Fluke 116 True-rms HVAC Multimeter
- Brand
- Fluke
- Model number
- 116
- Category
- Digital Multimeters
True-rms HVAC multimeter with built-in thermometer (-40 to 400 °C) and microamps for flame sensors.
Price and availability on request
Key features
- Digital multimeter designed specifically for HVAC professionals
- Includes built-in thermometer to measure temperature from -40°C to 400°C (-40°F to 752°F)
- Provides microamps to test flame sensors
- Features low input impedance to helps prevent false readings due to ghost voltage
- Presents a large white LED backlight for working in poorly lit areas
Specifications
| Maximum voltage between any terminal and earth ground | 600 V |
|---|---|
| Safety | IEC 61010-1: Pollution Degree 2; IEC 61010-2-033: CAT III 600V |
| Display | Digital: 6,000 counts, updates 4 per second |
| Bar graph | 33 segments, updates 32 per second |
| Operating temperature | -10°C to + 50°C |
| Storage temperature | -40°C to + 60°C |
| Battery type | 9 volt Alkaline, IEC 6LR61 |
| Battery life | 400 hours typical, without backlight |
| DC millivolts, Range/resolution | 600.0 mV; 0.1 mV |
|---|---|
| DC millivolts, Accuracy | ±([% of reading] + [counts]): 0.5% + 2 |
| DC volts, Range/resolution | 6.000 V; 0.001 V; 60.00 V; 0.01 V; 600.00 V; 0.1 V |
| DC volts, Accuracy | ±([% of reading] + [counts]): 0.5% + 2 |
| Auto volts, Range/resolution | 600.0 V; 0.1 V |
| Auto volts, Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz); 4.0% + 3 (500 Hz to 1 kHz) |
| AC millivolts1 True RMS, Range/resolution | 600.0 mV; 0.1 mV |
| AC millivolts1 True RMS, Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz); 2.0% + 3 (500 Hz to 1 kHz) |
| AC volts1 True RMS, Range/resolution | 6.000 V; 0.001 V; 60.00 V; 0.01 V; 600.0 V; 0.1 V |
| AC volts1 True RMS, Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz); 2.0% + 3 (500 Hz to 1 kHz) |
| Continuity, Range/resolution | 600 Ω; 1 Ω |
| Continuity, Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of; 500 μs or longer. |
| Ohms, Range/resolution | 600.0 Ω; 0.1 Ω; 6.000 kΩ; 0.001 kΩ; 60.00 kΩ; 0.01 kΩ; 600.0 kΩ; 0.1 kΩ; 6.000 MΩ; 0.001 MΩ |
| Ohms, Accuracy | 0.9% + 1; 5% + 2 |
| Ohms, Range/Resolution | 40.00 MΩ; 0.01 MΩ |
| Diode Test, Range/resolution | 2.00 V; 0.001 V |
| Diode Test, Accuracy | 0.9% + 2 |
| Capacitance, Range/resolution | 1000 nF; 1 nF; 10.00 μF; 0.01 μF; 100.0 μF; 0.1 μF; 9999 μF; 1 μF; 100 μF to 1000 μF; > 1000 μF |
| Capacitance, Accuracy | 1.9% + 2; 5% + 20% |
| Lo-Z Capacitance, Range | 1 nF to 500 μF |
| Lo-Z Capacitance, Accuracy | 10% + 2 typical |
| Temperature² (Type-K thermocouple), Range/resolution | -40°C to 400°C; 0.1°C; -40°F to 752°F; 0.2°F |
| Temperature² (Type-K thermocouple), Accuracy | 1% + 10²; 1% + 18² |
| AC μA true-rms (45 Hz to 500 Hz), Range/resolution | 600.0 μA; 0.1 μA |
| AC μA true-rms (45 Hz to 500 Hz), Accuracy | 1.5% + 3 |
| DC μamps, Range/resolution | 600.0 μA; 0.1 μA |
| DC μamps, Accuracy | 1.0% + 2 |
| Hz (V or A input)², Range/resolution | 99.99 Hz; 0.01 Hz; 999.9 Hz; 0.1 Hz; 9.999 kHz; 0.001 Hz; 50.00 kHz; 0.01 Hz |
| Hz (V or A input)², Accuracy | 0.1% + 2 |
| Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) |
|---|---|
| Weight | 550 g |
| Warranty | 3 years |
| Contents | 4 mm silicone test lead set; 80BK Integrated Temperature probe; Holster; Installed 9 V battery; User manual |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.
About the 116
The Fluke 116 is designed for HVAC work. It has a built-in thermometer for -40 °C to 400 °C and a microamp range for testing flame sensors, alongside resistance, continuity, frequency and capacitance. A low-impedance mode helps prevent ghost-voltage readings and a white LED backlight helps in dark plant rooms.