Delta DRP-24V120W2BN 24V 5A 120W DIN Rail Power Supply, CliQ II Series

Brand
Delta
Model number
DRP-24V120W2BN

CliQ II DIN rail power supply with 24V 5A output (120W) from 2 x 180-550Vac / 180-305Vac or 254-780Vdc. Aluminium case and convection cooling, operating -30 to +70 °C. With a DC OK signal and conformal-coated boards.

Price and availability on request

Request a quote

Sent with the product details: Delta DRP-24V120W2BN 24V 5A 120W DIN Rail Power Supply, CliQ II Series.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Designed for single phase input 180-305Vac (for L-N) or 2 of 3-Phase system 2 x 180-550Vac (for L-L) or 254-780Vdc
  • Compact and corrosion resistant aluminium casing
  • High Efficiency > 90.0%
  • Conforms to harmonic current IEC/EN 61000-3-2, Class A
  • Wide operating temperature range from -30°C to +70°C
  • Built-in DC OK Contact
  • Conformal coating on PCBAs to protect against common dust and chemical pollutants
  • Certified according to IEC/EN/UL 62368-1

Specifications

Product
SeriesCliQ II Series
MountingDIN rail
Output
Output Current5A
Output Voltage24V
Output Voltage Adjustment Range24-28Vdc
Output Power120W
Line Regulation< 0.5% (@ 200-550Vac input, 100% load)
Load Regulation< 1.0% (@ 200-550Vac input, 0-100% load)
PARD< 150mVpp
Start-up Time< 2,500ms @ nominal input (100% load)
Hold-up Time> 10ms @ 2 x 230Vac, / > 50ms @ 2 x 400Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 5% @ 180-550Vac input, 0-100% load / (Slew Rate: 0.1A/μs, 50% duty cycle @ 5Hz to 1KHz)
Start-up with Capacitive Loads5,000µF Max
Rise Time< 70ms @ nominal input (100% load)
Input
Nominal Input Voltage2 x 200-500Vac (2-Phase) / 200-277Vac (Single Phase)
Input Voltage Range2 x 180-550Vac (2-Phase) / 180-305Vac (Single Phase)
Nominal Input Frequency50-60Hz
Input Frequency Range47-63Hz
DC Input Voltage Range254-780Vdc
Input Current< 1.20A @ 2 x 230Vac, / < 0.80A @ 2 x 400Vac
Efficiency at 100% load> 90.0% @ 2 x 400Vac
Inrush Current< 50A @ 2 x 200Vac
Leakage Current< 1mA @ 500Vac
Power Dissipation0% load: < 1.7W @ 2 x 200Vac, < 3.2W @ 2 x 500Vac / 100% load: < 17W @ 2 x 200Vac, < 15W @ 2 x 500Vac
Mechanical
Case Chassis / CoverAluminium
IndicatorGreen LED (DC OK)
Cooling SystemConvection
Input Terminal3 Pins (Rated 600V/35A)
Output Terminal4 Pins (Rated 300V/28A)
Noise Sound Pressure Level (SPL)< 40dBA
Mounting RailStandard TS35 DIN Rail in accordance with EN 60715
WireInput: AWG 18-8 / Output: AWG 18-12
Unit Weight0.62 kg (1.37 lb)
Dimensions124 x 40 x 117 mm / 4.88” x 1.57” x 4.61”
Environment
Operating Temperature-30°C to +70°C
Storage Temperature-40°C to +85°C
Power De-ratingVertical: > 60°C de-rate power by 4% / °C / Horizontal: > 50°C de-rate power by 4% / °C / Input Voltage: < 200Vac de-rate power by 2% / Vac / Cold Start: < -10°C de-rate power by 2.5% / °C
Operating Humidity5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms, 3 times per direction, 6 times in total
Vibration (Non-Operating)IEC 60068-2-6, 10Hz to 500Hz @ 30m/S² (3G peak); 60 min per axis for all X, Y, Z direction
Operating Altitude0 to 2,500 Meters (8,200 ft.) for ITE application (@ 60°C) / 0 to 2,000 Meters (6,560 ft.) for Industrial application (@ 60°C)
Pollution Degree2
Bump Test (Operating)IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total
Over Voltage CategoryIII / According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part)
Protections
Overvoltage32V ±10%, SELV Output, Hiccup Mode, Non-Latching (Auto-Recovery)
Overload / Overcurrent> 120-160% of rated load current, Constant current, Hiccup Mode (Auto-Recovery)
Over Temperature< 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery)
Short CircuitHiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Degree of ProtectionIP20
Protection Against ShockClass I with Primary Earth connection
Reliability
MTBF> 800,000 hrs. as per Telcordia SR-332 (I/P: 2 x 200Vac & 500Vac, O/P: 100% load, Ta: 25°C)
Expected Cap Life Time10 years (2 x 200Vac & 500Vac, 50% load @ 40°C)
Safety
Electrical SafetySIQ Bauart: EN 62368-1 / UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) / CB scheme: IEC 60950-1, IEC 62368-1 / UKCA: BS EN 62368-1
CEIn conformance with EMC Directive 2014/30/EU (only AC input) and Low Voltage Directive 2014/35/EU
Galvanic IsolationInput to Output: 4.0 KVac / Input to Ground: 2.0 KVac / Output to Ground: 1.5 KVac
Industrial Control EquipmentUL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355) / CSA: CSA C22.2 No. 107.1-01 (File No. 181564)
Electrical Equipments of MachinesEN/BS EN 60204-1 (over voltage category III)
Electrical Equipment for Use in Electrical Power InstallationsIEC/EN/BS EN 62477-1 / IEC 62103
Safety Entry Low VoltageSELV (IEC 60950-1)
UKCAIn conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091
EMC
Emission(CE & RE) / Generic Standards: CISPR 32, EN/BS EN 55032, CISPR 11, EN/BS EN 55011, FCC Title 47: Class B
ImmunityGeneric Standards: EN/BS EN 55024, EN/BS EN 61000-6-2
Harmonic Current EmissionsIEC/EN/BS EN 61000-3-2, Class A
Voltage Fluctuation and FlickerIEC/EN/BS EN 61000-3-3
Component Power Supply for General UseEN/BS EN 61204-3
Other
Tags2 phase, Conformal Coating

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.