Delta DRP-24V120W1CBN 24V 5A 120W DIN Rail Power Supply, CliQ III Series
- Brand
- Delta
- Model number
- DRP-24V120W1CBN
- Category
- DIN-Rail Power Supplies
CliQ III DIN rail power supply with 24V 5A output (120W) from 88-264Vac. Aluminium case and convection cooling, operating -25 to +70 °C. With power boost, a constant-current mode and a DC OK signal.
Price and availability on request
Key features
- Universal AC input voltage range
- Built-in constant current circuit for charging application
- High efficiency of up to 91% at 230Vac
- Power Boost of 150% for 5 seconds
- Advanced Power Boost (APB) of 200% for 50ms
- SEMI F47 compliance at 120Vac
- Extreme low temperature cold start at -40°C
- Built-in DC OK Contact and LED indicator for DC OK
- Conformal coating on PCBAs to protect against common dust and chemical pollutants
- Certified according to IEC/EN/UL 62368-1
Specifications
| Series | CliQ III Series |
|---|---|
| Mounting | DIN rail |
| Output Current | 5A |
|---|---|
| Output Voltage | 24V |
| Output Voltage Adjustment Range | 24-28Vdc |
| Output Power | 120W |
| Line Regulation | 0.5% (@ 88-264Vac input, 100% load) |
| Load Regulation | 1.0% (@ 88-264Vac input, 0-100% load) |
| PARD | 100mVpp Max. |
| Start-up Time | 1,500ms Max. @ 24V, 5A |
| Hold-up Time | 35ms Typ. @ 24V, 5A / 20ms Min. @ 24V, 5A |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 5% @ 0-100% load / Slew rate 0.1A/µs (@ 5Hz, 50Hz & 1kHz, 50% Duty Cycle) |
| Start-up with Capacitive Loads | 10,000µF |
| Rise Time | 60ms Max. @ 24V, 5A |
| Power Boost Duration | 5 seconds Min. |
| Power Boost Recovery Time | 18 seconds Typ. |
| Nominal Input Voltage | 100-240Vac |
|---|---|
| Input Voltage Range | 88-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| DC Input Voltage Range | 100-375Vdc (Continuously operating, with safety approval according to IEC/EN/UL 60950-1) / 88-100Vdc (With power de-rating) |
| Input Current | 1.18A Typ. @ 115 Vac, 0.61A Typ. @ 230Vac |
| Efficiency at 100% load | 89.92% Typ. @ 115Vac, 91.49% Typ. @ 230Vac |
| Inrush Current | (Cold Start) / 12.4A Typ. @ 115Vac, 25.6A Typ. @ 230Vac, 35A Max. @ 115Vac, 70A Max. @ 230Vac |
| Power Factor at 100% load | 0.98 Typ. @ 115Vac, 0.95 Typ. @ 230Vac, 0.96 Min. @ 115Vac, 0.93 Min. @ 230Vac |
| Leakage Current | (Enclosure to Neutral) / < 0.20mA / 0.50mA: 110Vac, 50Hz, TN/TT system / IT system / < 0.24mA / 0.60mA: 132Vac, 50Hz, TN/TT system / IT system / < 0.47mA / 1.20mA: 264Vac, 50Hz, TN/TT system / IT system |
| Power Dissipation | At 24V, 0A: 3.31W Typ. @ 115Vac, 3.20W Typ. @ 230Vac, 5.0W Max. @ 115Vac, 5.0W Max. @ 230Vac / At 24V, 5A: 13.46W Typ. @ 115Vac, 11.16W Typ. @ 230Vac, 14.0W Max. @ 115Vac, 13.0W Max. @ 230Vac |
| Case Chassis / Cover | Aluminium |
|---|---|
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Input Terminal | 3 Pins (Rated 600V/35A) |
| Output Terminal | 4 Pins (Rated 300V/28A) |
| Signal Terminal | 2 Pins (Rated 300V/28A) |
| Noise Sound Pressure Level (SPL) | < 25dBA |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Wire | Input: AWG 18-8 / Output: AWG 18-12 / Signal: AWG 18-12 |
| Unit Weight | 0.58 kg (1.28 lb) |
| Dimensions | 124 x 40 x 117 mm / 4.88” x 1.57” x 4.61” |
