CliQ M DIN rail power supply with 24V 3.4A output (81.6W) from 85-276Vac or 88-375Vdc. Aluminium case and convection cooling, operating -25 to +70 °C. With power boost, a DC OK signal and maritime approvals.
Price and availability on request
Key features
- Universal AC input voltage range
- High power density in corrosion resistant aluminium casing
- Power Boost of 150% up to 7 seconds
- Advanced Power Boost (APB)
- DNV GL and ABS approvals for maritime applications
- Extreme low temperature cold start at -40°C
- Built-in DC OK Contact and LED indicator for DC OK/ Overload
- Conformal coating on PCBAs to protect against common dust and chemical pollutants
- Certified according to IEC/EN/UL 62368-1
Specifications
| Series | CliQ M Series |
|---|---|
| Mounting | DIN rail |
| Output Current | 3.4A |
|---|---|
| Output Voltage | 24V |
| Output Voltage Adjustment Range | 24-28Vdc |
| Output Power | 81.6W |
| Line Regulation | 10mV Max. (@ 85-276Vac input, 100% load) |
| Load Regulation | 100mV Max. (@ 85-276Vac input, 0-100% load) |
| PARD | 50mVpp Max. |
| Start-up Time | 430ms Max. @ 100Vac, / 370ms Max. @ 120Vac, / 330ms Max. @ 230Vac |
| Hold-up Time | 40ms Typ. @ 100Vac, / 40ms Typ. @ 120Vac, / 118ms Typ. @ 230Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 5% @ 0-100% load / Slew rate 0.1A/µs (@ 5Hz, 50Hz & 1kHz, 50% Duty Cycle) |
| Start-up with Capacitive Loads | 8,000µF Max. |
| Rise Time | 15ms Max. @ 100Vac & 120Vac & 230Vac (0µF, 24V, 3.4A) / 55ms Max. @ 100Vac & 120Vac & 230Vac (5,000µF, 24V, 10A) |
| Power Boost Duration | 5 seconds Typ. / 7 seconds Max. |
| Power Boost Recovery Time | 14 seconds Typ. |
| Nominal Input Voltage | 100-240Vac |
|---|---|
| Input Voltage Range | 85-276Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Nominal DC Input Voltage | 110-300Vdc |
| DC Input Voltage Range | 88-375Vdc |
| Input Current | 0.91A Typ. @ 100Vac, 0.76A Typ. @ 120Vac, 0.44A Typ. @ 230Vac |
| Efficiency at 100% load | 90.95% Typ. @ 100Vac, 91.49% Typ. @ 120Vac, 91.31% Typ. @ 230Vac |
| Inrush Current | 6.0A Max. @ 100Vac, 7.0A Max. @ 120Vac, 13.0A Max. @ 230Vac |
| Power Factor at 100% load | 0.99 Typ. @ 100Vac, 0.98 Typ. @ 120Vac, 0.89 Typ. @ 230Vac |
| Leakage Current | (Enclosure to Neutral) / < 0.14mA / 0.33mA @ 110Vac, 50Hz, TN/TT system / IT system / < 0.20mA / 0.46mA @ 132Vac, 50Hz, TN/TT system / IT system / < 0.36mA / 0.95mA @ 264Vac, 50Hz, TN/TT system / IT system |
| Power Dissipation | 0% load: / 1.19W Typ. @ 100Vac, 1.19W Typ. @ 120Vac, 1.29W Typ. @ 230Vac / 1.5W Max. @ 100Vac & 120Vac & 230Vac / / 100% load: / 8.16W Typ. @ 100Vac, 7.63W Typ. @ 120Vac, 7.81W Typ. @ 230Vac / 9.5W Max. @ 100Vac, 8.8W Max. @ 120Vac, 9.1W Max. @ 230Vac |
| Case Chassis / Cover | Aluminium |
|---|---|
| Indicator | Green LED (DC OK) and Red LED (Overload) |
| Cooling System | Convection |
| Input Terminal | 3 Pins (Rated 600V/35A) |
| Output Terminal | 6 Pins (Rated 300V/8A) |
| Noise Sound Pressure Level (SPL) | < 25dBA |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Wire | Input: AWG 18-8 / Output: AWG: 20-16 |
| Unit Weight | 0.50 kg (1.10 lb) |
| Dimensions | 124 x 32 x 102 mm / 4.88” x 1.26” x 4.02” |
| Operating Temperature | -25°C to +70°C (Cold start -40°C) |
|---|---|
| Storage Temperature | -40°C to +85°C |
