Fairchild T5700 I/P Pressure Transducer, 4-20 mA, 3-15 psig, Built-In Regulator, Wall or Panel Mount

Model number
T5700

Fairchild T5700 force-balance I/P transducer, 3-15 psig output, 17 SCFM. Immune to supply changes, 0.05 SCFM air use, built-in regulator, direct or inverse output, split range.

Price and availability on request

We reply by email or phone, Monday to Saturday, 10:30 am to 6:30 pm.

Several models? Add each to your enquiry list and send them as one enquiry.

Request a quote

Sent with the product details: Fairchild T5700 I/P Pressure Transducer, 4-20 mA, 3-15 psig, Built-In Regulator, Wall or Panel Mount.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Low droop under flow
  • Immune to supply pressure changes
  • Low air use, 0.05 SCFM dead end
  • High forward and exhaust capacity
  • Direct or inverse output
  • Split range operation
  • Built-in supply pressure regulator
  • Wall or panel mounting, bracket kit included

Specifications

Input
Input signal4-20 mA, 10-50 mA, 1-5 V DC or 1-9 V DC (factory calibrated for 4-20 mA or 1-9 V DC, field calibratable)
Input impedance4-20 mA 62 ohm, 10-50 mA 26 ohm, 1-5 V DC 510 ohm, 1-9 V DC 1020 ohm
Output
Output range3-15 psig (0.2-1.0 bar)
Supply
Supply pressure18-150 psig (1.2-10.0 bar)
Flow
Flow capacity17 SCFM (28.9 m³/h) at 20 psig supply, 47 SCFM (79.9 m³/h) at 120 psig (8.0 bar) supply
Exhaust capacityOver 9 SCFM (15.3 m³/h) for downstream pressure 5 psig above set point
Air consumption0.05 SCFM (0.08 m³/h) max with 20-120 psig supply
Performance
Linearity, independent±0.5 % of full scale
Linearity, terminal based±1.0 % of full scale
Hysteresis and repeatabilityWithin 0.1 % of full scale
Supply pressure effect±0.3 % of full scale for 50 psig (3.5 bar) change
Environment
Operating temperature-40 to +65 °C
Construction
MaterialsAluminium housing, sapphire orifice, Buna N Dacron fabric diaphragm
General
MountingWall or panel, bracket kit 15396 included

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering. Brand names, logos and model names are trademarks of their respective owners, used only to identify the product. Details

About the T5700

Rotork Fairchild T5700 is an I/P and E/P transducer that converts a current signal into a linear pneumatic output using a force balance system with a flapper and nozzle. Low droop under flow helps hold downstream pressure, and the built-in supply regulator lets it run on normal plant air.