Delta DRF-24V240W1GBA 24V 10A 240W DIN Rail Power Supply, Force-GT Series

Brand
Delta
Model number
DRF-24V240W1GBA

Force-GT DIN rail power supply with 24V 10A output (240W) from 90-264 Vac or 127-375 Vdc. Metal case and convection cooling, operating -40 to +70 °C. With a constant-current mode, a DC OK signal and conformal-coated boards.

Price and availability on request

Request a quote

Sent with the product details: Delta DRF-24V240W1GBA 24V 10A 240W DIN Rail Power Supply, Force-GT Series.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Surge capacity (with SPD) up to 6 kV
  • Compliant with IEC 61000-4-6 at 20 V for semiconductor requirements
  • Universal AC input voltage range
  • Built-in constant current circuit for charging applications
  • Full load operating temperature up to 60°C
  • Ultra-Slim design
  • Long life electrolytic capacitor
  • Built-in DC OK relay and LED indicator
  • Conformal coating on PCBAs to protect against common dust and pollutants
  • Compliant with 80 PLUS Gold for 115 V Industrial

Specifications

Product
SeriesForce-GT Series
MountingDIN rail
Output
Output Current10A
Output Voltage24V
Output Voltage Adjustment Range24-28 Vdc
Output Power240W
Line Regulation± 0.5% @ 115 Vac & 230 Vac
Load Regulation± 0.5%
PARD< 100 mVpp @ 0°C to +70°C / < 300 mVpp @ -30°C to 0°C
Start-up Time500 ms typ. @ 115 Vac & 230 Vac
Hold-up Time30 ms typ. @ 115 Vac & 230 Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 10% @ 115 Vac & 230 Vac input, 10-100% load (Slew Rate: 2.5 A/μS, 50% duty cycle @ 5 Hz & 10 kHz)
Start-up with Capacitive Loads10,000 µF Max
Rise Time30 ms typ. @ 115 Vac & 230 Vac
Input
Nominal Input Voltage100-240 Vac
Input Voltage Range90-264 Vac
Nominal Input Frequency50-60 Hz
Input Frequency Range47-63Hz
DC Input Voltage Range127-375 Vdc
Input Current2.5 A typ. @ 115 Vac, 1.3 A typ. @ 230 Vac
Input Power (Standby Mode)0.5 W max @ 115 Vac & 230 Vac
Efficiency at 100% load94.5 typ. @ 230 Vac
Inrush Current40 A typ. @ 230 Vac
Power Factor at 100% load> 0.96 @ 115 Vac & > 0.93 @ 230 Vac
Leakage Current< 0.5 mA @ 240 Vac
Mechanical
Case Chassis / CoverMetal
IndicatorGreen LED DC OK
Cooling SystemConvection
Input Terminal3 Pins (Rated 600 V / 30 A)
Output Terminal4 Pins (Rated 600 V / 30 A)
Signal Terminal2 Pins (Rated 300 V / 6 A)
Noise Sound Pressure Level (SPL)< 25 dBA
Mounting RailStandard TS35 DIN Rail in accordance with EN 60715
WireInput: AWG 18-12 / Output: AWG 18-12 / DC OK: AWG 22-16
Unit Weight0.64 kg (1.41 lb)
Dimensions123.6 x 40 x 116.8 mm / 4.87” x 1.57” x 4.60”
Environment
Vibration (Operating)IEC 60068-2-6, Sine Wave: 10 Hz to 500 Hz; 4 G peak; 60 min per axis for all X, Y, Z directions
Operating Temperature-40°C to +70°C
Storage Temperature-40°C to +85°C
Power De-ratingTemperature: > 60°C de-rate power by 2.5 % / °C / Input Voltage: < 100 Vac de-rate power by 1% / Vac
Operating Humidity5 to 90% RH (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction
Operating Altitude0 to 5,000 Meters (16,400 ft.)
Pollution Degree2
Over Voltage CategoryII (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
Protections
Overvoltage<34 V, SELV Output, Latch Mode
Overload / Overcurrent105 - 150% of rated load current, Auto-recovery / Continuous current limit Mode (Vo > 80%)
Over TemperatureLatch Mode
Short CircuitHiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Protection Against ShockClass I with Primary Earth connection
Internal FuseT4 A / 250 V
Reliability
MTBFTelcordia SR-332: > 700,000 hrs / I/P: 115 Vac & 230 Vac, O/P: 100% load, Ta: 25°C
Expected Cap Life Time10 years (115 Vac & 230 Vac, 50% load @ 50°C)
Safety
Electrical SafetyCB scheme: IEC 62368-1, IEC 60950-1, IEC 61010-1/-2-201 / TUV Bauart: EN/BS EN 62368-1, EN/BS EN 61010-1/-2-201 / UL/cUL: UL 62368-1, UL 61010-1/-2-201 / EAC: TP TC 004/2011 / BSMI: CNS14336-1 / CCC: GB4943.1
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Galvanic IsolationInput to Output: 4.0 kVac / Input to Ground: 2.0 kVac / Output to Ground: 1.5 kVac / Output to DC OK: 500 Vac
UKCAIn conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016
EMC
Emission(CE & RE) / CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, AS/NZS CISPR 32, EN/BS EN 61204-3, KS C 9832 / Compliance to FCC Title 47, EN 61000-6-3: Class B
ImmunityEN/BS EN 55035, KS C 9835, EN/BS EN 61000-6-2 Compliance to EN 61000-6-1
Harmonic Current EmissionsIEC/EN/BS EN 61000-3-2, Class A & Class D
Voltage Fluctuation and FlickerIEC/EN/BS EN 61000-3-3
Component Power Supply for General UseEN/BS EN 61204-3

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.