Delta DRL-24V480W3EN 24V 20A 480W 3-Phase DIN Rail Power Supply, DIN Eco Series
- Brand
- Delta
- Model number
- DRL-24V480W3EN
- Category
- DIN-Rail Power Supplies
DIN Eco DIN rail power supply with 24V 20A output (480W) from 3 x 340-575 Vac. Aluminium case and convection cooling, operating -40 to +70 °C. With SEMI F47 compliance.
Price and availability on request
Key features
- 3-Phase AC input from 340-575 Vac
- Optional 3ENA models: 600 Vac with conformal coating
- Slim and compact size design
- Wide operating temperature from -40°C to +70°C
- Power good LED indicator
- Surge protection capacity 4 kV / 2 kV
- Compliant with SEMI F47
- IEC/EN/UL 62368-1 and IEC/UL 61010-1 certified
Specifications
| Series | DIN Eco Series |
|---|---|
| Mounting | DIN rail |
| Output Current | 20A |
|---|---|
| Output Voltage | 24V |
| Output Voltage Adjustment Range | 24-28 Vdc |
| Output Power | 480W |
| Line Regulation | ± 0.5% |
| Load Regulation | ± 1% |
| PARD | < 100 mVpp typ. @ 0°C to +70°C / < 300 mVpp typ. @ -30°C to 0°C |
| Start-up Time | 1200 ms typ. @ nominal input (100% load) |
| Hold-up Time | 20 ms typ. @ 3 x 400 Vac & 3 x 500 Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 10% @ 3 x 340-600 Vac input, 10-100% load (Slew Rate: 2.5 A/μS, 50% duty cycle @ 5 Hz & 10 kHz) |
| Start-up with Capacitive Loads | 20,000 µF Max |
| Rise Time | 15 ms typ. @ nominal input (100% load) |
| Nominal Input Voltage | 3 x 380-500 Vac |
|---|---|
| Input Voltage Range | 3 x 340-575 Vac (3-Phase) or 2 x 340-575 Vac (2-Phase) |
| Nominal Input Frequency | 50-60 Hz |
| Input Frequency Range | 47-63Hz |
| Input Current | < 0.82 A @ 3 x 400 Vac, / < 0.67 A @ 3 x 500 Vac |
| Efficiency at 100% load | 94% typ. @ 3 x 400 Vac & 3 x 500 Vac |
| Inrush Current | 15 A typ. @ 3 x 400 Vac & 3 x 500 Vac |
| Power Factor at 100% load | > 0.9 typ. @ 3 x 400 Vac, > 0.91 typ. @ 3 x 500 Vac |
| Leakage Current | < 1.5 mA @ 3 x 400 Vac & 3 x 500 Vac |
| Case Chassis / Cover | Aluminium |
|---|---|
| Indicator | Green LED DC OK |
| Cooling System | Convection |
| Input Terminal | 4 Pins (Rated 600 V / 30 A) |
| Output Terminal | 4 Pins (Rated 600 V / 30 A) |
| Signal Terminal | 2 Pins (Rated 300 V / 7 A) |
| Noise Sound Pressure Level (SPL) | < 25 dBA |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Wire | Input: AWG 18-10 / Output: AWG 12-10 / Signal: AWG 22-18 |
| Unit Weight | 0.95 kg (2.09 lb) |
| Dimensions | 123.6 x 60 x 142.6 mm / 4.87” x 2.36” x 5.61” |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 10 Hz to 500 Hz @ 19.6 m/s² (2 G peak); 10 min per cycle, 60 min for X, Y, Z direction. |
|---|---|
| Operating Temperature | -40°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Power De-rating | > 50°C de-rate power by 2.5 % / °C |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction, 9 times in total |
| Vibration (Non-Operating) | IEC 60068-2-6, Random: 5 Hz to 500 Hz (2.09 G); 20 min per axis for all X, Y, Z direction |
| Operating Altitude | 0 to 5,000 Meters (16,400 ft.) |
| Pollution Degree | 2 |
| Over Voltage Category | II (Compliance to EN 62477-1 OVC III with 2,000 meters altitude) |
| Overvoltage | < 34 V, SELV Output, Auto-recovery Mode |
|---|---|
| Overload / Overcurrent | 105 – 170% of rated load current, Auto-recovery (150% Power Boost for 500 ms ) |
| Over Temperature | Non-Latching (Auto-recovery) |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-recovery when the fault is removed) |
| Degree of Protection | IP20 |
| Protection Against Shock | Class I with Primary Earth connection |
| MTBF | Telcordia SR-332: > 700,000 hrs. / I/P: 3 x 400 Vac & 3 x 500 Vac, O/P: 100% load, Ta: 25°C |
|---|---|
| Expected Cap Life Time | 10 Years / I/P: 3 x 400 Vac & 3 x 500 Vac, O/P: 50% load, Ta: 40°C |
| Electrical Safety | TUV Bauart: IEC/EN 62368-1 / UL/cUL: UL 62368-1, CSA C22.2; UL 61010-1/-2-201, CAN/CSA-C22.2 No. 61010-1-12 / CB scheme: IEC/EN/BS EN 62368-1, AS/NZS 62368-1; IEC/EN 61010-1/-2-201 / CCC: GB4943.1 / BIS: IS 13252-1 (Part 1) / BSMI: CNS15598-1 / EAC: TP TC 004/2011 / KC: KC 62368-1 (upon request) |
|---|---|
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| Galvanic Isolation | Input to Output: 4.0 kVac / Input to Ground: 2.5 kVac / Output to Ground: 0.5 kVac / DC OK relay contact to Output: 0.5 kVac |
| Safety Entry Low Voltage | SELV (IEC/EN 61010-1/2-201, IEC/EN 62368-1) |
| UKCA | In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091 |
| Emission | (CE & RE) / Generic Standards: CISPR 32, EN/BS EN 55032, AS/NZS CISPR 32, Class B; KS C 9832; CNS15936; EN/EN BS 61000-6-4, EN/BS EN 61204-3; Compliance to FCC Title 47 |
|---|---|
| Immunity | Generic Standards: EN/BS EN 55035; KS C 9835; EN/BS EN 61000-6-2 ; EN/BS EN 61204-3 |
| Harmonic Current Emissions | IEC/EN/EN BS 61000-3-2, Class A |
| Voltage Fluctuation and Flicker | IEC/EN/EN BS 61000-3-3, dmax ≤ 4% |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.