Force-GT DIN rail power supply with 48V 10A output (480W) from 3 x 320-575 Vac or 450-800 Vdc. Aluminium case and convection cooling, operating -40 to +70 °C. With a constant-current mode, a DC OK signal and conformal-coated boards.

Price and availability on request

Request a quote

Sent with the product details: Delta DRF-48V480W3GBA 48V 10A 480W 3-Phase DIN Rail Power Supply, Force-GT Series.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Universal AC input voltage range
  • Built-in constant current circuit for charging applications
  • Full load operating temperature up to 55°C
  • Cold start at -40°C
  • Ultra-Slim design
  • Reduced no-load power consumption
  • Built-in DC OK relay and LED indicator
  • Conformal coating on PCBAs to protect against common dust and pollutants

Specifications

Product
SeriesForce-GT Series
MountingDIN rail
Output
Output Current10A
Output Voltage48V
Output Voltage Adjustment Range48-56 Vdc
Output Power480W
Line Regulation< 80 mV (@ 3 x 320-575 Vac input, 100% load)
Load Regulation< 280 mV (@ 3 x 320-575 Vac input, 0-100% load)
PARD< 175 mVpp
Start-up Time1,000 ms typ. @ nominal input (100% load)
Hold-up Time20 ms typ. @ 3 x 400 Vac & 500 Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 5% @ 3 x 320-575 Vac input, 10-100% load (Slew Rate: 0.1 A/μs, 50% duty cycle @ 5 Hz to 1 kHz)
Start-up with Capacitive Loads20,000 µF Max
Rise Time100 ms typ. @ nominal input (100% load)
Input
Nominal Input Voltage3 x 380-500 Vac
Input Voltage Range3 x 320-575 Vac (3-Phase) or 2 x 340-575 Vac (2-Phase)
Nominal Input Frequency50-60 Hz
Input Frequency Range47-63Hz
DC Input Voltage Range450-800 Vdc
Input Current< 0.85 A @ 3 x 400 Vac, / < 0.73 A @ 3 x 500 Vac
Efficiency at 100% load95.5% typ. @ 3 x 400 Vac & 500 Vac
Inrush Current35 A typ. @ 3 x 400 Vac & 3 x 500 Vac
Power Factor at 100% load> 0.90 @ 3 x 400 Vac, / > 0.88 @ 3 x 500 Vac
Leakage Current< 3.5 mA @ 3 x 500 Vac
Power Dissipation0% load: < 7.0 W @ 3 x 400 Vac & 3 x 500 Vac / 100% load: < 33.0 W @ 3 x 400 Vac & 3 x 500 Vac
Mechanical
Case Chassis / CoverAluminum
IndicatorGreen LED DC OK
Cooling SystemConvection
Input Terminal4 Pins (Rated 600 V / 30 A)
Output Terminal4 Pins (Rated 600 V / 30 A)
Signal Terminal2 Pins (Rated 300 V / 12 A)
Noise Sound Pressure Level (SPL)< 25dBA
Mounting RailStandard TS35 DIN Rail in accordance with EN 60715
WireInput: AWG 18-10 / Output: AWG 12-10 / DC OK: AWG 20-16
Unit Weight1.20 kg (2.65 lb)
Dimensions124 x 65 x 127.3 mm / 4.88” x 2.56” x 5.01”
Environment
Vibration (Operating)IEC 60068-2-6, Sine Wave: 10-500 Hz; 3G peak; 60 min per axis for all X, Y, Z directions
Operating Temperature3-Phase / -40°C to +70°C / 2-Phase / -40°C to +60°C
Storage Temperature-40°C to +85°C
Power De-ratingVertical Mounting: > 55°C de-rate power by 3.33% / °C / Horizontal Mounting: > 25°C de-rate power by 2.5% / °C / Input Voltage: / 2-Phase / 2 x 340-575 Vac de-rate power to 80%
Operating Humidity5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction
Operating AltitudeOVC III / 0 to 2,500 Meters (8,200 ft.) / OVC II / 2,500 to 6,000 Meters (19,680 ft.) / 0 to 5,000 Meters (16,400 ft.)
Pollution Degree2
Over Voltage CategoryIEC/EN 62477-1, EN 60204-1, IEC 62103 / OVC III: 0 to 2,500 Meters (8,200 ft.) / OVC II: 2,500 to 6,000 Meters (19,680 ft.) / IEC/EN 62368-1, IEC/EN 61010 / OVC II: 0 to 5,000 Meters (16,400 ft.)
Protections
Overvoltage< 35 V, Hiccup Mode, Non-Latching (Auto-Recovery)
Overload / Overcurrent110 - 150% of rated load current, Auto-recovery / Continuous current limit Mode (Vo > 18Vdc)
Over Temperature60°C-80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery)
Short CircuitHiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Degree of ProtectionIP20
Protection Against ShockClass I with Primary Earth connection
Reliability
MTBFTelcordia SR-332: > 600,000 hrs. / I/P: 3 x 400 Vac & 3 x 500 Vac, O/P: 100% load, Ta: 25°C
Expected Cap Life Time10 Years / I/P: 3 x 400 Vac & 3 x 500 Vac, O/P: 50% load, Ta: 40°C
Safety
Electrical SafetySIQ Bauart: EN 62368-1, EN 61010-1, EN 61010-2-201 / UL/cUL recognized: UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) / CB scheme: IEC 60950-1, IEC 62368-1, IEC 61010-1, IEC 61010-2-201 / UKCA: BS EN 62368-1, BS EN 61010-1, BS EN 61010-2-201 / EAC: TP TC 004/2011 / BIS: IS 13252 (Part 1)
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Galvanic IsolationInput to Output: 4.0 kVac / Input to Ground: 2.0 kVac / Output to Ground: 1.5 kVac / DC OK relay contact to Output: 0.5 kVac / DC OK relay contact to Ground: 1.5 kVac
Electrical Equipments of MachinesEN/BS EN 60204-1 (over voltage category III)
Electrical Equipment for Use in Electrical Power InstallationsIEC/EN/BS EN 62477-1 / IEC 62103
Safety Entry Low VoltageSELV (IEC 60950-1)
UKCAIn conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091
Electrical Equipment for Measurement, Control, and Laboratory UseUL 61010-1, UL 61010-2-201 (File No. E315355)
EMC
Emission(CE & RE) / Generic Standards: EN/BS EN 61000-6-3, CISPR 32, EN/BS EN 55032, KS C 9832, FCC Title 47: Class B
ImmunityGeneric Standards: EN/BS EN 55024, EN/BS EN 55035, KS C 9835, EN/BS EN 61000-6-1
Harmonic Current EmissionsIEC/EN/BS EN 61000-3-2, Class A
Voltage Fluctuation and FlickerIEC/EN/BS EN 61000-3-3
Component Power Supply for General UseEN/BS EN 61204-3