Fluke 114 True-rms Electrical Multimeter

Brand
Fluke
Model number
114

True-rms multimeter for go/no-go testing with AutoVolt AC/DC selection and LoZ ghost-voltage detection.

Price and availability on request

Request a quote

Sent with the product details: Fluke 114 True-rms Electrical Multimeter.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Ideal Digital Multimeter for “go/no-go” testing
  • Features AutoVolt automatic AC/DC voltage selection
  • Includes low input impedance to help prevent false readings due to ghost voltage
  • Presents a large white LED backlight for working in poorly lit areas
  • Measures resistance and continuity
  • Provides Min/Max/Average with elapsed time to record signal fluctuations

Specifications

Specifications
Maximum voltage between any terminal and earth ground600 V
SafetyIEC 61010-1: Pollution Degree 2; IEC 61010-2-033: CAT III 600V
DisplayDigital: 6,000 counts, updates 4 per second
Bar graph33 segments, updates 32 per second
Operating temperature-10°C to + 50°C
Storage temperature-40°C to + 60°C
Battery type9 volt Alkaline, IEC 6LR61
Battery life400 hours typical, without backlight
Accuracy specifications
DC millivolts, Range/resolution600.0 mV; 0.1 mV
DC millivolts, Accuracy± ([% of reading] + [counts]): 0.5% + 2
DC volts, Range/resolution6.000 V; 0.001; V60.00 V; 0.01; V600.0 V; 0.1 V
DC volts, Accuracy± ([% of reading] + [counts]): 0.5% + 2
Auto volts, Range/resolution600.0 V; 0.1 V
Auto volts, Accuracy2.0% + 3 (DC, 45 Hz to 500 Hz); 4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 True RMS, Range/resolution600.0 mV; 0.1 mV
AC millivolts1 True RMS, Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz); 2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS, Range/resolution6.000 V; 0.001; V60.00 V; 0.01; V600.0 V; 0.1 V
AC volts1 True RMS, Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz); 2.0% + 3 (500 Hz to 1 kHz)
Continuity, Range/resolution600 Ω; 1 Ω
Continuity, AccuracyBeeper on < 20 Ω, off > 250 Ω detects opens or shorts of; 500 μs or longer.
Ohms, Range/resolution600.0 Ω; 0.1 Ω; 6.000 kΩ; 0.001 kΩ; 60.00 kΩ; 0.01 kΩ; 600.0 kΩ; 0.1 kΩ; 6.000 MΩ; 0.001 MΩ; 40.00 MΩ; 0.01 MΩ
Ohms, Accuracy0.9% + 1; 5% + 2
Mechanical & General Specifications
Size167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight550 g
Warranty3 years
Supplied with
ContentsHolster; Installed 9 V battery; Test leads; User manual

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.

About the 114

The Fluke 114 is a compact true-rms meter for quick go/no-go checks. AutoVolt selects AC or DC voltage automatically, and the low-impedance (LoZ) mode helps avoid false readings from ghost voltage. It also measures resistance and continuity, records Min/Max/Average and has a white LED backlight.