| Power De-rating | Vertical Mounting: > 60°C de-rate power by 2.5% / °C / Horizontal Mounting: > 50°C de-rate power by 2.5% / °C |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC60068-2-27, Half Sine Wave: 30G for a duration of 18ms; 3 times per direction, 6 times in total |
| Vibration (Non-Operating) | IEC 60068-2-6, Sine Wave: 10-500Hz; 3G peak; displacement of 0.35mm; 60 min per axis for all X, Y, Z directions |
| Operating Altitude | 0 to 5,000 Meters (16,400 ft.) for ITE application / 0 to 2,500 Meters (8,200 ft.) for Industrial application |
| Pollution Degree | 2 |
| Bump Test (Operating) | IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total |
| Over Voltage Category | III / According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part) |
| Overvoltage | 28.8 – 35.2V, SELV Output, Hiccup Mode, Non-Latching (Auto-Recovery) |
|---|---|
| Overload / Overcurrent | > 150% of rated load current, Constant current limit, Auto- Recovery when the fault is removed |
| Over Temperature | < 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery) |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Degree of Protection | IP20 |
| Protection Against Shock | Class I with Primary Earth connection |
| MTBF | 2,164,300 hrs. (I/P: 100Vac, O/P: 24V, 3.4A, Ta: 25°C) / 1,341,200 hrs. (I/P: 100Vac, O/P: 24V, 5A, Ta: 40°C) |
|---|---|
| Expected Cap Life Time | 131,400 hrs. @ 100Vac & 230Vac (O/P: 24V, 3.4A, Ta: 25°C) / 131,400 hrs. @ 100Vac & 230Vac (O/P: 24V, 3.4A, Ta: 40°C) / 131,400 hrs. @ 100Vac & 230Vac (O/P: 24V, 1.7A, Ta: 40°C) |
| Electrical Safety | SIQ Bauart: EN 62368-1, EN 61558-1, EN 61558-2-16, EN 61010-1, EN 61010-2-201 / UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) / CB scheme: IEC 60950-1, IEC 62368-1, IEC 61558-1, IEC 61558-2-16, IEC 61010-1, IEC 61010-2-201 / UKCA: BS EN 62368-1, BS EN 61558-1, BS EN 61558-2-16, BS EN 61010-1, BS EN 61010-2-201 |
|---|---|
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| Galvanic Isolation | Input / Output: 4.54 KVac / Input / PE: 2.5 KVac / Input / DC OK relay contact: 4.54 KVac (Recommend to connect DC OK pins together with output pins) / Output / PE: 1.5 KVac / Output / DC OK relay contact: 0.5 KVac / DC OK relay contact / PE: 1.5 KVac |
| Industrial Control Equipment | UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355) / CSA: CSA C22.2 No. 107.1-01 (File No. 181564) |
| Electrical Equipments of Machines | EN/BS EN 60204-1 (over voltage category III) |
| Electrical Equipment for Use in Electrical Power Installations | IEC/EN/BS EN 62477-1 / IEC 62103 |
| Safety Entry Low Voltage | SELV (IEC 60950-1) |
| Maritime | DNV GL: Germanischer Lloyd classified / ABS: American Bureau for Shipping) PDA Environmental category: C, EMC2 |
| Isolation Resistance | > 5 MOhm (Input to Output, 500 Vdc) |
| PE Resistance | < 0.1 Ohm |
| UKCA | In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091 |
| Emission | (CE & RE) / Generic Standards: EN/BS EN 61000-6-3 CISPR 32, EN/BS EN 55032, KN 32, CISPR 11, EN/BS EN 55011, FCC Title 47: Class B |
|---|---|
| Immunity | Generic Standards: EN/BS EN 55024, KN 35, EN/BS EN 61000-6-2 |
| Harmonic Current Emissions | IEC/EN/BS EN 61000-3-2, Class A |
| Voltage Fluctuation and Flicker | IEC/EN/BS EN 61000-3-3 |
| Component Power Supply for General Use | EN/BS EN 61204-3 |
| Tags | Conformal Coating, Maritime |
|---|