Delta DRM-24V960W3PN 24V 40A 960W 3-Phase DIN Rail Power Supply, CliQ M Series
- Brand
- Delta
- Model number
- DRM-24V960W3PN
- Category
- DIN-Rail Power Supplies
CliQ M DIN rail power supply with 24V 40A output (960W) from 3 x 320-575Vac or 450-800Vdc. Aluminium case and convection cooling, operating -25 to +70 °C. With power boost, a constant-current mode and a DC OK signal.
Price and availability on request
Key features
- Built-in constant current circuit for charging application
- Full power from -25°C to +60°C @ 5,000m (16,400 ft.)
- Power Boost of 150% up to 7 seconds
- Advanced Power Boost (APB) – protect system and ensure continuing operation when large inrush current detected due to faulty load on a multiple load connection
- DNV GL and ABS approvals for maritime applications
- Built-in DC OK Contact and LED indicator for DC OK/ Overload
- Conformal coating on PCBAs to protect against common dust and chemical pollutants
Specifications
| Series | CliQ M Series |
|---|---|
| Mounting | DIN rail |
| Output Current | 40A |
|---|---|
| Output Voltage | 24V |
| Output Voltage Range | 24-28Vdc |
| Output Voltage Adjustment Range | 24-28Vdc |
| Output Power | 960W |
| Line Regulation | 10mV (@ 3 x 320-575Vac input, 100% load) |
| Load Regulation | 80mV (@ 3 x 320-575Vac input, 0-100% load) |
| PARD | 100mVpp Max. |
| Start-up Time | 1,000ms @ 24V, 40A |
| Hold-up Time | 50.4ms @ 24V, 20A |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 5% @ 1.5-100% load |
| Start-up with Capacitive Loads | 40,000μF |
| Rise Time | 65ms |
| Power Boost Duration | 5 seconds Typ. / 7 seconds Max. |
| Power Boost Recovery Time | 17 seconds Typ. |
| Nominal Input Voltage | 3 x 400-500Vac |
|---|---|
| Input Voltage Range | 3 x 320-575Vac (3-Phase) or 2 x 380-575Vac (2-Phase) |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| DC Input Voltage Range | 450-800Vdc |
| Input Current | 1.53A @ 24V, 40A |
| Efficiency at 100% load | 95.75% @ 24V, 40A |
| Inrush Current | 14.2A |
| Power Factor at 100% load | 0.95 @ 24V, 40A |
| Leakage Current | < 0.62mA / 0.64mA @ 3 x400Vac, 50Hz, TN/TT / IT system |
| Case Chassis / Cover | Aluminium |
|---|---|
| Indicator | Green LED DC OK / Red LED Overload |
| Cooling System | Convection |
| Input Terminal | 4 Pins (Rated 600V/35A) |
| Output Terminal | 4 Pins (Rated 300V/65A) |
| Signal Terminal | 5 Pins (Rated 300V/12A) |
| Noise Sound Pressure Level (SPL) | < 25dBA |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Unit Weight | 2.3kg (5.07 lb) |
| Dimensions | 124 x 110 x 128.6 mm / 4.88” x 4.33” x 5.06” |
| Operating Temperature | -25°C to +70°C (Cold start -40°C) |
|---|---|
| Storage Temperature | -40°C to +85°C |
| Power De-rating | Vertical Mounting: 3-Phase : > 60°C de-rate power by 2.5% / °C 2-Phase: > 50°C de-rate power by 2.5% / °C / Horizontal Mounting : 3-Phase: > 40°C de-rate power by 1.67% / °C 2-Phase: > 40°C de-rate power by 2% / °C |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 30G for a duration of 18ms; 3 times per direction, 6 times in total |
| Vibration (Non-Operating) | IEC 60068-2-6, Sine Wave: 10-500Hz; 3G peak; displacement of 0.35mm; 60 min per axis for all X, Y, Z directions |
| Operating Altitude | OVC III : 0 to 2,500 Meters (8,200 ft.) / OVC II : 2,500 to 6,000 Meters (19,680 ft.), 0 to 5,000 Meters (16,400 ft.), 0 to 3,000 Meters (9,840 ft.) |
| Pollution Degree | 2 |
| Bump Test (Operating) | IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total |
| Overvoltage | < 32V, SELV Output, Hiccup Mode, Non-Latching (Auto- Recovery) |
|---|---|
| Overload / Overcurrent | 150-200% of rated load current, Constant current, Hiccup Mode (Auto-Recovery) |
| Over Temperature | < 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery) |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Degree of Protection | IP20 |
| Protection Against Shock | Class I with Primary Earth connection |
| MTBF | 568,300 hrs. as per Telcordia SR-332 / I/P: 3 x 400Vac, O/P: 24V, 40A, Ta: 25°C |
|---|---|
| Expected Cap Life Time | 368,800 hrs. @ I/P: 3 x 400Vac, O/P: 24V, 20A, Ta: 25°C |
| Electrical Safety | SIQ Bauart: EN 62368-1, EN 61558-1, EN 61558-2-16, EN 61010-1, EN 61010-2-201 / UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395) UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) / CB scheme: IEC 60950-1, IEC 62368-1, IEC 61558-1, IEC 61558-2-16, IEC 61010-1, IEC 61010-2-201 / UKCA: BS EN 62368-1, BS EN 61558-1, BS EN 61558-2-16, BS EN 61010-1, BS EN 61010-2-201 |
|---|---|
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| Industrial Control Equipment | UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355) |
| Electrical Equipments of Machines | EN/BS EN 60204-1 (over voltage category III) |
| Electrical Equipment for Use in Electrical Power Installations | IEC/EN/BS EN 62477-1 / IEC 62103 |
| Safety Entry Low Voltage | SELV (IEC 60950-1) |
| Maritime | DNV GL: Germanischer Lloyd classified / ABS: American Bureau for Shipping PDA / Environmental category: C, EMC2 |
| Isolation Resistance | > 5MOhm Input to Output, 500Vdc |
| PE Resistance | < 0.1Ohm |
| UKCA | In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091 |
| Emission | (CE & RE) / Generic Standards: EN/BS EN 61000-6-3 CISPR 32, EN/BS EN 55032, CISPR 11, EN/BS EN 55011, FCC Title 47: Class B |
|---|---|
| Immunity | Generic Standards: EN/BS EN 55024, EN/BS EN 55035, EN 61000-6-2 |
| Harmonic Current Emissions | IEC/EN/BS EN 61000-3-2, Class A |
| Voltage Fluctuation and Flicker | IEC/EN/BS EN 61000-3-3 |
| Component Power Supply for General Use | EN/BS EN 61204-3 |
| Tags | 3 phase |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.