HTC Instruments CM-2016 800 A AC/DC Digital Clamp Meter
- Brand
- HTC Instruments
- Model number
- CM-2016
- Category
- AC/DC Clamp Meters
True RMS AC/DC clamp meter to 800 A, 5,999 counts, with 28 mm jaw and jaw light, NCV, relative mode, duty cycle, capacitance, frequency to 10 MHz and temperature. CAT II 600 V.
Price and availability on request
Key features
- 5,999 counts
- True RMS
- AC and DC current to 800 A
- Jaw opening 28 mm, with jaw light
- Non-contact voltage (NCV) detection
- Frequency / duty cycle, relative (REL) and data hold
- Fully protected on all ranges
- LCD with 18 mm digits
- Compact and easy to carry
- Temperature with TP04 thermocouple
- Auto power off (APO)
- Torch and backlight
Specifications
| Ranges (resolution) | 60 A (0.01 A), 600 A (0.1 A), 800 A (1 A) |
|---|---|
| Accuracy | ±(1.5% of reading + 5 digits) |
| Ranges (resolution) | 60 A (0.01 A), 600 A (0.1 A), 800 A (1 A) |
|---|---|
| Accuracy | ±(1.5% of reading + 5 digits) |
| Ranges (resolution) | 600 mV (0.1 mV), 6 V (1 mV), 60 V (10 mV), 600 V (100 mV) |
|---|---|
| Accuracy | 600 mV: ±(1.0% + 5 digits); 6 V – 600 V: ±(0.5% + 5 digits) |
| Ranges (resolution) | 6 V (1 mV), 60 V (10 mV), 600 V (100 mV) |
|---|---|
| Accuracy | ±(0.8% of reading + 5 digits) |
| Ranges (resolution) | 600 Ω (0.1 Ω), 6 kΩ (1 Ω), 60 kΩ (10 Ω), 600 kΩ (100 Ω), 6 MΩ (1 kΩ), 60 MΩ (10 kΩ) |
|---|---|
| Accuracy | 600 Ω: ±(0.8% + 5 digits); 6 kΩ – 6 MΩ: ±(0.8% + 1 digit); 60 MΩ: ±(1.0% + 5 digits) |
| Ranges (resolution) | 6 nF (1 pF), 60 nF (10 pF), 600 nF (100 pF), 6 µF (1 nF), 60 µF (10 nF), 600 µF (100 nF), 6 mF (1 µF), 60 mF (10 µF) |
|---|---|
| Accuracy | 6 nF: ±(5.0% + 10 digits); 60 nF – 60 µF: ±(2.5% + 5 digits); 600 µF – 60 mF: ±(5.0% + 10 digits) |
| Ranges (resolution) | 10 Hz (0.01 Hz), 100 Hz (0.1 Hz), 1 kHz (1 Hz), 10 kHz (10 Hz), 100 kHz (100 Hz), 1 MHz (1 kHz), 10 MHz (10 kHz) |
|---|---|
| Accuracy | ±(0.5% of reading + 4 digits) |
| Range (resolution) | −40 to 1000 °C (1 °C); 0 to 1832 °F (1 °F) |
|---|---|
| Accuracy | Below 400 °C: ±(1.0% + 5 digits); 400 °C and above: ±(1.5% + 15 digits); below 750 °F: ±(1.0% + 5 digits); 750 °F and above: ±(1.5% + 15 digits) |
| Jaw opening | 28 mm |
|---|---|
| Safety category | CAT II 600 V |
| Power | 2 × 1.5 V AAA |
| Dimensions | H 185 × W 65 × D 32 mm |
| Weight | Approx. 200 g |
| Accessories | Test leads, manual, TP04 thermocouple, carrying bag and batteries |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.