Fluke 87V True-rms Industrial Multimeter

Brand
Fluke
Model number
87V

True-rms industrial multimeter with low-pass filter for VFDs and 250 µs Peak Capture; temperature probe included.

Price and availability on request

Request a quote

Sent with the product details: Fluke 87V True-rms Industrial Multimeter.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Identify complex signal problems fast
  • Supports accurate measurements on VFDs using a low-pass filter
  • Captures intermittents as fast as 250 µS with Peak Capture

Specifications

Specifications
Voltage DC, Maximum voltage1000 V
Voltage DC, Accuracy±⁠(0.05% + 1)
Voltage DC, Maximum resolution10 µV
Voltage AC, Maximum voltage1000 V
Voltage AC, Accuracy±⁠(0.7% + 2) True RMS
Voltage AC, AC bandwidth20 kHz with low pass filter; 3 dB @ 1 kHz
Voltage AC, Maximum resolution0.1 mV
Current DC, Maximum amps10 A (20 A for 30 seconds maximum)
Current DC, Amps accuracy±⁠(0.2% + 2)
Current DC, Maximum resolution0.01 µA
Current AC, Maximum amps10 A (20 A for 30 seconds maximum)
Current AC, Amps accuracy±⁠(1.0% + 2) True RMS
Current AC, Maximum resolution0.1 µA
Resistance, Maximum resistance50 MΩ
Resistance, Accuracy±⁠(0.2% + 1)
Resistance, Maximum resolution0.1 Ω
Capacitance, Maximum capacitance9,999 µF
Capacitance, accuracy±⁠(1% + 2)
Capacitance, Maximum resolution0.01 nF
Frequency, Maximum frequency200 kHz
Frequency, Accuracy±⁠(0.005% + 1)
Frequency, Maximum resolution0.01 Hz
Duty cycle, Maximum duty cycle99.9%
Duty cycle, Accuracy±⁠(0.2% per kHz + 0.1%)
Duty cycle, Maximum resolution0.1%
Temperature measurement-200.0 °C to 1090 °C; -328.0 °F to 1994.0 °F; excluding probe
80 BK temperature probe-40.0 °C to 260 °C; -40.0 °F to 500 °F, 2.2 °C or 2% whichever is greater
Conductance, Maximum conductance60.00 nS
Conductance, Accuracy±⁠(1.0% + 10)
Conductance, Maximum resolution0.01 nS
Diode, Range3 V
Diode, Resolution1 mV
Diode, Accuracy±⁠(2% + 1)
Duty cycle range, AccuracyWithin ±⁠(0.2% per kHz + 0.1%)
Environmental Specifications
Operating temperature–20 °C to + 55 °C
Storage temperature–40 °C to + 60 °C
Humidity (without condensation)0% – 90% (0 °C – 35 °C); 0% – 70% (35 °C – 55 °C)
Operating Altitude2000 m
Safety Specifications
Overvoltage categoryEN 61010–1 to 1000 V CAT III, 600V CAT IV
Mechanical and General Specifications
Size201 x 98 x 52 mm (with holster)
Weight355 g; 624 g – with holster
Display, Digital6000 counts updates 4/sec.; 19,999 counts in high–resolution mode
Display, Analog32 segments, updates 40/sec
Display, Frequency19,999 counts, updates 3/sec at > 10 Hz
WarrantyLifetime
Battery Life, Alkaline~400 hours typical, without backlight
Shock1 Meter drop per IEC 61010–1:2001
VibrationPer MIL–PRF–28800 for a Class 2 instrument
Supplied with
ContentsTL75 Test Leads (TL175 EUR); AC175 Alligator Clips; Holster; 9V Battery (Installed); 80BK Temperature Probe

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.

About the 87V

The Fluke 87V is an industrial meter for motor drives, plant automation, power distribution and electromechanical equipment. A low-pass filter gives accurate readings on variable frequency drives, Peak Capture catches events as short as 250 µs, and an 80BK probe is supplied for temperature. It has an analogue bar graph, two-level backlight and Touch Hold.