Fluke 17B+ Digital Multimeter with Temperature

Brand
Fluke
Model number
17B+

Rugged digital multimeter with frequency and temperature (type K thermocouple included): 1000 V, 10 A, CAT III 600 V.

Price and availability on request

Request a quote

Sent with the product details: Fluke 17B+ Digital Multimeter with Temperature.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • 600 V Cat III safety rating
  • AC/DC voltage measurement up to 1000V
  • AC/DC current measurement up to 10A
  • Measures voltage, resistance, continuity, capacitance
  • Frequency and temperature measurement
  • Large easy-to-read display with bright white backlight

Specifications

Specifications
AC volts (40 Hz to 500Hz)Range 4.000 V; 40.00 V; 400.0 V; 1000 V; Resolution 0.001 V; 0.01 V; 0.1 V; 1 V; Accuracy 1.0% + 3
AC millivoltsRange 400.0 mV; Resolution 0.1 mV; Accuracy 3.0% + 3; Overload protection 400 mV; Input impedance (Nominal) >1MΩ, <100 pF; Common mode rejection ratio >80 dB at 50 Hz or 60 Hz
DC millivoltsRange 400.0 mV; Resolution 0.1 mV; Accuracy 1.0% + 10; Overload protection 400 mV; Input impedance (Nominal) >1MΩ, <100 pF; Common mode rejection ratio >80 dB at 50 Hz or 60 Hz
Diode testRange 2.000 V; Resolution 0.001 V; Accuracy 10%
Resistance (Ohms)Range 400.0 Ω; 4.000 kΩ; 40.00 kΩ; 400.0 kΩ; 4.000 MΩ; 40.00 MΩ; Resolution 0.1 Ω; 0.001 kΩ; 0.01 kΩ; 0.1 kΩ; 0.001 MΩ; 0.01 MΩ; Accuracy 0.5% + 3 / 0.5% + 2 / 0.5% + 2 / 0.5% + 2 / 0.5% + 2 / 1.5% + 3
CapacitanceRange 40.00 nF; 400.0 nF; 4.000 μF; 40.00 μF; 400.0 μF; 1000 μF; Resolution 0.01 nF; 0.1 nF; 0.001 μF; 0.01 μF; 0.1 μF; 1 μF; Accuracy 2% + 5 / 2% + 5 / 5% + 5 / 5% + 5 / 5% + 5 / 5% + 5
Frequency1 Hz (10 Hz – 100 kHz)Range 50.00 Hz; 500.0 Hz; 5.000 kHz; 50.00 kHz; 100.0 kHz; Resolution 0.01 Hz; 0.1 Hz; 0.001 kHz; 0.01 kHz; 0.1 kHz; Accuracy 0.1% + 3
Duty CycleRange 1% to 99%; Resolution 0.1%; Accuracy 1% typical 4
AC current μA (40 Hz to 400 Hz)Range 400.0 μA; 4000 μA; Resolution 0.1 μA; 1 μA; Accuracy 1.5% + 3
AC current mA (40 Hz to 400 Hz)Range 40.00 mA; 400.0 mA; Resolution 0.01 mA; 0.1 mA; Accuracy 1.5% + 3
AC current A (40 Hz to 400 Hz)Range 4.000 A; 10.00 A; Resolution 0.001 A; 0.01 A; Accuracy 1.5% + 3
DC current μARange 400.0 μA; 4000 μA; Resolution 0.1 μA; 1 μA; Accuracy 1.5% + 3
DC current mARange 40.00 mA; 400.0 mA; Resolution 0.01 mA; 0.1 mA; Accuracy 1.5% + 3
DC current ARange 4.000 A; 10.00 A; Resolution 0.001 A; 0.01 A; Accuracy 1.5% + 3
TemperatureRange 50 °C- 400 °C; 0 °C- 50 °C; -55 °C- 0 °C; Resolution 0.1C; Accuracy 2% ±1 °C; ±2 °C; 9% ±2 °C
BacklightYes
AC voltsOverload protection 1000 V; Input impedance (Nominal) >10 MΩ <100 pF; Common mode rejection ratio >60 dB at dc, 50 Hz or 60 Hz
General specifications
Maximum voltage between any terminal and earth ground1000 V
Display (LCD)4000 counts, updates 3/sec
Battery type2 AA, NEDA 15A, IEC LR6
Battery life500 hours minimum
Temperature
Operating0 °C to 40 °C
Storage-30 °C to 60 °C
Relative humidity
Operating humidityNon-condensing (<10°C); ≤90% RH at 10 °C to 30 °C; ≤75% RH at 30 °C to 40 °C; 40 MΩ range; ≤80% RH at 10 °C to 30 °C; ≤70% RH at 30 °C to 40 °C
Altitude
Operating2000 m
Storage12,000 m
Temperature coefficient0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs440 mA, 1000 V Fast Fuse, Fluke specified part only.; 11A, 1000V Fast Fuse, Fluke specified part only.
Size (H x W x L)183 x 91 x 49.5 mm
Weight455 g
IP ratingIP 40
SafetyIEC 61010-1, IEC61010-2-030 CAT III 600 V, Pollution Degree 2

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.

About the 17B+

The Fluke 17B+ adds frequency and temperature measurement to the 15B+ feature set, and comes with a type K thermocouple. It measures AC and DC voltage up to 1000 V and current up to 10 A, plus resistance, continuity and capacitance, and is rated CAT III 600 V.