Delta DRV-24V120W1PN 24V 5A 120W DIN Rail Power Supply, CliQ VA Series
- Brand
- Delta
- Model number
- DRV-24V120W1PN
- Category
- DIN-Rail Power Supplies
CliQ VA DIN rail power supply with 24V 5A output (120W) from 85-264Vac or 88-375Vdc. Aluminium case and convection cooling, operating -25 to +70 °C. With an LCD showing output values, power boost and a DC OK signal.
Price and availability on request
Key features
- Universal AC input voltage range
- LCD display monitoring the output current / voltage / peak current and temperature
- Life time expectancy alarm signal and monitoring
- Built-in active PFC with up to 94% efficiency
- Power Boost of 150% up to 7 seconds
- Advanced Power Boost (APB)
- DC OK Contact and LED indicator for DC OK/ Overload
- Conformal coating on PCBAs to protect against common dust and chemical pollutants
- Certified according to IEC/EN/UL 62368-1
Specifications
| Series | CliQ VA Series |
|---|---|
| Mounting | DIN rail |
| Output Current | 5A |
|---|---|
| Output Voltage | 24V |
| Output Voltage Adjustment Range | 24-28Vdc |
| Output Power | 120W |
| Line Regulation | 20mV Max. (@ 85-264Vac input, 100% load) |
| Load Regulation | 100mV Max. (@ 85-264Vac input, 0-100% load) |
| PARD | 50mVpp Max. |
| Start-up Time | 750ms Max. @ 100Vac & 120Vac & 230Vac |
| Hold-up Time | 70ms Typ. @ 100Vac & 120Vac & 230Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 5% @ 0-100% load / Slew rate 0.1A/µs (@ 5Hz, 50Hz & 1kHz, 50% Duty Cycle) |
| Start-up with Capacitive Loads | 10,000µF Max. |
| Rise Time | 20ms Max. @ 100Vac & 120Vac & 230Vac (0µF, 24V, 5A) / 50ms Max. @ 100Vac & 120Vac & 230Vac (5,000µF, 24V, 5A) |
| Power Boost Duration | 5 seconds Typ. / 7 seconds Max. |
| Power Boost Recovery Time | 14 seconds Typ. |
| Nominal Input Voltage | 100-240Vac |
|---|---|
| Input Voltage Range | 85-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Nominal DC Input Voltage | 110-300Vdc |
| DC Input Voltage Range | 88-375Vdc |
| Input Current | 1.34A Typ. @ 100Vac, 1.11A Typ. @ 120Vac, 0.61A Typ. @ 230Vac |
| Efficiency at 100% load | 89.67% Typ. @ 100Vac, 90.62% Typ. @ 120Vac, 91.42% Typ. @ 230Vac |
| Inrush Current | 15.0A Max. @ 100Vac & 120Vac & 230Vac |
| Power Factor at 100% load | 0.99 Typ. @ 100Vac, 0.99 Typ. @ 120Vac, 0.93 Typ. @ 230Vac |
| Leakage Current | (Enclosure to Neutral) / < 0.18mA / 0.46mA @ 110Vac, 50Hz, TN/TT system / IT system / < 0.22mA / 0.54mA @ 132Vac, 50Hz, TN/TT system / IT system / < 0.45mA / 1.08mA @ 264Vac, 50Hz, TN/TT system / IT system |
| Power Dissipation | 0% load: / 3.70W Typ. @ 100Vac, 3.36W Typ. @ 120Vac, 2.70W Typ. @ 230Vac / 3.80W Max. @ 100Vac, 3.90W Max. @ 120Vac, 4.30W Max. @ 230Vac / / 100% load: / 13.85W Typ. @ 100Vac, 12.45W Typ. @ 120Vac, 11.27W Typ. @ 230Vac / 14.00W Max. @ 100Vac, 12.90W Max. @ 120Vac, 11.60W Max. @ 230Vac |
| Case Chassis / Cover | Aluminium and Plastic / Aluminium |
|---|---|
| Indicator | Green LED (DC OK) and Red LED (Overload) |
| Cooling System | Convection |
| Input Terminal | 3 Pins (Rated 600V/35A) |
| Output Terminal | 6 Pins (Rated 300V/28A) |
| Signal Terminal | 2 Pins (Rated 300V/10A) |
| Noise Sound Pressure Level (SPL) | < 25dBA |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Wire | Input: AWG 18-8 / Output: AWG: 18-12 / Signal: AWG 20-16 |
