Fluke i310s AC/DC Current Probe for Oscilloscopes

Brand
Fluke
Model number
i310s

Hall-effect AC/DC current probe for oscilloscopes: 30 A / 300 A AC rms, ±45 A / 450 A DC.

Price and availability on request

Request a quote

Sent with the product details: Fluke i310s AC/DC Current Probe for Oscilloscopes.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Current Ranges: 30 A and 300 A ACRMS or ±45 A and 450 A DC
  • Measuring Ranges: ±45 A and 450 A dc
  • Output Sensitivity: 10 mV/A (40 A) to 1 mV/A (400 A)
  • Resolution: ±50 mA (40 A) to ±100 mA (400 A)
  • Load Impedance: > 10 k Ohms and £ 100 pF
  • Frequency Range (small signal): DC to 20 kHz (- 3 dB)
  • Temperature Coefficient: ±0.1% of reading / °C
  • Power Supply: 9 V Alkaline

Specifications

Electrical Characteristics
Current ranges30 A and 300 A AC rms or ±45 A and 450 A DC
Measuring ranges±45 A and 450 A DC
AC rms or DC±45 A and 450 A
Inrush current600A AC rms MAX
Output sensitivity10 mV/A (30 A); 1 mV/A (300 A)
Accuracy (at +23°C), (30 A range)±1% of reading ±50 mA
Accuracy (at +23°C), (300 A range)±1% of reading ±300 mA
Bandwidth to meet accuracy specification1 kHz
Phase shift below 1 kHz< 2 degrees; < 2°
Resolution±50 mA (30 A); ±100 mA (300 A)
Load impedance> 10 k Ohms and ≤100 pF
Frequency range (small signal)DC to 20 kHz (-3 dB)
Temperature coefficient±0.1% of reading; °C
Power supply9 V Alkaline, MN1604/PP3
Battery life30 Hours, low battery indicator
Working voltage (see Safety Standards section)300 V AC rms or DC
General Characteristics
Maximum conductor size19 mm diameter
Output connectionSafety BNC connector; Supplied with safety 4mm adaptor
Output zeroManual adjust via thumbwheel
Cable length2 metres
Operating temperature range-10 to +50°C
Storage temperature range (with battery removed)-20 to +85°C
Operating humidity15% to 85% (non-condensing)
Weight250 g
SafetyIEC 61010-1, Pollution Degree 2; IEC 61010-2- 032: CAT III 300V; Use of the probe on uninsulated conductors is limited to 300 V ac rms or dc and frequencies below 1 kHz.

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.

About the i310s

The Fluke i310s is a Hall-effect probe for measuring DC and AC current with oscilloscopes and recording instruments, non-intrusively. Ranges are 30 A and 300 A AC rms, or ±45 A and 450 A DC.