| Operating Temperature | -25°C to +70°C (Cold start -40°C) |
|---|---|
| Storage Temperature | -40°C to +85°C |
| Power De-rating | Vertical Mounting: > 60°C de-rate power by 2.5% / °C / Horizontal Mounting: > 40°C de-rate power by 1.67% / °C / Input Voltage: / AC input < 100Vac de-rate power by 0.83% / V / DC input < 100Vdc de-rate power by 1.67% / V |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 30G for a duration of 18ms; 3 times per direction, 9 times in total |
| Vibration (Non-Operating) | IEC 60068-2-6, Sine Wave: 10-500Hz; 3G peak; displacement of 0.35mm; 60 min per axis for all X, Y, Z directions |
| Operating Altitude | 0 to 5,000 Meters (16,400 ft.) |
| Pollution Degree | 2 |
| Bump Test (Operating) | IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total |
| Over Voltage Category | III (operating altitude 2,500 Meters) / II (operating altitude 5,000 Meters) / According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part) |
| Overvoltage | 28.8 - 35.2V, SELV Output, Hiccup Mode, Non-Latching (Auto-Recovery) |
|---|---|
| Overload / Overcurrent | 125 – 170% of rated load current, Constant current, Hiccup Mode (Auto-Recovery) |
| Over Temperature | < 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery) |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed): Load impedance ≤ 100mOhm |
| Degree of Protection | IP20 |
| Protection Against Shock | Class I with Primary Earth connection |
| MTBF | 1,411,300 hrs.: I/P: 115Vac, O/P: 24V, 5A, Ta: 25°C / 842,900 hrs.: I/P: 115Vac, O/P: 24V, 5A, Ta: 40°C |
|---|---|
| Expected Cap Life Time | O/P: 24V, 5A, Ta: 25°C: 131,400hrs. @ 115Vac & 230Vac / O/P: 24V, 2.5A, Ta: 40°C: 131,400hrs. @ 115Vac & 230Vac / O/P: 24V, 5A, Ta: 60°C: 21,100hrs. @ 115Vac, 32,700hrs. @ 230Vac / O/P: 24V, 3.75A, Ta: 60°C: 29,700hrs.@ 115Vac, 47,300hrs. @ 230Vac |
| Electrical Safety | SIQ Bauart: EN 62368-1 / UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) / CB scheme: IEC 60950-1, IEC 62368-1 / UKCA: BS EN 62368-1 |
|---|---|
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| Galvanic Isolation | Input to Output: 4.0 KVac / Input to Ground: 2.0 KVac / Input to DC OK relay contact: 4.0 KVac / Output to Ground: 1.5 KVac / Output to DC OK relay contact: 0.5 KVac / DC OK relay contact to PE: 1.5 KVac |
| Industrial Control Equipment | UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355) |
| Electrical Equipments of Machines | EN/BS EN 60204-1 (over voltage category III) |
| Electrical Equipment for Use in Electrical Power Installations | IEC/EN 62477-1 / IEC 62103 |
| Safety Entry Low Voltage | SELV (IEC 60950-1) |
| PE Resistance | < 0.1 Ohm |
| UKCA | In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091 |
| Emission | (CE & RE) / Generic Standards: EN/BS EN 61000-6-3 CISPR 32, EN/BS EN 55032, CISPR 11, EN/BS EN 55011, FCC Title 47: Class B |
|---|---|
| Immunity | Generic Standards: EN/BS EN 55024, EN/BS EN 61000-6-2 |
| Harmonic Current Emissions | IEC/EN/BS EN 61000-3-2, Class A |
| Voltage Fluctuation and Flicker | IEC/EN/BS EN 61000-3-3 |
| Component Power Supply for General Use | EN/BS EN 61204-3 |
| Tags | Conformal Coating |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.