Fluke 87V MAX Rugged True-rms Multimeter, IP67

Brand
Fluke
Model number
87V MAX

IP67 waterproof and dustproof true-rms multimeter, 4 m drop rated, with VFD filter and up to 800 h battery life.

Price and availability on request

Request a quote

Sent with the product details: Fluke 87V MAX Rugged True-rms Multimeter, IP67.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Withstands drops up to 4-meters (13 feet) with industrial strength casing and holster
  • Waterproof, dustproof IP67 case for the most extreme work sites
  • Premium TL175 TwistGuard test leads
  • Double the battery life of the 87V (up to 800 hours); backlit keys for dark environments

Specifications

Electrical Specifications
DC Voltage, Range0.1 mV to 1000 V
DC Voltage, Accuracy±⁠(0.05% + 1)
DC Voltage, Maximum resolution0.1 mV
AC Voltage, Range0.1 mV to 1000 V
AC Voltage, Accuracy±⁠(0.7% + 4) true-rms
AC Voltage, AC bandwidth20 kHz with low pass filter; 3 dB @ 1 kHz
AC Voltage, Maximum resolution0.1 mV
DC Current, Range0.1 μA to 10 A (20 A for 30 seconds maximum)
DC Current, Amps accuracy±⁠(0.2% + 2)
DC Current, Maximum resolution0.1 µA
AC Current, Range0.1 μA to 10 A (20 A for 30 seconds maximum)
AC Current, Amps accuracy±⁠(1.0% + 2) true-rms
AC Current, Maximum resolution0.1 µA
Resistance, Range0.1 Ω to 50 MΩ
Resistance, Accuracy±⁠(0.2% + 1)
Resistance, Maximum resolution0.1 Ω
Capacitance, Range0.01 nF to 9999 μF
Capacitance, Accuracy±⁠(1% + 2)
Capacitance, Maximum resolution0.01 nF
Frequency, Range0.5 Hz to 199.99 kHz
Frequency, Accuracy±⁠(0.005% + 1)
Frequency, Maximum resolution0.01 Hz
Duty cycle, Maximum duty cycle99.9%
Duty cycle, Accuracy±⁠(0.2% per kHz + 0.1%)
Duty cycle, Maximum resolution0.1%
Temperature measurement range–200.0 °C to 1090 °C; –328.0 °F to 1994.0 °F; excluding probe
80 BK temperature probe–40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater; –40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater
Conductance, Maximum conductance60.00 nS
Conductance, Accuracy±⁠(1.0% + 10)
Conductance, Maximum resolution0.01 nS
Diode test, Range2 V
Diode test, Resolution0.001V
Diode test, Accuracy±⁠(1% + 1)
Diagnostics and data storage, Peak Min/Max250 μS
Diagnostics and data storage, Min/Max/AvgYes
Diagnostics and data storage, Reading hold/Auto (Touch) HoldYes
Diagnostics and data storage, Relative referenceYes
Display, Digital6000 counts updates 4/second; 19,999 counts in high–resolution mode
Display, Analog bar graph32 segments, updates 40/second
Low pass filter (VFD measurements)Yes
Input AlertYes
Safety Specifications
Safety ratingIEC61010-1: Pollution Degree 2; IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V
Mechanical and General Specifications
IP ratingIEC 60529: IP67
PowerThree AA batteries. 800 hours typical, without backlight
Size6.0 x 10.1 x 21.5 cm (with holster)
Weight698.5 g (with holster)
WarrantyLimited lifetime
Environmental Specifications
Operating temperature-15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C
Storage temperature-40 °C to + 60 °C
Humidity (without condensation)0% – 90% (0 °C – 35 °C); 0% – 70% (35 °C – 55 °C)
Operating altitude2000 m
Supplied with
ContentsTL175 TwistGuard test leads; AC175 Alligator clips; 80BK-A temperature probe; Removable holster with test lead storage; Three AA batteries (installed)

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.

About the 87V MAX

The Fluke 87V MAX keeps the functions of the 87V in a tougher package: an IP67 waterproof and dustproof case with holster, rated for a 4 m drop, backlit keys and up to 800 hours of battery life. It includes the low-pass filter for accurate measurements on VFDs and is supplied with TL175 TwistGuard test leads.