| Unit Weight | 0.75 kg (1.65 lb) |
| Dimensions | 124 x 60 x 139 mm / 4.88” x 2.36” x 5.47” |
| Operating Temperature | -25°C to +70°C |
|---|---|
| Storage Temperature | -40°C to +85°C |
| Power De-rating | Vertical Mounting: > 60°C de-rate power by 2.5% / °C / Horizontal Mounting: > 50°C de-rate power by 2.5% / °C |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 30G for a duration of 18ms; 3 times per direction, 6 times in total |
| Vibration (Non-Operating) | IEC 60068-2-6, Sine Wave: 10-500Hz; 3G peak; displacement of 0.35mm; 60 min per axis for all X, Y, Z directions |
| Operating Altitude | 0 to 5,000 Meters (16,400 ft.) |
| Pollution Degree | 2 |
| Bump Test (Operating) | IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total |
| Over Voltage Category | III / According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part) |
| Overvoltage | 28.8 – 35.2V, SELV Output, Hiccup Mode, Non-Latching (Auto-Recovery) |
|---|---|
| Overload / Overcurrent | > 150% of rated load current, Constant current, Hiccup Mode (Auto-Recovery) |
| Over Temperature | < 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery) |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Degree of Protection | IP20 |
| Protection Against Shock | Class I with Primary Earth connection |
| MTBF | 1,444,000 hrs. (I/P: 100Vac, O/P: 24V, 5A, Ta: 25°C) / 801,000 hrs. (I/P: 100Vac, O/P: 24V, 5A, Ta: 40°C) |
|---|---|
| Expected Cap Life Time | 131,400 hrs. @ 100Vac & 230Vac (O/P: 24V, 5A, Ta: 25°C) / 92,230 hrs. @ 100Vac (O/P: 24V, 5A, Ta: 40°C) / 98,540 hrs. @ 230Vac (O/P: 24V, 5A, Ta: 40°C) / 131,400 hrs. @ 100Vac & 230Vac (O/P: 24V, 2.5A, Ta: 40°C) |
| Electrical Safety | SIQ Bauart: EN 62368-1, EN 61010-1, EN 61010-2-201 / UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) / CB scheme: IEC 60950-1, IEC 62368-1, IEC 61010-1, IEC 61010-2-201 / UKCA: IEC 62368-1, IEC 61010-1, IEC 61010-2-201 |
|---|---|
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| Galvanic Isolation | Input / Output: 3.0 KVac / Input / PE: 2.0 KVac / Input / DC OK relay contact: 3.0 KVac (Recommend to connect DC OK pins together with output pins) / Output / PE: 1.5 KVac / Output / DC OK relay contact: 0.5 KVac / DC OK relay contact / PE: 1.5 KVac |
| Industrial Control Equipment | UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355) |
| Electrical Equipments of Machines | EN/BS EN 60204-1 (over voltage category III) |
| Electrical Equipment for Use in Electrical Power Installations | IEC/EN/BS EN 62477-1 / IEC 62103 |
| Safety Entry Low Voltage | SELV (IEC 60950-1) |
| Isolation Resistance | > 5 MOhm (Input to Output, 500 Vdc) |
| PE Resistance | < 0.1 Ohm |
| UKCA | In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091 |
| Emission | (CE & RE) / Generic Standards: EN/BS EN 61000-6-3 CISPR 32, EN/BS EN 55032, CISPR 11, EN/BS EN 55011, FCC Title 47: Class B |
|---|---|
| Immunity | Generic Standards: EN/BS EN 55024, EN/BS EN 61000-6-2 |
| Harmonic Current Emissions | IEC/EN/BS EN 61000-3-2, Class A |
| Voltage Fluctuation and Flicker | IEC/EN/BS EN 61000-3-3 |
| Component Power Supply for General Use | EN/BS EN 61204-3 |
| Tags | Conformal Coating, LCD Display |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.