Fluke 17B MAX-02 Digital Multimeter with TL31 Extra-Slim Test Leads

Brand
Fluke
Model number
17B MAX-02

6000-count multimeter with frequency, temperature and input alert alarm, supplied with TL31 extra-slim leads and a type K thermocouple.

Price and availability on request

Request a quote

Sent with the product details: Fluke 17B MAX-02 Digital Multimeter with TL31 Extra-Slim Test Leads.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Audible and visual alarm for incorrect connections
  • Test leads with fines tips for circuit board testing
  • Simple interface to wake meter from sleep mode by activating any buttons
  • Voltage: 6000-count reading
  • Capacitance range: 2000uF
  • Safety rating: CATIII 600V
  • Frequency and temperature measurement

Specifications

Specifications
AC Volts (40 Hz to 500 Hz)Range 6.000 V; 60.00 V; 600.0 V; 1000 V; Resolution 0.001 V; 0.01 V; 0.1 V; 1 V; 1.0 % + 3
AC MillivoltsRange 600.0 mV; Resolution 0.1 mV; 3.0 % + 3
DC VoltsRange 6.000 V; 60.00 V; 600.0 V; 1000 V; Resolution 0.001 V; 0.01 V; 0.1 V; 1 V; 0.5 % + 3
DC MillivoltsRange 600.0 mV; Resolution 0.1 mV; 1.0 % + 10
AC Current μA (40 Hz to 400 Hz)Range 400.0 μA; 4000 μA; Resolution 0.1 μA; 1 μA; 1.5 % + 3
AC Current mA (40 Hz to 400 Hz)Range 40.00 mA; 400.0 mA; Resolution 0.01 mA; 0.1 mA; 1.5 % + 3
AC Current A (40 Hz to 400 Hz)Range 4.000 A; 10.00 A; Resolution 0.001 A; 0.01 A; 1.5 % + 3
DC Current μARange 400.0 μA; 4000 μA; Resolution 0.1 μA; 1 μA; 1.5 % + 3
DC Current mARange 40.00 mA; 400.0 mA; Resolution 0.01 mA; 0.1 mA; 1.5 % + 3
DC Current ARange 4.000 A; 10.00 A; Resolution 0.001 A; 0.01 A; 1.5 % + 3
Diode TestRange 2.000 V; Resolution 0.001 V; 10%
TemperatureRange 50.0 °C to 400.0 °C; 0 °C to 50.0 °C; -55.0 °C to 0 °C; Resolution 0.1 °C; 2 %+1 °C; 2 °C; 9 %+2 °C
Resistance (Ohms)Range 400.0 Ω; 4.000 kΩ; 40.00 kΩ; 400.0 kΩ; 4.000 MΩ; 40.00 MΩ; Resolution 0.1 Ω; 0.001 kΩ; 0.01 kΩ; 0.1 kΩ; 0.001 MΩ; 0.01 MΩ; 0.5 % + 3 / 0.5 % + 2 / 0.5 % + 2 / 0.5 % + 2 / 0.5 % + 2 / 1.5 % + 3
CapacitanceRange 40.00 nF; 400.0 nF; 4.000 μF; 40.00 μF; 400.0 μF; 2000 μF; Resolution 0.01 nF; 0.1 nF; 0.001 μF; 0.01 μF; 0.1 μF; 1 μF; 2 % + 5 / 2 % + 5 / 5 % + 5 / 5 % + 5 / 5 % + 5 / 5 % + 5
Frequency (10 Hz to 100 kHz)Range 50.00 Hz; 500.0 Hz; 5.000 kHz; 50.00 kHz; 100.0 kHz; Resolution 0.01 Hz; 0.1 Hz; 0.001 kHz; 0.01 kHz; 0.1 kHz; 0.1 % + 3
Duty CycleRange 1% to 99%; Resolution 0.10%; 1 % typical
Continuity Threshold70Ω
BacklightYes
Input Characteristics
AC VoltsOverload Protection 1000 V; Input Impedance (Nominal) >10 MΩ, <100 pF; Common Mode Rejection Ratio >60 dB at 50 Hz or 60 Hz
AC MillivoltsOverload Protection 1000 V; Input Impedance (Nominal) >1 MΩ, <100 pF; Common Mode Rejection Ratio >80 dB at 50 Hz or 60 Hz
DC VoltsOverload Protection 1000 V; Input Impedance (Nominal) >10 MΩ, <100 pF; Common Mode Rejection Ratio >100 dB at 50 Hz or 60 Hz; Normal Mode Rejection Ratio >60 dB at 50 Hz or 60 Hz
DC MillivoltsOverload Protection 1000 V; Input Impedance (Nominal) >1 MΩ, <100 pF; Common Mode Rejection Ratio >80 dB at 50 Hz or 60 Hz
General Specifications
Maximum voltage between any Terminal and Earth Ground600 V
Maximum differential voltage between V and COM terminals1000V
Display (LCD)6000 counts, updates 3/sec
Battery Type2 AA, IEC LR6
Battery life500 hours minimum
TemperatureOperating 0 °C to 40 °C; Storage -30 °C to 60 °C
Relative HumidityOperating Humidity Non-condensing (<10 °C); ≤90 % RH at 10 °C to 30 °C; ≤75 % RH at 30 °C to 40 °C
Operating Humidity, 40 MΩ range≤80 % RH at 10 °C to 30 °C; ≤70 % RH at 30 °C to 40 °C
AltitudeOperating 2000 m; Storage 12000 m
Temperature Coefficient0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs440 mA, 1000 V, fast-blow, use only Fluke; specified parts. 11 A, 1000 V, fast-blow, use only Fluke specified parts
Size (HxWxL)183 mm x 91 mm x 49.5 mm
Weight455 g
Ingress ProtectionIP40
SafetyIEC 61010-1, IEC61010-2-030: CAT III; 600 V, Pollution Degree 2
Supplied with
ContentsTL31 extra-slim test leads with 2 protective caps; Type K thermocouple; 2 AA batteries

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.

About the 17B MAX-02

The Fluke 17B MAX builds on the 17B+ with an alarm for wrong lead connections and wake-up from sleep by pressing any button. Besides AC and DC voltage and current, resistance and capacitance up to 2000 µF, it measures frequency and temperature. This version (-02) comes with TL31 extra-slim test leads and a type K thermocouple.