Fairchild TXI7800 Explosionproof I/P Pressure Transducer, 4-20 mA, NEMA 4X IP65, FM CSA ATEX IECEx
- Brand
- Fairchild
- Model number
- TXI7800
- Category
- I/P Converters
Fairchild TXI7800 explosionproof I/P transducer, 18 output ranges up to 0-120 psig, 0.15 % FS typical accuracy. Electronics isolated from the air section. FM, CSA, ATEX and IECEx.
Price and availability on request
We reply by email or phone, Monday to Saturday, 10:30 am to 6:30 pm.
Several models? Add each to your enquiry list and send them as one enquiry.
Key features
- Explosionproof NEMA 4X, IP65, Type 4 enclosure
- 18 output ranges, up to 0-120 psig
- Accuracy 0.15 % FS typical
- Field reversible output
- Electronics chamber isolated from pneumatics
- No copper-based metals in the standard range
- Version approved for natural gas or industrial methane supply
- FM, CSA, ATEX and IECEx approvals, CRN
Specifications
| Input signal | 4-20 mA |
|---|---|
| Operating voltage | 8.2 V DC at 20 mA (two-wire) |
| Reverse polarity protection | No damage from reversal or up to 60 mA misapplied |
| Output ranges, standard | 3-15, 3-27 or 6-30 psig (0.2-1.0, 0.2-1.8 or 0.4-2.0 bar) |
|---|---|
| Output ranges, extended | 0-30, 0-60 or 0-120 psig (0-2.0, 0-4.0 or 0-8.0 bar) |
| Supply pressure, standard | 20-120 psig for 3-15 psig, 32-120 psig for 3-27 psig, 35-120 psig for 6-30 psig |
|---|---|
| Supply pressure, extended | 35-150 psig for 0-30 psig, 65-150 psig for 0-60 psig, 125-150 psig for 0-120 psig |
| Flow rate, standard | 2.5 SCFM (4.25 m³/h) at 25 psig supply, 9.0 SCFM (15.3 m³/h) at 120 psig supply, with 9 psig output |
|---|---|
| Flow rate, extended | 11.0 SCFM (18.7 m³/h) at 150 psig supply and midscale output |
| Accuracy (ISA S51.1) | 0.25 % FS guaranteed, 0.15 % FS typical |
|---|---|
| Hysteresis | 0.1 % FS standard, 0.25 % FS extended |
| Repeatability | 0.1 % FS |
| Deadband | 0.02 % FS |
| Supply pressure effect | No measurable effect standard, under 0.1 psig per 10 psig change extended |
| Temperature effect | ±(0.5 % + 0.04 % per °F) of span typical, 0.06 % per °F extended |
| Frequency response | -3 dB at 5 Hz standard, 2 Hz extended |
| Vibration effect | Less than ±1 % of span |
| Operating temperature | -40 to +71.2 °C |
|---|---|
| Storage temperature | -40 to +82.2 °C |
| Enclosure | Explosionproof NEMA 4X, Type 4, IP65 |
|---|---|
| Materials | Chromate treated aluminium body, aluminium and sapphire orifice (nickel plated brass on extended), stainless steel and zinc plated steel trim, nitrile elastomers, epoxy powder coat |
| Electrical connection | 10 ft cable standard, 20, 50 or 100 ft optional |
|---|
| FM | Explosionproof Class I Div. 1 Groups B, C, D, Class II Div. 1 Groups E, F, G, Class III Div. 1, intrinsically safe |
|---|---|
| CSA | Explosionproof and intrinsically safe, Class I and II Div. 1 and 2 |
| ATEX | Flameproof II 2 GD EEx d IIB+H2 T5, intrinsically safe II 1 GD Ex ia IIB T4 Ga |
| IECEx | Ex ia IIB T4 Ga, Ta -40 to +80 °C, IP65 |
| Other | CRN, RoHS compliant |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering. Brand names, logos and model names are trademarks of their respective owners, used only to identify the product. Details
About the TXI7800
Rotork Fairchild TXI7800 is an explosionproof I/P transducer for hazardous areas. It works on the same principles as the T7800, in a NEMA 4X explosionproof enclosure. The electronics chamber is isolated from the pneumatic section, which improves safety and service life, especially on natural gas. The standard range uses no copper-based metals.