Specifications
| Range | 2500 A AC |
|---|---|
| Resolution | 0.1A to 999.9, 1A from 1000 to 2500 |
| Accuracy | 3 % ± 5 digits |
| Crest factor (50 Hz/60 Hz) | 3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2 |
| Display | 3-1/2 digits, LCD w/backlight |
| Log rate/interval | 1 sec minimum/adjustable by PC or front panel |
| Battery type | 2 AA, NEDA 15 A, IEC LR6 |
| Battery life | 400 hours |
| Memory record | up to 65,000 readings |
| Unbound listen interval | 5 seconds |
| RF communications | 2.4 GHZ ISM Band |
| RF communication range | 20 Meters |
| Operating temperature | -10 °C to +50 °C |
| Storage temperature | -40 °C to +60 °C |
| Operating humidity | 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C |
| Safety compliance | EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III; 600 V Measurement Category (CAT) IV; EN/IEC 61010-2-030:2010; EN/IEC 610101-2-031:2002; EN/IEC 61010-2-032:2002 |
| Pollution degree | 2 |
| Temperature coefficient | Add 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C) |
| Safety rating | CAT IV 600 V, CAT III 1000 V |
| Certifications | CSA, FCC T68-FWCS IC:6627A-FWCS |
| Ingress Protection (IP) rating | IP42 |
| Size (HxWxD) | 16.5 cm x 6.35 cm x 3.56 cm |
| Weight | .22 kg (8 oz) |
| Jaw opening | 25.4 cm (10 in) coil |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.
About the CNX i3000
The CNX i3000 lets you fit a flexible iFlex probe around a conductor, close the panel and read the current from up to 20 m away on the CNX wireless multimeter. It measures true-rms AC current up to 2500 A, can be used in sets for three-phase work, and logs up to 65,000 time-stamped readings.