Delta DRL-24V120W1ENA 24V 5A 120W DIN Rail Power Supply, LYTE II Series
- Brand
- Delta
- Model number
- DRL-24V120W1ENA
- Category
- DIN-Rail Power Supplies
LYTE II DIN rail power supply with 24V 5A output (120W) from 90-264Vac. Aluminium and steel case and convection cooling, operating -40 to +70 °C. With a constant-current mode and SEMI F47 compliance.
Price and availability on request
Key features
- Universal AC input voltage range
- Built-in constant current circuit for reactive loads
- High power density
- Operate from -40°C to +70°C
- Reduced no-load power consumption
- Compliance with DOE VI Energy Standard
- Compliance to SEMI F47 @ 200Vac
Specifications
| Series | LYTE II Series |
|---|---|
| Mounting | DIN rail |
| Output Current | 5A |
|---|---|
| Output Voltage | 24V |
| Output Voltage Range | 21.6-26.4Vdc |
| Output Voltage Adjustment Range | 21.6-26.4Vdc |
| Output Power | 120W |
| Line Regulation | ± 0.5% @ 115Vac & 230Vac |
| Load Regulation | ± 0.5% |
| PARD | < 150mp @ 0°C to +7Vp0°C / < 450mVpp @ -30°C to 0°C |
| Start-up Time | 500ms typ. @ 115Vac & 230Vac |
| Hold-up Time | 10ms typ. @ 115Vac (100% load) / 16ms typ. @ 230Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 10% @ 115Vac & 230Vac input, 10-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 5Hz & 10KHz) |
| Start-up with Capacitive Loads | 8,000µF Max |
| Rise Time | 30ms typ. @ 115Vac & 230Vac |
| Nominal Input Voltage | 100-240Vac |
|---|---|
| Input Voltage Range | 90-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Input Current | 2.1A typ. @ 115Vac, 1.3A typ. @ 230Vac |
| Efficiency at 100% load | 88.5% typ.@ 230Vac |
| Inrush Current | 35A typ. @ 230Vac |
| Leakage Current | < 0.5mA @ 240Vac |
| Case Chassis / Cover | Aluminum / SGCC |
|---|---|
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Input Terminal | 3 Pins (Rated 300V/30A) |
| Output Terminal | 4 Pins (Rated 300V/20A) |
| Noise Sound Pressure Level (SPL) | < 25dBA |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Unit Weight | 0.45 kg (0.99 lb) |
| Dimensions | 123.6 x 30 x 116.8 mm / 4.87” x 1.18” x 4.60” |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 10Hz to 500Hz @ 19.6 m/s² (2G peak); 10 min per cycle, 60 min for X direction |
|---|---|
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for duration of 11ms; 1 time in X axis |
| Operating Temperature | -40°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Power De-rating | > 40°C de-rate power by 1.67 % / °C @115Vac / > 50°C de-rate power by 2.5 % / °C @230Vac |
| Operating Humidity | 20 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 50G for duration of 11ms; 3 times per direction, 9 times in total |
| Vibration (Non-Operating) | IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction |
| Operating Altitude | 0 to 5,000 Meters (16,400 ft.) |
| Pollution Degree | 2 |
| Over Voltage Category | II (Compliance to EN 62477-1 OVC III with 2000 meters altitude) |
| Overvoltage | <33.6V, SELV Output, Latch Mode |
|---|---|
| Overload / Overcurrent | 105 - 150% of rated load current, Auto-recovery / Continuous current limit Mode*5 (Vo>80%) |
| Over Temperature | Latch Mode |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Protection Against Shock | Class I with Primary Earth6 connection |
| Internal Fuse | T4 A / 250 V |
| MTBF | > 700,000 hrs. as per Telcordia SR-332 / I/P: 115Vac & 230Vac, O/P: 100% load, Ta: 25°C |
|---|---|
| Expected Cap Life Time | 10 years (230Vac, 50% load @ 40°C) |
| Electrical Safety | CB scheme: IEC 62368-1, IEC 61010-1 & -2-201 TUV Bauart: EN 62368-1, EN 61010-1 & -2-201 / UL/cUL: UL 62368-1, UL 61010-1 & -2-201 / CCC: GB4943.1 / BSMI: CNS14336-1 / EAC: TP TC 004/2011 / KC: K 60950-1 |
|---|---|
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| UKCA | In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016 |
| Emission | (CE & RE) / CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, AS/NZS CISPR32, EN/BS EN 61204-3, KN 32 / Compliance to FCC Title 47, EN/BS EN 61000-6-3: Class B |
|---|---|
| Immunity | EN/BS EN 55035, KN 35, EN/BS EN 61000-6-2 / Compliance to EN/BS EN 61000-6-1 |
| Harmonic Current Emissions | IEC/EN/BS EN 61000-3-2, Class A |
| Voltage Fluctuation and Flicker | IEC/EN/BS EN 61000-3-3 |
| ESD Immunity | IEC 61000-4-2 |
| Radiated Immunity | IEC 61000-4-3 |
| EFT | IEC 61000-4-4 |
| Surge | IEC 61000-4-5 |
| Conducted Immunity | IEC 61000-4-6 |
| Magnetic Field | IEC 61000-4-8 |
| Voltage Dips | IEC 61000-4-11 |
| Component Power Supply for General Use | EN/BS EN 61204-3 |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.