0% + 5 digits); 750 °F and above: ±(1.5% + 15 digits) |
| Jaw opening | 28 mm |
|---|---|
| Safety category | CAT II 600 V |
| Power | 2 × 1.5 V AAA |
| Dimensions | H 185 × W 65 × D 32 mm |
| Weight | Approx. 200 g |
| Accessories | Test leads, manual, TP04 thermocouple, carrying bag and batteries |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.