Delta DRL-48V120W1AA 48V 2.5A 120W DIN Rail Power Supply, LYTE Series

Brand
Delta
Model number
DRL-48V120W1AA

LYTE DIN rail power supply with 48V 2.5A output (120W) from 85-264Vac or 120-375Vdc. Aluminium and steel case and convection cooling, operating -20 to +70 °C. With a constant-current mode, SEMI F47 compliance and conformal-coated boards.

Price and availability on request

Request a quote

Sent with the product details: Delta DRL-48V120W1AA 48V 2.5A 120W DIN Rail Power Supply, LYTE Series.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Universal AC input voltage
  • Built-in constant current circuit for reactive loads
  • Up to 90.0% efficiency
  • Full power from -10°C to +50°C operation at 230Vac @ 5000 meters or 16400 feet altitude
  • Built-in DC OK relay contact option available
  • Compliance to SEMI F47 @ 200Vac
  • Conformal coating on PCBAs to protect against common dust and chemical pollutants

Specifications

Product
SeriesLYTE Series
MountingDIN rail
Output
Output Current2.5A
Output Voltage48V
Output Voltage Adjustment Range44-56Vdc
Output Power120W
Line Regulation< 0.5% (@ 85-264Vac, 100% load)
Load Regulation< 1% (0-100% load)
PARD< 150mVpp @ > -10°C to +70°C / < 300mVpp @ ≤ -10°C to -20°C
Start-up Time200ms typ. @ 115Vac & 230Vac (100% load)
Hold-up Time20ms typ. @ 115Vac (100% load) / 90ms typ. @ 230Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 10% @ 85-264Vac input, 0-100% load (Slew Rate: 0.1A/μs)
Start-up with Capacitive Loads4,000µF Max
Rise Time30ms typ. @ nominal input (100% load)
Input
Nominal Input Voltage100-240Vac
Input Voltage Range85-264Vac
Nominal Input Frequency50-60Hz
Input Frequency Range47-63Hz
DC Input Voltage Range120-375Vdc
Input Current2.2A typ. @ 115Vac, 1.2A typ. @ 230Vac
Efficiency at 100% load89%typ.@115Vac, 90% typ.@ 230Vac
Inrush Current20A typ. @ 115Vac, 40A typ. @ 230Vac
Leakage Current< 0.25mA @ 264Vac
Power Dissipation0% load: : 1.21W @ 115Vac & 230Vac / 100% load: 13.3W @ 115Vac & 230Vac
Mechanical
Case Chassis / CoverSGCC / Aluminium
IndicatorGreen LED (DC OK)
Cooling SystemConvection
Input Terminal3 Pins (Rated 600V/35A)
Output Terminal6 Pins (Rated 300V/28A)
Signal Terminal6 Pins (Rated 300V/28A)
Noise Sound Pressure Level (SPL)< 25dBA
Mounting RailStandard TS35 DIN Rail in accordance with EN 60715
WireInput: AWG 18-8 / Output: AWG 22-12 / Signal: AWG 24-12
Unit Weight0.54 kg (1.19 lb)
Dimensions123.6 x 40 x 117.6 mm / 4.87” x 1.57” x 4.63”
Environment
Vibration (Operating)IEC 60068-2-6, Sine Wave: 10Hz to 500Hz @ 19.6m/s² (2G peak); displacement of 0.35mm; 10 min per cycle, 60 min for X direction
Shock Test (Operating)IEC 60068-2-27, 27, Half Sine Wave: 10G for duration of 11ms; 1 time in X axis
Operating Temperature-20°C to +70°C
Storage Temperature-40°C to +85°C
Power De-rating-10°C to -20°C de-rate power by 2%/°C / > 40°C de-rate power by 1.67% / °C @ 115Vac / > 50°C de-rate power by 2.5% / °C @ 230Vac / < 100Vac de-rate power by 1% / Vac
Operating Humidity5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, 27, Half Sine Wave: 50G for duration of 11ms; 3 times per direction, 9 times in total
Vibration (Non-Operating)IEC 60068-2-6, Random: 5Hz to 500Hz; 2.09Grms; 20 min per axis for all X, Y, Z directions
Operating Altitude0 to 5,000 Meters (16,400 ft.)
Pollution Degree2
Protections
Overvoltage57.0V-67.2V, SELV Output, Latch Mode
Overload / Overcurrent105-150% of rated load current, Continuous current
Over TemperatureLatch Mode
Short CircuitHiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Degree of ProtectionIP20
Protection Against ShockClass I with Primary Earth connection
Reliability
MTBFTelcordia SR-332: > 700,000 hrs / I/P: 100Vac, O/P: 100% load, Ta: 25°C
Expected Cap Life Time10 years (115Vac & 230Vac, 50% load @ 40°C)
Safety
Electrical SafetyTUV Bauart: EN 60950-1, EN 62368-1 / UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881) / CB scheme: IEC 60950-1, IEC 62368-1
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Galvanic IsolationInput to Output: 3.0KVac / Input to Ground: 2.0KVac / Output to Ground: 0.5KVac
Safety Entry Low VoltageSELV
UKCAIn conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016
EMC
Emission(CE & RE) / Generic Standards: EN/BS EN 61000-6-3, EN/BS EN 61000-6-4 / CISPR 32, EN/BS EN 55032, EN/BS EN 55011, FCC Title 47: Class B; GB9254.1
ImmunityGeneric Standards: EN/BS EN 61000-6-1, EN/BS EN 61000-6-2, EN/BS EN 55024
Harmonic Current EmissionsIEC/EN/BS EN 61000-3-2, Class A; GB17625.1
Voltage Fluctuation and FlickerIEC/EN/BS EN 61000-3-3
Component Power Supply for General UseEN/BS EN 61204-3

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.