Delta DRM-24V480W1PN 24V 20A 480W DIN Rail Power Supply, CliQ M Series

Brand
Delta
Model number
DRM-24V480W1PN

CliQ M DIN rail power supply with 24V 20A output (480W) from 85-276Vac or 88-375Vdc. Aluminium case and convection cooling, operating -25 to +70 °C. With power boost, a DC OK signal and maritime approvals.

Price and availability on request

Request a quote

Sent with the product details: Delta DRM-24V480W1PN 24V 20A 480W DIN Rail Power Supply, CliQ M Series.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Universal AC input voltage range
  • High power density in corrosion resistant aluminium casing
  • Power Boost of 150% up to 7 seconds
  • Advanced Power Boost (APB)
  • DNV GL and ABS approvals for maritime applications
  • Extreme low temperature cold start at -40°C
  • Built-in DC OK Contact and LED indicator for DC OK/ Overload
  • Conformal coating on PCBAs to protect against common dust and chemical pollutants
  • Certified according to IEC/EN/UL 62368-1

Specifications

Product
SeriesCliQ M Series
MountingDIN rail
Output
Output Current20A
Output Voltage24V
Output Voltage Adjustment Range24-28Vdc
Output Power480W
Line Regulation10mV Max. (@ 85-276Vac input, 100% load)
Load Regulation100mV Max. (@ 85-276Vac input, 0-100% load)
PARD100mVpp Max.
Start-up Time1000ms Max. @ 100Vac & 120Vac & 230Vac
Hold-up Time43ms Typ. @ 100Vac & 120Vac & 230Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 5% @ 0-100% load / Slew rate 0.1A/µs (@ 5Hz, 50Hz & 1kHz, 50% Duty Cycle)
Start-up with Capacitive Loads20,000µF Max.
Rise Time100ms Max. @ 100Vac & 120Vac & 230Vac (0µF, 24V, 20A) / 100ms Max. @ 100Vac & 120Vac & 230Vac (20,000µF, 24V, 20A)
Power Boost Duration5 seconds Typ. / 7 seconds Max.
Power Boost Recovery Time17 seconds Typ.
Input
Nominal Input Voltage100-240Vac
Input Voltage Range85-276Vac
Nominal Input Frequency50-60Hz
Input Frequency Range47-63Hz
Nominal DC Input Voltage110-300Vdc
DC Input Voltage Range88-375Vdc
Input Current5.11A Typ. @ 100Vac, 4.24A Typ. @ 120Vac, 2.29A Typ. @ 230Vac
Efficiency at 100% load93.37% Typ. @ 100Vac, 93.83% Typ. @ 120Vac, 94.17% Typ. @ 230Vac
Inrush Current13.0A Max. @ 100Vac & 120Vac & 230Vac
Power Factor at 100% load0.99 Typ. @ 100Vac, 0.99 Typ. @ 120Vac, 0.95 Typ. @ 230Vac
Leakage Current(Enclosure to Neutral) / < 0.31mA / 0.77mA @ 110Vac, 50Hz, TN/TT system / IT system / < 0.45mA / 1.13mA @ 132Vac, 50Hz, TN/TT system / IT system / < 0.80mA / 2.00mA @ 264Vac, 50Hz, TN/TT system / IT system
Power Dissipation0% load: / 5.29W Typ. @ 100Vac, 4.75W Typ. @ 120Vac, 2.84W Typ. @ 230Vac / 9.20W Max. @ 100Vac, 9.40W Max. @ 120Vac, 10.20W Max. @ 230Vac / / 100% load: / 34.08W Typ. @ 100Vac, 31.58W Typ. @ 120Vac, 29.70W Typ. @ 230Vac / 46.00W Max. @ 100Vac, 40.60W Max. @ 120Vac, 34.00W Max. @ 230Vac
Mechanical
Case Chassis / CoverAluminium
IndicatorGreen LED (DC OK) and Red LED (Overload)
Cooling SystemConvection
Input Terminal3 Pins (Rated 600V/35A)
Output Terminal6 Pins (Rated 300V/28A)
Noise Sound Pressure Level (SPL)< 25dBA
Mounting RailStandard TS35 DIN Rail in accordance with EN 60715
WireInput: AWG 18-8 / Output: AWG: 14-12
Unit Weight1.40 kg (3.09 lb)
Dimensions124 x 82 x 127 mm / 4.88” x 3.23” x 5.00”
Environment
Operating Temperature-25°C to +70°C (Cold start -40°C)
Storage Temperature-40°C to +85°C
