Fluke 87V MAX Rugged True-rms Multimeter, IP67
- Brand
- Fluke
- Model number
- 87V MAX
- Category
- Digital Multimeters
IP67 waterproof and dustproof true-rms multimeter, 4 m drop rated, with VFD filter and up to 800 h battery life.
Price and availability on request
Key features
- Withstands drops up to 4-meters (13 feet) with industrial strength casing and holster
- Waterproof, dustproof IP67 case for the most extreme work sites
- Premium TL175 TwistGuard test leads
- Double the battery life of the 87V (up to 800 hours); backlit keys for dark environments
Specifications
| DC Voltage, Range | 0.1 mV to 1000 V |
|---|---|
| DC Voltage, Accuracy | ±(0.05% + 1) |
| DC Voltage, Maximum resolution | 0.1 mV |
| AC Voltage, Range | 0.1 mV to 1000 V |
| AC Voltage, Accuracy | ±(0.7% + 4) true-rms |
| AC Voltage, AC bandwidth | 20 kHz with low pass filter; 3 dB @ 1 kHz |
| AC Voltage, Maximum resolution | 0.1 mV |
| DC Current, Range | 0.1 μA to 10 A (20 A for 30 seconds maximum) |
| DC Current, Amps accuracy | ±(0.2% + 2) |
| DC Current, Maximum resolution | 0.1 µA |
| AC Current, Range | 0.1 μA to 10 A (20 A for 30 seconds maximum) |
| AC Current, Amps accuracy | ±(1.0% + 2) true-rms |
| AC Current, Maximum resolution | 0.1 µA |
| Resistance, Range | 0.1 Ω to 50 MΩ |
| Resistance, Accuracy | ±(0.2% + 1) |
| Resistance, Maximum resolution | 0.1 Ω |
| Capacitance, Range | 0.01 nF to 9999 μF |
| Capacitance, Accuracy | ±(1% + 2) |
| Capacitance, Maximum resolution | 0.01 nF |
| Frequency, Range | 0.5 Hz to 199.99 kHz |
| Frequency, Accuracy | ±(0.005% + 1) |
| Frequency, Maximum resolution | 0.01 Hz |
| Duty cycle, Maximum duty cycle | 99.9% |
| Duty cycle, Accuracy | ±(0.2% per kHz + 0.1%) |
| Duty cycle, Maximum resolution | 0.1% |
| Temperature measurement range | –200.0 °C to 1090 °C; –328.0 °F to 1994.0 °F; excluding probe |
| 80 BK temperature probe | –40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater; –40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater |
| Conductance, Maximum conductance | 60.00 nS |
| Conductance, Accuracy | ±(1.0% + 10) |
| Conductance, Maximum resolution | 0.01 nS |
| Diode test, Range | 2 V |
| Diode test, Resolution | 0.001V |
| Diode test, Accuracy | ±(1% + 1) |
| Diagnostics and data storage, Peak Min/Max | 250 μS |
| Diagnostics and data storage, Min/Max/Avg | Yes |
| Diagnostics and data storage, Reading hold/Auto (Touch) Hold | Yes |
| Diagnostics and data storage, Relative reference | Yes |
| Display, Digital | 6000 counts updates 4/second; 19,999 counts in high–resolution mode |
| Display, Analog bar graph | 32 segments, updates 40/second |
| Low pass filter (VFD measurements) | Yes |
| Input Alert | Yes |
| Safety rating | IEC61010-1: Pollution Degree 2; IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V |
|---|
| IP rating | IEC 60529: IP67 |
|---|---|
| Power | Three AA batteries. 800 hours typical, without backlight |
| Size | 6.0 x 10.1 x 21.5 cm (with holster) |
| Weight | 698.5 g (with holster) |
| Warranty | Limited lifetime |
| Operating temperature | -15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C |
|---|---|
| Storage temperature | -40 °C to + 60 °C |
| Humidity (without condensation) | 0% – 90% (0 °C – 35 °C); 0% – 70% (35 °C – 55 °C) |
| Operating altitude | 2000 m |
| Contents | TL175 TwistGuard test leads; AC175 Alligator clips; 80BK-A temperature probe; Removable holster with test lead storage; Three AA batteries (installed) |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.
About the 87V MAX
The Fluke 87V MAX keeps the functions of the 87V in a tougher package: an IP67 waterproof and dustproof case with holster, rated for a 4 m drop, backlit keys and up to 800 hours of battery life. It includes the low-pass filter for accurate measurements on VFDs and is supplied with TL175 TwistGuard test leads.