Delta DRP-24V100W1NN 24V 3.8A 91W DIN Rail Power Supply, CliQ II Series

Brand
Delta
Model number
DRP-24V100W1NN

CliQ II DIN rail power supply with 24V 3.8A output (91W) from 85-264Vac or 120-375Vdc. Aluminium case and convection cooling, operating -25 to +80 °C. With NEC Class 2 rating, active PFC and conformal-coated boards.

Price and availability on request

Request a quote

Sent with the product details: Delta DRP-24V100W1NN 24V 3.8A 91W DIN Rail Power Supply, CliQ II Series.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Universal AC input voltage range
  • Power will not de-rate for the entire input voltage range
  • UL 1310 safety approval
  • Built-in active PFC, PF > 0.99 @ 115Vac
  • Full corrosion resistant aluminium casing
  • NEC Class 2 and Limited Power Source (LPS) approvals
  • Conforms to harmonic current IEC/EN 61000-3-2, Class A
  • Conformal coating on PCBAs to protect against common dust and chemical pollutants
  • Overvoltage / Overcurrent / Over Temperature / Short Circuit Protections
  • Certified according to IEC/EN/UL 62368-1

Specifications

Product
SeriesCliQ II Series
MountingDIN rail
Output
Output Current3.8A
Output Voltage24V
Output Voltage Adjustment Range22-24Vdc
Output Power91W
Line Regulation< 0.5% (@ 85-264Vac input, 100% load)
Load Regulation< 1.0% at -25°C to +25°C / < 2.0% at +25°C to +50°C / (@ 85-264Vac input, 0-100% load)
PARD< 150mVpp
Start-up Time< 2,000ms @ nominal input (100% load)
Hold-up Time> 20ms @ 115Vac, / > 30ms @ 230Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 5% @ 85-264Vac input, 0-100% load / (Slew Rate: 0.1A/μs, 50% duty cycle @ 5Hz to 1kHz)
Start-up with Capacitive Loads8,000μF Max
Rise Time< 100ms @ nominal input (100% load)
Input
Nominal Input Voltage100-240Vac
Input Voltage Range85-264Vac
Nominal Input Frequency50-60Hz
Input Frequency Range47-63Hz
DC Input Voltage Range120-375Vdc
Input Current< 1.00A @ 115Vac, / < 0.53A @ 230Vac
Efficiency at 100% load> 88.0% @ 115Vac, / > 89.0% @ 230Vac
Inrush Current< 30A @ 115Vac, / < 60A @ 230Vac
Power Factor at 100% load> 0.99 @ 115Vac, / > 0.94 @ 230Vac
Leakage Current< 0.5mA @ 240Vac
Power Dissipation0% load: < 0.7W @ 115Vac, < 0.8W @ 230Vac / 100% load: < 12.4W @ 115Vac, < 11.2W @ 230Vac
Mechanical
Case Chassis / CoverAluminium
IndicatorGreen LED (DC OK)
Cooling SystemConvection
Input Terminal3 Pins (Rated 600V/35A)
Output Terminal4 Pins (Rated 300V/28A)
Noise Sound Pressure Level (SPL)< 40dBA
Mounting RailStandard TS35 DIN Rail in accordance with EN 60715
WireInput / Output: AWG 18-12
Unit Weight0.60 kg (1.32 lb)
Dimensions124 x 40 x 124 mm / 4.88” x 1.57” x 4.88”
Environment
Operating Temperature-25°C to +80°C (Cold Start at -40°C)
Storage Temperature-40°C to +85°C
Power De-ratingVertical: > 50°C de-rate power by 2.5% / °C, > 70°C de-rate power by 4% / °C / Horizontal: > 40°C de-rate power by 2.5% / °C
Operating Humidity5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms, 1 times per direction, 2 times in total
Vibration (Non-Operating)IEC 60068-2-6, 10Hz to 500Hz @ 30m/S² (3G peak); 60 min per axis for all X, Y, Z direction
Operating Altitude0 to 2,500 Meters (8,200 ft)
Pollution Degree2
Bump Test (Operating)IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total
Over Voltage CategoryIII / According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part)
Protections
Overvoltage< 32V, ±10%, SELV Output, Hiccup Mode, Non-Latching (Auto-Recovery)
Over Temperature< 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery)
Short CircuitHiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Degree of ProtectionIP20
Protection Against ShockClass I with Primary Earth connection
Overload< 100W, Constant Current, Hiccup Mode, Non-Latching (Auto-Recovery)
Overcurrent< 8A, Constant Current, Hiccup Mode, Non-Latching (Auto-Recovery)
Reliability
MTBF> 800,000 hrs. as per Telcordia SR-332 (I/P: 115Vac, O/P: 100% load, Ta: 25°C)
Expected Cap Life Time10 years (115Vac & 230Vac, 50% load @ 40°C)
Safety
Electrical SafetySIQ Bauart: EN 62368-1 / UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) / CB scheme: IEC 60950-1, IEC 62368-1 / Limited Power Source (LPS) / UKCA: BS EN 62368-1
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Galvanic IsolationInput to Output: 4.0KVac / Input to Ground: 1.5KVac / Output to Ground: 1.5KVac
Industrial Control EquipmentUL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355) / CSA: CSA to CSA C22.2 No. 107.1-01 (File No. 181564)
Electrical Equipments of MachinesEN/BS EN 60204-1 (over voltage category III)
Electrical Equipment for Use in Electrical Power InstallationsEN/BS EN 62477-1 / IEC 62103
Safety Entry Low VoltageSELV (IEC 60950-1)
UKCAIn conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091
EMC
Emission(CE & RE) / Generic Standards: CISPR 32, EN/BS EN 55032, CISPR 11, EN/BS EN 55011, FCC Title 47: Class B
ImmunityGeneric Standards: EN/BS EN 55024, EN/BS EN 61000-6-2
Harmonic Current EmissionsIEC/EN/BS EN 61000-3-2, Class A
Voltage Fluctuation and FlickerIEC/EN/BS EN 61000-3-3
Component Power Supply for General UseEN/BS EN 61204-3
Other
TagsNEC Class 2, Conformal Coating