Fluke 17B MAX KIT Digital Multimeter Kit with TL75 and TL31 Test Leads

Brand
Fluke
Model number
17B MAX KIT

17B MAX multimeter kit with TL75 and TL31 test leads and a type K thermocouple; frequency and temperature, CAT III 600 V.

Price and availability on request

Request a quote

Sent with the product details: Fluke 17B MAX KIT Digital Multimeter Kit with TL75 and TL31 Test Leads.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Audible and visual alarm for incorrect connections
  • Test leads with fines tips for circuit board testing
  • Simple interface to wake meter from sleep mode by activating any buttons
  • Voltage: 6000-count reading
  • Capacitance range: 2000uF
  • Safety rating: CATIII 600V
  • Frequency and temperature measurement

Specifications

Specifications
AC Volts (40 Hz to 500 Hz)Range 6.000 V; 60.00 V; 600.0 V; 1000 V; Resolution 0.001 V; 0.01 V; 0.1 V; 1 V; 1.0 % + 3
AC MillivoltsRange 600.0 mV; Resolution 0.1 mV; 3.0 % + 3
DC VoltsRange 6.000 V; 60.00 V; 600.0 V; 1000 V; Resolution 0.001 V; 0.01 V; 0.1 V; 1 V; 0.5 % + 3
DC MillivoltsRange 600.0 mV; Resolution 0.1 mV; 1.0 % + 10
AC Current μA (40 Hz to 400 Hz)Range 400.0 μA; 4000 μA; Resolution 0.1 μA; 1 μA; 1.5 % + 3
AC Current mA (40 Hz to 400 Hz)Range 40.00 mA; 400.0 mA; Resolution 0.01 mA; 0.1 mA; 1.5 % + 3
AC Current A (40 Hz to 400 Hz)Range 4.000 A; 10.00 A; Resolution 0.001 A; 0.01 A; 1.5 % + 3
DC Current μARange 400.0 μA; 4000 μA; Resolution 0.1 μA; 1 μA; 1.5 % + 3
DC Current mARange 40.00 mA; 400.0 mA; Resolution 0.01 mA; 0.1 mA; 1.5 % + 3
DC Current ARange 4.000 A; 10.00 A; Resolution 0.001 A; 0.01 A; 1.5 % + 3
Diode TestRange 2.000 V; Resolution 0.001 V; 10%
TemperatureRange 50.0 °C to 400.0 °C; 0 °C to 50.0 °C; -55.0 °C to 0 °C; Resolution 0.1 °C; 2 %+1 °C; 2 °C; 9 %+2 °C
Resistance (Ohms)Range 400.0 Ω; 4.000 kΩ; 40.00 kΩ; 400.0 kΩ; 4.000 MΩ; 40.00 MΩ; Resolution 0.1 Ω; 0.001 kΩ; 0.01 kΩ; 0.1 kΩ; 0.001 MΩ; 0.01 MΩ; 0.5 % + 3 / 0.5 % + 2 / 0.5 % + 2 / 0.5 % + 2 / 0.5 % + 2 / 1.5 % + 3
CapacitanceRange 40.00 nF; 400.0 nF; 4.000 μF; 40.00 μF; 400.0 μF; 2000 μF; Resolution 0.01 nF; 0.1 nF; 0.001 μF; 0.01 μF; 0.1 μF; 1 μF; 2 % + 5 / 2 % + 5 / 5 % + 5 / 5 % + 5 / 5 % + 5 / 5 % + 5
Frequency (10 Hz to 100 kHz)Range 50.00 Hz; 500.0 Hz; 5.000 kHz; 50.00 kHz; 100.0 kHz; Resolution 0.01 Hz; 0.1 Hz; 0.001 kHz; 0.01 kHz; 0.1 kHz; 0.1 % + 3
Duty CycleRange 1% to 99%; Resolution 0.10%; 1 % typical
Continuity Threshold70Ω
BacklightYes
Input Characteristics
AC VoltsOverload Protection 1000 V; Input Impedance (Nominal) >10 MΩ, <100 pF; Common Mode Rejection Ratio >60 dB at 50 Hz or 60 Hz
AC MillivoltsOverload Protection 1000 V; Input Impedance (Nominal) >1 MΩ, <100 pF; Common Mode Rejection Ratio >80 dB at 50 Hz or 60 Hz
DC VoltsOverload Protection 1000 V; Input Impedance (Nominal) >10 MΩ, <100 pF; Common Mode Rejection Ratio >100 dB at 50 Hz or 60 Hz; Normal Mode Rejection Ratio >60 dB at 50 Hz or 60 Hz
DC MillivoltsOverload Protection 1000 V; Input Impedance (Nominal) >1 MΩ, <100 pF; Common Mode Rejection Ratio >80 dB at 50 Hz or 60 Hz
General Specifications
Maximum voltage between any Terminal and Earth Ground600 V
Maximum differential voltage between V and COM terminals1000V
Display (LCD)6000 counts, updates 3/sec
Battery Type2 AA, IEC LR6
Battery life500 hours minimum
TemperatureOperating 0 °C to 40 °C; Storage -30 °C to 60 °C
Relative HumidityOperating Humidity Non-condensing (<10 °C); ≤90 % RH at 10 °C to 30 °C; ≤75 % RH at 30 °C to 40 °C
Operating Humidity, 40 MΩ range≤80 % RH at 10 °C to 30 °C; ≤70 % RH at 30 °C to 40 °C
AltitudeOperating 2000 m; Storage 12000 m
Temperature Coefficient0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs440 mA, 1000 V, fast-blow, use only Fluke; specified parts. 11 A, 1000 V, fast-blow, use only Fluke specified parts
Size (HxWxL)183 mm x 91 mm x 49.5 mm
Weight455 g
Ingress ProtectionIP40
SafetyIEC 61010-1, IEC61010-2-030: CAT III; 600 V, Pollution Degree 2
Supplied with
ContentsTL75 test leads with 2 protective caps; TL31 extra-slim test leads with 2 protective caps; Type K thermocouple; 2 AA batteries

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.

About the 17B MAX KIT

The 17B MAX kit pairs the Fluke 17B MAX, with its input alert alarm, frequency and temperature functions, with both TL75 general-purpose and TL31 extra-slim test leads and a type K thermocouple. The meter also measures AC and DC voltage and current, resistance and capacitance up to 2000 µF.