Fluke 283 FC True-rms Digital Multimeter, CAT III 1500 V

Brand
Fluke
Model number
283 FC

True-rms CAT III 1500 V / CAT IV 1000 V multimeter for solar PV, wind, rail and data centres; TL175-HV leads included.

Price and availability on request

Request a quote

Sent with the product details: Fluke 283 FC True-rms Digital Multimeter, CAT III 1500 V.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Measure safely with CAT III 1500 V/CAT IV 1000 V safety rated multimeter
  • Includes TL175-HV CAT III 1500 V/CAT IV 1000 V safety rated premium test leads
  • User-defined limit gauge for quick go/no-go decisions
  • Unique multimeter readiness self-check
  • Visual and audio polarity indicators with on/off function wiring issues

Specifications

Specifications
DC voltsRange 6.000 V; Resolution 0.001 V; Accuracy 0.09 % + 3; Range 60.00 V; Resolution 0.01 V; Accuracy 0.09 % + 3; Range 600.0 V; Resolution 0.1 V; Accuracy 0.09 % + 3; Range 1500 V; Resolution 1 V; Accuracy 0.15 % + 2
AC mVRange 600.0 mV; Resolution 0.1 mV; Accuracy 1.0% + 3 (45 Hz ~ 500 Hz); 2.0% + 3 (500 Hz ~ 1000 Hz)
DC mVRange 600.0 mV; Resolution 0.1 mV; Accuracy 0.09 % + 2
ContinuityRange 600 Ω; Resolution 1 Ω
CapacitanceRange 1000 nF; Resolution 1 nF; Accuracy 1.2 % + 2; Range 10.00 μF; Resolution 0.01 μF; Accuracy 1.2 % + 2; Range 100.0 μF; Resolution 0.1 μF; Accuracy 1.2 % + 2; Range 9999 μF; Resolution 1 μF; Accuracy 10 % typical
FrequencyRange 99.99 Hz; Resolution 0.01 Hz; Accuracy 0.1 % + 2; Range 999.9 Hz; Resolution 0.1 Hz; Accuracy 0.1 % + 2; Range 9.999 kHz; Resolution 0.001 kHz; Accuracy 0.1 % + 2; Range 99.99 kHz; Resolution 0.01 kHz; Accuracy 0.1 % + 2
AC VA (45 Hz ~ 500 Hz)Range 360.0 VA; Resolution 0.1 VA; Accuracy 2 % + 1.0 VA; Range 3.600 kVA; Resolution 0.001 kVA; Accuracy 2 % + 0.01 kVA; Range 36.00 kVA; Resolution 0.01 kVA; Accuracy 2 % + 0.1 kVA; Range 60.00 kVA; Resolution 0.01 kVA; Accuracy 2 % + 0.15 kVA
DC VARange 360.0 VA; Resolution 0.1 VA; Accuracy 2 % + 1.0 VA; Range 3.600 kVA; Resolution 0.001 kVA; Accuracy 2 % + 0.01 kVA; Range 36.00 kVA; Resolution 0.01 kVA; Accuracy 2 % + 0.1 kVA; Range 90.00 kVA; Resolution 0.01 kVA; Accuracy 2 % + 0.25 kVA
Environmental specifications
Operating temperature-10 °C to 60 °C
Storage temperature-30 °C to +70 °C
Humidity (without condensation)0 % to 90 %, 10 °C to 30 °C; 0 % to 75 %, 30 °C to 40 °C; 0 % to 45 %, 40 °C to 60 °C
Warranty and Protection
Overvoltage categoryCAT III 1500 V, CAT IV 1000 V
Drop test2 meter (6.5 ft) drop test
Ingress protectionIP52
WarrantyLimited lifetime
Mechanical and general specifications
Counts6000
Size22.5 cm x 10.5 cm x 5.7 cm (8.8 in x 4.1 in x 2.2 in)
Weight0.7 kg (1.5 lb)
Battery life> 150 hours typical, without backlight (Alkaline, 3 AA); > 100 hours typical when connected to wireless current clamp (Alkaline, 3 AA)
Supplied with
Contents283 FC TRMS Wireless Digital Multimeter; TL175-HV TwistGuard Silicone test leads; Premium carrying case; Magnetic hanging strap; Limited Lifetime Warranty

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.

About the 283 FC

The Fluke 283 FC is designed for DC systems up to 1500 V, such as utility-scale solar PV, wind, electric railways and data centres. It is rated CAT III 1500 V / CAT IV 1000 V, comes with matching TL175-HV silicone test leads, and adds a user-set limit gauge for go/no-go checks, a readiness self-check and polarity indicators.