Power De-ratingVertical Mounting: > 60°C de-rate power by 2.5% / °C / Horizontal Mounting: > 40°C de-rate power by 2.5% / °C
Operating Humidity5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, Half Sine Wave: 30G for a duration of 18ms; 3 times per direction, 6 times in total
Vibration (Non-Operating)IEC 60068-2-6, Sine Wave: 10-500Hz; 3G peak; displacement of 0.35mm; 60 min per axis for all X, Y, Z directions
Operating Altitude0 to 5,000 Meters (16,400 ft.) for ITE application / 0 to 2,500 Meters (8,200 ft.) for Industrial application
Pollution Degree2
Bump Test (Operating)IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total
Over Voltage CategoryIII / According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part)
Protections
Overvoltage28.8 – 35.2V, SELV Output, Hiccup Mode, / Non-Latching (Auto-Recovery)
Overload / Overcurrent> 150% of rated load current, Constant current limit, Auto-Recovery when the fault is removed
Over Temperature< 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery)
Short CircuitHiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Degree of ProtectionIP20
Protection Against ShockClass I with Primary Earth connection
Reliability
MTBF778,800 hrs. (I/P: 100Vac, O/P: 24V, 20A, Ta: 25°C) / 468,900 hrs. (I/P: 100Vac, O/P: 24V, 20A, Ta: 40°C)
Expected Cap Life Time131,400 hrs. @ 100Vac & 230Vac (O/P: 24V, 20A, Ta: 25°C) / 89,880 hrs. @ 100Vac (O/P: 24V, 20A, Ta: 40°C) / 103,300 hrs. @ 230Vac (O/P: 24V, 20A, Ta: 40°C) / 131,400 hrs. @ 100Vac & 230Vac (O/P: 24V, 10A, Ta: 40°C)
Safety
Electrical SafetySIQ Bauart: EN 62368-1, EN 61558-1, EN 61558-2-16, EN 61010-1, EN 61010-2-201 / UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) / CB scheme: IEC 60950-1, IEC 62368-1, IEC 61558-1, IEC 61558-2-16, IEC 61010-1, IEC 61010-2-201 / UKCA: BS EN 62368-1, BS EN 61558-1, BS EN 61558-2-16, BS EN 61010-1, BS EN 61010-2-201
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Galvanic IsolationInput / Output: 4.54 KVac / Input / PE: 2.5 KVac / Input / DC OK relay contact: 4.54 KVac (Recommend to connect DC OK pins together with output pins) / Output / PE: 1.5 KVac / Output / DC OK relay contact: 0.5 KVac / DC OK relay contact / PE: 1.5 KVac
Industrial Control EquipmentUL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355), / CSA: CSA C22.2 No. 107.1-01 (File No. 181564)
Electrical Equipments of MachinesEN/BS EN 60204-1 (over voltage category III)
Electrical Equipment for Use in Electrical Power InstallationsIEC/EN/BS EN 62477-1 / IEC 62103
Safety Entry Low VoltageSELV (IEC 60950-1)
MaritimeDNV GL: Germanischer Lloyd classified / ABS: American Bureau for Shipping) PDA Environmental category: C, EMC2
Isolation Resistance> 5 MOhm (Input to Output, 500 Vdc)
PE Resistance< 0.1 Ohm
UKCAIn conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091
EMC
Emission(CE & RE) / Generic Standards: EN/BS EN 61000-6-3 CISPR 32, EN/BS EN 55032, KN 32, CISPR 11, EN/BS EN 55011, FCC Title 47: Class B
ImmunityGeneric Standards: EN/BS EN 55024, KN 35, EN/BS EN 61000-6-2
Harmonic Current EmissionsIEC/EN/BS EN 61000-3-2, Class A
Voltage Fluctuation and FlickerIEC/EN/BS EN 61000-3-3
Component Power Supply for General UseEN/BS EN 61204-3
Other
TagsConformal Coating, Maritime

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.