HTC Instruments CM-2016 800 A AC/DC Digital Clamp Meter

Model number
CM-2016

True RMS AC/DC clamp meter to 800 A, 5,999 counts, with 28 mm jaw and jaw light, NCV, relative mode, duty cycle, capacitance, frequency to 10 MHz and temperature. CAT II 600 V.

Price and availability on request

Request a quote

Sent with the product details: HTC Instruments CM-2016 800 A AC/DC Digital Clamp Meter.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • 5,999 counts
  • True RMS
  • AC and DC current to 800 A
  • Jaw opening 28 mm, with jaw light
  • Non-contact voltage (NCV) detection
  • Frequency / duty cycle, relative (REL) and data hold
  • Fully protected on all ranges
  • LCD with 18 mm digits
  • Compact and easy to carry
  • Temperature with TP04 thermocouple
  • Auto power off (APO)
  • Torch and backlight

Specifications

DC current
Ranges (resolution)60 A (0.01 A), 600 A (0.1 A), 800 A (1 A)
Accuracy±⁠(1.5% of reading + 5 digits)
AC current
Ranges (resolution)60 A (0.01 A), 600 A (0.1 A), 800 A (1 A)
Accuracy±⁠(1.5% of reading + 5 digits)
DC voltage
Ranges (resolution)600 mV (0.1 mV), 6 V (1 mV), 60 V (10 mV), 600 V (100 mV)
Accuracy600 mV: ±⁠(1.0% + 5 digits); 6 V – 600 V: ±⁠(0.5% + 5 digits)
AC voltage
Ranges (resolution)6 V (1 mV), 60 V (10 mV), 600 V (100 mV)
Accuracy±⁠(0.8% of reading + 5 digits)
Resistance
Ranges (resolution)600 Ω (0.1 Ω), 6 kΩ (1 Ω), 60 kΩ (10 Ω), 600 kΩ (100 Ω), 6 MΩ (1 kΩ), 60 MΩ (10 kΩ)
Accuracy600 Ω: ±⁠(0.8% + 5 digits); 6 kΩ – 6 MΩ: ±⁠(0.8% + 1 digit); 60 MΩ: ±⁠(1.0% + 5 digits)
Capacitance
Ranges (resolution)6 nF (1 pF), 60 nF (10 pF), 600 nF (100 pF), 6 µF (1 nF), 60 µF (10 nF), 600 µF (100 nF), 6 mF (1 µF), 60 mF (10 µF)
Accuracy6 nF: ±⁠(5.0% + 10 digits); 60 nF – 60 µF: ±⁠(2.5% + 5 digits); 600 µF – 60 mF: ±⁠(5.0% + 10 digits)
Frequency
Ranges (resolution)10 Hz (0.01 Hz), 100 Hz (0.1 Hz), 1 kHz (1 Hz), 10 kHz (10 Hz), 100 kHz (100 Hz), 1 MHz (1 kHz), 10 MHz (10 kHz)
Accuracy±⁠(0.5% of reading + 4 digits)
Temperature
Range (resolution)−40 to 1000 °C (1 °C); 0 to 1832 °F (1 °F)
AccuracyBelow 400 °C: ±⁠(1.0% + 5 digits); 400 °C and above: ±⁠(1.5% + 15 digits); below 750 °F: ±⁠(1.0% + 5 digits); 750 °F and above: ±⁠(1.5% + 15 digits)
General
Jaw opening28 mm
Safety categoryCAT II 600 V
Power2 × 1.5 V AAA
DimensionsH 185 × W 65 × D 32 mm
WeightApprox. 200 g
AccessoriesTest leads, manual, TP04 thermocouple, carrying bag and batteries